• Home
  • Search
  • Cone-beam pair-wise data consistency conditions in helical CT.
  • Open Access IconOpen Access
  • Cite Icon1
  • https://doi.org/10.1109/tmi.2023.3265812Copy DOI Icon

Cone-beam pair-wise data consistency conditions in helical CT.

Show More
  • Abstract
  • Highlights & Summary
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Data consistency conditions (DCC) are mathematical equations characterizing the redundancy in X-ray projections. They have been used to correct inconsistent projections before computed tomography (CT) reconstruction. This article investigates DCC for a helical acquisition with a cylindrical detector, the geometry of most diagnostic CT scanners. The acquired projections are analyzed pair-by-pair. The intersection of each plane containing the two source positions with the corresponding cone-beams defines two fan-beams for which a DCC can be computed. Instead of rebinning the two fan-beam projections to a conventional detector, we directly derive the DCC in detector coordinates. If the line defined by two source positions intersects the field-of-view (FOV), the DCC presents a singularity which is accounted for in our numerical implementation to increase the number of DCC compared to previous approaches which excluded these pairs of source positions. Axial truncation of the projections is addressed by identifying for which set of planes containing the two source positions the fan-beams are not truncated. The ability of these DCC to detect breathing motion has been evaluated on simulated and real projections. Our results indicate that the DCC can detect motion if the baseline and the FOV do not intersect. If they do, the inconsistency due to motion is dominated by discretization errors and noise. We therefore propose to normalize the inconsistency by the noise to obtain a noise-aware metric which is mostly sensitive to inconsistencies due to motion. Combined with a moving average to reduce noise, the derived DCC can detect breathing motion.

Similar Papers
  • Research Article

MO‐D‐330A‐02: Motion Artifact Correction Using a Novel Data Consistency Condition

  • Jun 01, 2006
  • Medical Physics
  • S Leng +2
  • Research Article
  • Citations23

Data consistency condition–based beam-hardening correction

  • Jul 01, 2011
  • Optical Engineering
  • Xuanqin Mou
  • Research Article
  • Citations11

"High-precision, reconstructed 3D model" of skull scanned by conebeam CT: Reproducibility verified using CAD/CAM data.

  • Nov 24, 2015
  • Legal medicine (Tokyo, Japan)
  • Seiko Katsumura +6
  • Research Article
  • Citations6

Unexpected significant findings non-related to prostate cancer identified using combined prostate-specific membrane antigen positron emission tomography/CT and diagnostic CT scan in primary staging for prostate cancer.

  • Mar 06, 2019
  • Journal of medical imaging and radiation oncology
  • Louise Mcewan +3
  • Research Article
  • Citations321

Pancreatic cancer: value of dual-phase helical CT in assessing resectability.

  • Feb 01, 1998
  • Radiology
  • S J Diehl +4
  • Research Article
  • Citations184

Crohn's disease evaluation: Comparison of contrast-enhanced MR imaging and single-phase helical CT scanning

  • Feb 01, 2000
  • Journal of Magnetic Resonance Imaging
  • Russell N Low +3
  • Conference Article
  • Citations26

<title>Three-dimensional approach to lung nodule detection in helical CT</title>

  • May 21, 1999
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Samuel G Armato Iii +4
  • Research Article
  • Citations27

Liver volume assessment by conventional vs. helical CT.

  • May 01, 1995
  • Abdominal imaging
  • J Stapakis +3
  • Research Article
  • Citations88

Imaging of neuroendocrine tumors: accuracy of helical CT versus SRS.

  • May 27, 2004
  • Abdominal Imaging
  • B Kumbasar +5
  • Research Article
  • Citations202

Renal lymphoma: CT patterns with emphasis on helical CT.

  • Jan 01, 2000
  • RadioGraphics
  • Bruce A Urban +1
  • Research Article
  • Citations265

Acute pulmonary embolism: role of helical CT in 164 patients with intermediate probability at ventilation-perfusion scintigraphy and normal results at duplex US of the legs.

  • Nov 01, 1997
  • Radiology
  • G R Ferretti +8
  • Research Article

Evaluation of the role of helical CT in blunt abdominal trauma

  • Dec 21, 2024
  • Panacea Journal of Medical Sciences
  • Fatima Ibrahim Shaikh +1
  • Research Article
  • Citations20

Impact of Helical Computed Tomography on the Outcomes of Emergency Department Patients with Suspected Appendicitis

  • Aug 01, 2003
  • Academic Emergency Medicine
  • Sam S Torbati +1
  • Research Article
  • Citations276

Ultrasonography, Computed Tomography and Magnetic Resonance Imaging for Diagnosis and Determining Resectability of Pancreatic Adenocarcinoma

  • Jul 01, 2005
  • Journal of Computer Assisted Tomography
  • Shandra Bipat +6
  • Research Article
  • Citations102

Ventilation-Perfusion Scanning and Helical CT in Suspected Pulmonary Embolism: Meta-Analysis of Diagnostic Performance

  • Mar 01, 2005
  • Radiology
  • Yasuaki Hayashino +3
Cactus Communications logo