• Home
  • Search
  • Automatic dose reduction should not mask needs for individual dose reduction.
  • Cite Icon2
  • https://doi.org/10.1148/radiol.2331040545Copy DOI Icon

Automatic dose reduction should not mask needs for individual dose reduction.

  • Oct 1, 2004
  • Radiology
  • Jean-François Paul +2 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

HomeRadiologyVol. 233, No. 1 PreviousNext Letters to the EditorAutomatic Dose Reduction Should Not Mask Needs for Individual Dose ReductionJean-François Paul, Hicham T. Abada, Anne B. Sigal-CinqualbreJean-François Paul, Hicham T. Abada, Anne B. Sigal-CinqualbreAuthor AffiliationsHôpital Marie Lannelongue, 133 Avenue de la Résistance, Plessis-Robinson 92350, France.* Hôpital René Dubos, Cergy-pontoise, France† e-mail: [email protected]Jean-François PaulHicham T. AbadaAnne B. Sigal-CinqualbrePublished Online:Oct 1 2004https://doi.org/10.1148/radiol.2331040545MoreSectionsFull textPDF ToolsImage ViewerAdd to favoritesCiteTrack CitationsPermissionsReprints ShareShare onFacebookTwitterLinked In References 1 Mastora I, Remy-Jardin M, Delannoy V, et al. Multi–detector row spiral CT angiography of the thoracic outlet: dose reduction with anatomically adapted online tube current modulation and preset dose savings. Radiology 2004; 230:116-124. Link, Google Scholar2 The ALARA (as low as reasonably achievable) concept in pediatric CT intelligent dose reduction: multidisciplinary conference organized by the Society of Pediatric Radiology, August 18–19, 2001.Pediatr Radiol2002; 32:217-313. Crossref, Google Scholar3 European Commission. European guidelines on quality criteria for computed tomography: Report EUR 16262 EN Luxembourg: European Commission, 1999; 69-78. Google Scholar4 Tack D, De Maertelaer V, Gevenois PA. Dose reduction in multidetector CT using attenuation-based online tube current modulation. AJR Am J Roentgenol 2003; 181:331-334. Crossref, Medline, Google Scholar5 Sigal-Cinqualbre AB, Hennequin R, Abada HT, Chen X, Paul JF. Low-kilovoltage multi–detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 2004; 231:169-174. Link, Google ScholarArticle HistoryPublished in print: Oct 2004 FiguresReferencesRelatedDetailsCited ByAutomatic Exposure Control Techniques for Individual Dose AdaptationStefania M. R. Rizzo, , Mannudeep K. Kalra, , Bernhard Schmidt, , 1 April 2005 | Radiology, Vol. 235, No. 1Recommended Articles RSNA Education Exhibits RSNA Case Collection Vol. 233, No. 1 Metrics Altmetric Score PDF download

Similar Papers
  • Research Article
  • Citations4

Computed tomography portography of patients with cirrhosis with normal body mass index

  • Nov 01, 2018
  • Medicine
  • Sulan Liu +6
  • Research Article
  • Citations444

CT Dose Index and Patient Dose: They AreNotthe Same Thing

  • May 01, 2011
  • Radiology
  • Cynthia H Mccollough +5
  • Research Article
  • Citations10

Adaptive statistical iterative reconstruction use for radiation dose reduction in pediatric lower-extremity CT: impact on diagnostic image quality.

  • Dec 26, 2017
  • Skeletal Radiology
  • Amisha Shah +5
  • Research Article
  • Citations3

Gridless adult cervical spine radiography and its' effect on image quality and radiation dose: A phantom study

  • Dec 22, 2023
  • Radiography (London, England : 1995)
  • N Mekis +7
  • Research Article
  • Citations6

Radiation protection in CT-guided interventions: does real-time dose visualisation lead to a reduction in radiation dose to participating radiologists? A single-centre evaluation

  • Feb 15, 2024
  • Clinical radiology
  • A Koch +5
  • Research Article
  • Citations176

Influence of CBCT exposure conditions on radiation dose

  • Apr 18, 2008
  • Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology
  • J Martin Palomo +2
  • PDF
  • Research Article
  • Citations4

Radiation dose reduction without degrading image quality during computed tomography examinations: Dosimetry and quality control study

  • Jun 04, 2014
  • International Journal of Cancer Therapy and Oncology
  • George Felix Acquah +4
  • Research Article
  • Citations7

Evaluation of Dose Reduction and Image Quality in Pediatric Multi-Detector CT

  • Jul 15, 2010
  • Journal of the Korean Physical Society
  • Seung-Wan Lee +3
  • Research Article
  • Citations298

Radiation dose and image quality in pediatric CT: effect of technical factors and phantom size and shape.

  • Sep 09, 2004
  • Radiology
  • Marilyn J Siegel +4
  • PDF
  • Research Article
  • Citations4

Assessing and improving radiation safety in cardiac catheterization: a study from Cairo University Hospital

  • Feb 09, 2024
  • The Egyptian Heart Journal
  • Muhammad Ghallab +9
  • Research Article
  • Citations8

Reducing contrast media and radiation dose in CT angiography at low tube voltage: animal study with photon-counting detector CT

  • Mar 24, 2025
  • European Radiology Experimental
  • Konstantin Klambauer +8
  • Research Article
  • Citations29

Effect of a Standardized Quality-Improvement Protocol on Radiation Dose in Coronary Computed Tomographic Angiography

  • Oct 14, 2010
  • The American Journal of Cardiology
  • Troy M Labounty +7
  • Research Article
  • Citations5

Image optimization and reduction of radiation dose in CT of the paranasal sinuses

  • Jun 17, 2020
  • Biomedical physics & engineering express
  • Mohammad Davoudi +1
  • Research Article
  • Citations9

Reducing the radiation dose with the adaptive statistical iterative reconstruction technique for chest CT in adults: a parameter study

  • Apr 05, 2014
  • Chinese Medical Journal
  • Wenyun Liu +4
  • Research Article
  • Citations16

MO‐A‐ValB‐01: Tradeoffs in Image Quality and Radiation Dose for CT

  • Jun 01, 2006
  • Medical Physics
  • M Mcnitt‐Gray
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.