• Home
  • Search
  • Correction: "Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model-based dose calculations" https://doi.org/10.1002/mp.16721.
  • https://doi.org/10.1002/mp.17286Copy DOI Icon

Correction: "Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model-based dose calculations" https://doi.org/10.1002/mp.16721.

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Supplementary Materials referenced in the text containing dosimetric comparisons for all test cases were not previously published alongside the paper and are attached here. Single seed in water phantom 13 seeds in water phantom, no plaque, no interseed attenuation (TG-43) 13 seeds in water phantom, no plaque, with interseed attenuation Full plaque in water phantom Full plaque in realistic eye phantom. Calculations for each test case were performed using three Monte Carlo (MC) codes: egs_brachy (based on EGSnrc), MCNP, and TOPAS (based on Geant4). Calculations for test cases 1, 4, and 5 are also performed using a research version of the OncentraBrachy ACE treatment planning system. The figures presented here are summarized in Table VII of the original paper. They demonstrate that overall local agreement ( % Δ D l o c a l $\% \Delta {D}_{local}$ ) between MC codes is approximately 2.5% and local agreement ( % Δ D l o c a l $\% \Delta {D}_{local}$ ) between ACE and MC is approximately 5% (test case 1) to 20% (test cases 4 and 5); global agreement ( % Δ D g l o b a l $\% \Delta {D}_{global}$ ) between MC codes is approximately 2% (4% for test case 5) and global agreement between ACE and MC is approximately 0.4% (test case 1) to 10% (test cases 4 and 5). Please note: The publisher is not responsible for the content or functionality of any supporting information supplied by the authors. Any queries (other than missing content) should be directed to the corresponding author for the article.

Similar Papers
  • Research Article
  • Citations7

Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model-based dose calculations.

  • Sep 04, 2023
  • Medical physics
  • Elizabeth M Fletcher +8
  • Research Article
  • Citations1

SU‐E‐T‐509: DICOM Test Case Plans for Model‐Based Dose Calculations Methods in Brachytherapy

  • Jun 01, 2013
  • Medical Physics
  • P Papagiannis +12
  • Research Article

Consistent Method for Calculating Directional Diffusion Coefficients Using Monte Carlo

  • Sep 22, 2025
  • Nuclear Science and Engineering
  • Vidor H Lujan +2
  • Research Article

Impact of implanted metal plates on radiation dose distribution in vivo by Monte Carlo code

  • Sep 15, 2011
  • Chinese Journal of Radiation Oncology
  • Xinye Ni +9
  • Research Article
  • Citations12

Direct MC conversion of absorbed dose to graphite to absorbed dose to water for 6060Co radiation

  • Nov 14, 2012
  • Radiation Protection Dosimetry
  • J E Lye +7
  • PDF
  • Research Article
  • Citations3

Comparison of the dosimetry of scandium-43 and scandium-44 patient organ doses in relation to commonly used gallium-68 for imaging neuroendocrine tumours

  • Jul 15, 2024
  • EJNMMI Physics
  • Carlos Vinícius Gomes +8
  • Research Article
  • Citations6

Pressurized Water Reactor Mixed Oxide/UO2 Transient Benchmark Calculations Using Monte Carlo Serpent 2 Code and Open Nodal Core Simulator ADPRES

  • Mar 16, 2021
  • Journal of Nuclear Engineering and Radiation Science
  • Muhammad Imron +1
  • Research Article
  • Citations11

Optimization treatment of point-wise nuclear data in Monte Carlo criticality and burnup calculations

  • Apr 20, 2011
  • Annals of Nuclear Energy
  • Yuxuan Liu +3
  • Research Article
  • Citations51

Validation of a GPU-based Monte Carlo code (gPMC) for proton radiation therapy: clinical cases study

  • Feb 26, 2015
  • Physics in Medicine & Biology
  • Drosoula Giantsoudi +5
  • Book Chapter
  • Citations1

The Modeling for Numerical Simulation of a Benchmark Model Based on CAD System

  • Jul 07, 2018
  • Minle Xu +1
  • Research Article
  • Citations2

Stochastic effects in H2SO4-H2O cluster growth

  • Apr 29, 2020
  • Aerosol Science and Technology
  • Christoph Köhn +2
  • Research Article
  • Citations1

WE‐C‐108‐05: A Hardware Accelerator Based Fast Monte Carlo Code for Radiation Dosimetry: Software Design and Preliminary Results

  • Jun 01, 2013
  • Medical Physics
  • X Du +4
  • Research Article

TH‐AB‐BRA‐05: Infrastructure and Process for Model‐Based Dose Calculation Software Commissioning in Brachytherapy

  • Jun 01, 2015
  • Medical Physics
  • R Sloboda +18
  • Research Article
  • Citations10

COMS eye plaque brachytherapy dosimetric sensitivity to source photon energy and seed design

  • May 07, 2013
  • Applied Radiation and Isotopes
  • Nolan L Gagne +1
  • Research Article

WE‐A‐BRB‐05: Methods to Optimize COMS Plaque Loading for Improved Dose Homogeneity and Conformity

  • Jun 01, 2012
  • Medical Physics
  • Nl Gagne +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.