• Home
  • Search
  • An automatic and accurate registration method for electro-anatomical map and CT surface.
  • Cite Icon3
  • https://doi.org/10.1002/rcs.1818Copy DOI Icon

An automatic and accurate registration method for electro-anatomical map and CT surface.

  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Electro-anatomical maps (EAM) and CT surface registration are widely used for catheter navigation in atrial fibrillation ablations. However, few studies have investigated the registration algorithm. Moreover, some of them are semiautomatic, so that physicians must be proficient; some are inaccurate for catheter navigation. A both automatic and accurate registration method is needed. A Hausdorff distance based approach (HD) was proposed for EAM/CT registration. First, using principal axes based registration, EAM/CT pairs were coarsely aligned. Then, using Hausdorff distance as the fine objective function, EAM/CT pairs were finely aligned. Six real EAM/CT pairs were collected from five patients and 38 simulated pairs were generated. Each pair was aligned using Carto-Merge, a stochastic approach (SA) and HD. Considering the balance of operability, accuracy and robustness, HD obtained the best EAM/CT registration results among the three approaches. Experiments validate that the proposed method registers EAM and CT surface both automatically and accurately.

Similar Papers
  • Research Article
  • Citations18

Automatic registration method for multisensor datasets adopted for dimensional measurements on cutting tools

  • Feb 22, 2013
  • Measurement Science and Technology
  • L Shaw +4
  • Research Article
  • Citations16

Automatic Registration between Real-Time Ultrasonography and Pre-Procedural Magnetic Resonance Images: A Prospective Comparison between Two Registration Methods by Liver Surface and Vessel and by Liver Surface Only

  • Apr 13, 2016
  • Ultrasound in Medicine & Biology
  • Ah Yeong Kim +15
  • Conference Article
  • Citations2

A robust registration method for high resolution remote sensing images

  • Oct 31, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yingdan Wu +1
  • Research Article

YIA Abstracts: Best abstracts on clinical studies

  • Jun 01, 2009
  • Europace
  • Christian Veltmann +20
  • Research Article
  • Citations1

Atrial tissue characterisation using electroanatomic voltage mapping and cardiac magnetic resonance imaging

  • May 19, 2022
  • EP Europace
  • I Sim +12
  • Research Article

Optimization of Outflow-Tract Ventricular Arrhythmia Ablation Using a Universal Right Ventricle Model

  • Aug 24, 2025
  • Journal of Cardiovascular Development and Disease
  • Krystian Szkoła +5
  • Research Article
  • Citations16

Intracardiac echocardiography for registration of rotational angiography-based left atrial reconstructions: a novel approach integrating two intraprocedural three-dimensional imaging techniques in atrial fibrillation ablation

  • Jan 28, 2011
  • Europace
  • G Nolker +7
  • Research Article

Fluoroscopy-free catheter ablation for right-sided accessory pathways: Feasibility, safety, and outcomes.

  • May 13, 2025
  • Kardiologia polska
  • Dariusz Rodkiewicz +7
  • Research Article

493 Prognostic value of myocardial scar and chamber enlargement at electroanatomical mapping during catheter ablation in adult congenital heart disease

  • Dec 08, 2021
  • European Heart Journal Supplements
  • Francesco Perna +9
  • Supplementary Content
  • Citations14

Advancements in Imaging for Atrial Fibrillation Ablation: Is There a Potential to Improve Procedural Outcomes?

  • Jul 01, 2020
  • The Journal of Innovations in Cardiac Rhythm Management
  • Edmond Obeng-Gyimah +1
  • Research Article
  • Citations7

Automatic registration and precise tumour localization method for robot-assisted puncture procedure under inconsistent breath-holding conditions.

  • Aug 25, 2021
  • The International Journal of Medical Robotics and Computer Assisted Surgery
  • Long Lei +6
  • Research Article
  • Citations20

An automatic 3D point cloud registration method based on regional curvature maps

  • Oct 27, 2016
  • Image and Vision Computing
  • Junhua Sun +2
  • Research Article
  • Citations1

Atrial fibrillation ablation guided with electroanatomical mapping system: A one year follow up

  • Aug 01, 2010
  • Medical Journal of Indonesia
  • Yoga Yuniadi +3
  • Research Article
  • Citations23

Electroanatomic mapping systems (CARTO/EnSite NavX) vs. conventional mapping for ablation procedures in a training program.

  • Nov 12, 2015
  • Journal of Interventional Cardiac Electrophysiology
  • Jorge Romero +11
  • Research Article
  • Citations4

Automatic 3D Registration of CT-MR Head and Neck Images With Surface Matching

  • Jan 01, 2019
  • IEEE Access
  • Qin Chu +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.