  • MO‐D‐330A‐02: Motion Artifact Correction Using a Novel Data Consistency Condition
  • https://doi.org/10.1118/1.2241404Copy DOI Icon

MO‐D‐330A‐02: Motion Artifact Correction Using a Novel Data Consistency Condition

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Purpose: During diagnostic x‐ray CT imaging procedures or image guided radiotherapy, image quality will be degraded if target organs move during the data acquisition. This can be caused by patients' occasional motion or by intrinsic motion like cardiac and respiratory motion. The inconsistency in the projection data is the major reason for the image quality degradation. We present and validate a method to improve the consistency of the projections using a novel Fan‐beam Data Consistency Condition (FDCC) such that the image quality can be improved. Method and Materials: Computer‐simulated dynamic phantoms are generated and projection data are acquired from these dynamic phantoms. Using the FDCC, individual projection data from one view of fan‐beam projections can be estimated from filtering all the other projection data acquired from different view angles. Then those projections contaminated by motion are re‐estimated using the FDCC, resulting in a corrected sinogram. A standard Fan‐beam Filtered Back Projection (FBP) reconstruction algorithm is then used to reconstruct images from the corrected sinograms. Motion artifacts can be alleviated using this procedure. Results: Images are reconstructed from both the original sinogram where projections are contaminated by motion and the corrected sinogram after applying the FDCC. Strong motion artifacts are observed in the images reconstructed from the contaminated sinogram while improvement can be found in the reconstructed images using the corrected sinogram. Conclusions: A novel method using the new FDCC is proposed to combat the motion artifacts due to the temporal inconsistency in the projection data. Numerical simulations were conducted to demonstrate the potential of this correction scheme to mitigate motion artifacts. Thus, the preliminary numerical results indicate that the FDCC has potential use in combating both cardiac and respiratory motion in CT imaging.

Similar Papers
  • Research Article
  • Citations51

Cardiac motion correction based on partial angle reconstructed images in x‐ray CT

  • May 01, 2015
  • Medical Physics
  • Seungeon Kim +2
  • Research Article
  • Citations23

Consistency-based respiratory motion estimation in rotational angiography.

  • Sep 01, 2017
  • Medical Physics
  • Mathias Unberath +3
  • Research Article
  • Citations30

Software‐based respiratory gating for small animal conebeam CT

  • Apr 15, 2008
  • Medical Physics
  • T H Farncombe
  • Research Article
  • Citations9

Self-gated cardiac cine imaging using phase information.

  • Mar 22, 2016
  • Magnetic Resonance in Medicine
  • Hyunseok Seo +3
  • Research Article
  • Citations1

Cone-beam pair-wise data consistency conditions in helical CT.

  • Oct 01, 2023
  • IEEE Transactions on Medical Imaging
  • Mélanie Mouchet +3
  • PDF
  • Research Article
  • Citations27

Characterization of Respiratory and Cardiac Motion from Electro-Anatomical Mapping Data for Improved Fusion of MRI to Left Ventricular Electrograms

  • Nov 08, 2013
  • PLoS ONE
  • Sébastien Roujol +3
  • Abstract
  • Citations1

Image Guided, Motion-free Patient Body Setup using 3D Volumetric Image Registration of Classified Stable Bony Landmarks

  • Aug 20, 2008
  • International Journal of Radiation Oncology*Biology*Physics
  • G Li +9
  • Research Article

Image registration of a three-dimensional dynamic phantom in four-dimensional cone-beam computed tomography and four-dimensional computed tomography

  • Sep 15, 2015
  • Chinese Journal of Radiation Oncology
  • Chen Su +6
  • Research Article
  • Citations17

Impact of motion artefacts and motion-artefact correction on diagnostic accuracy of apical periodontitis in CBCT images: an ex vivo study in human cadavers.

  • Jun 11, 2020
  • International Endodontic Journal
  • R Spin‐Neto +4
  • Research Article
  • Citations40

Non-rigid dual respiratory and cardiac motion correction methods after, during, and before image reconstruction for 4D cardiac PET

  • Dec 01, 2015
  • Physics in Medicine & Biology
  • Tao Feng +3
  • Conference Article
  • Citations1

Suppression of motion-induced streak artifacts along chords in fan-beam BPF-reconstructions of motion-contaminated projection data

  • Mar 02, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Martin King +4
  • Research Article
  • Citations6

Cardiac motion and spillover correction for quantitative PET imaging using dynamic MRI.

  • Jan 15, 2019
  • Medical physics
  • Stephanie Marchesseau +7
  • Research Article
  • Citations2

Optimization dose and image quality enhancement of ct scan with back projection filters on the use of automatic exposure control

  • Jul 01, 2021
  • Journal of Physics: Conference Series
  • L Fitriana +2
  • Conference Article

CT image reconstruction on Pi-lines in Parallel-Beam

  • Nov 01, 2013
  • Yang Guiqin +3
  • Research Article
  • Citations15

A Survey of Radiation Doses in CT Urography Before and After Implementation of Iterative Reconstruction.

  • Sep 01, 2015
  • American Journal of Roentgenology
  • Aart J Van Der Molen +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.