Abstract

The Modulation Transfer Function (MTF) of any system is the frequency response to a delta signal. This response is degraded by several factors such as the inherent veiling glare of the detector and the focal spot size among others. Consequently, the MTF has been one of the physical characteristics that are commonly used to quantitatively measure the physical performance of a system. In this article, the MTF of two flat panel detectors (FPD) and of two Cone Beam CT systems is evaluated. First, the MTF of PaxScan 2520 and of PaxScan 4030CB is evaluated. One of the standard techniques to evaluate the MTF of a FPD is by using an edge of a metal with high atomic number. For instance, it has been suggested by IEC 62220-1 to use an opaque edge to evaluate the MTF of a FPD. Yet, it was found that different metals yield slightly different MTF. In this study, the effects on the MTF evaluation of different metals and exposure parameters was studied and analyzed. First, the MTF was evaluated using different kVps and exposures levels. Second, the MTF was evaluated using aluminum edges of different thickness. Third, the MTF was evaluated using the following four different metals: Aluminum, Copper, Steel and Lead. Finally, the MTF obtained previously were compared to the MTF obtained by using a pinhole. In the second part of this study, the MTF of two systems using these two FPDs were also evaluated using different wires, filters and acquisition modes. The preliminary results demonstrate that the MTF is independent of kVp and exposure level. Yet, it is dependent on the material used to evaluate it.

Similar Papers
  • Research Article

Evaluation of parallactic unsharpness caused by flat panel detector in digital radiography

  • Dec 10, 2010
  • Chinese journal of radiology
  • Liu Chuanya +3
  • Conference Article
  • Citations4

High spatial resolution performance of pixelated scintillators

  • Mar 09, 2017
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Kazuki Shigeta +7
  • Research Article
  • Citations6

FPDシステムにおけるリサンプリングが基本的な画質特性の測定に及ぼす影響

  • Jan 01, 2007
  • Japanese Journal of Radiological Technology
  • Reiji Katayama +7
  • Conference Article
  • Citations49

DQE of direct and indirect digital radiography systems

  • Jun 28, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Ehsan Samei +3
  • Research Article
  • Citations14

Technical Note: An oversampling procedure to calculate the MTF of an imaging system from a bar-pattern image.

  • Sep 23, 2016
  • Medical Physics
  • Antonio González‐López +2
  • Conference Article
  • Citations9

Characterization of a prototype tabletop x-ray CT breast imaging system

  • Mar 08, 2007
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • J Michael O'Connor +4
  • Research Article

Modulation transfer function (MTF) and noise power spectrum (NPS) studies on three industrial digital radiography (IDR) systems

  • Jun 01, 2009
  • Insight - Non-Destructive Testing and Condition Monitoring
  • K A Mohd Salleh +2
  • Research Article
  • Citations75

Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system.

  • Apr 01, 2000
  • Investigative radiology
  • MARTIN SPAHN +6
  • Research Article
  • Citations37

Accurate MTF measurement in digital radiography using noise response.

  • Jan 22, 2010
  • Medical Physics
  • Andrew Kuhls-Gilcrist +4
  • Research Article
  • Citations22

Signal detection and location‐dependent noise in cone‐beam computed tomography using the spatial definition of the Hotelling SNR

  • May 17, 2012
  • Medical Physics
  • Claudia C Brunner +3
  • Conference Article
  • Citations32

Dual energy imaging with a dual-layer flat panel detector

  • Mar 04, 2019
  • Medical Imaging 2019: Physics of Medical Imaging
  • Minghui Lu +6
  • Research Article
  • Citations26

Characterization and application of a GE amorphous silicon flat panel detector in a synchrotron light source

  • Aug 12, 2007
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • J.H Lee +11
  • Conference Article
  • Citations18

Investigation of imaging performance of amorphous selenium flat-panel detectors for digital mammography

  • Jun 28, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Wei Zhao +3
  • Research Article
  • Citations5

Prediction of detectability of the mandibular canal by quantitative image quality evaluation using cone beam CT.

  • Feb 13, 2018
  • Dentomaxillofacial Radiology
  • Yohei Takeshita +8
  • Research Article
  • Citations2

直接型および間接型Flat Panel Detectorsと Computed Radiographyにおける物理的画質評価を利用した画質同一化の試み

  • Jan 01, 2011
  • Japanese Journal of Radiological Technology
  • Tomohiro Yokoi +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.