• Home
  • Search
  • SU‐E‐T‐509: DICOM Test Case Plans for Model‐Based Dose Calculations Methods in Brachytherapy
  • Cite Icon1
  • https://doi.org/10.1118/1.4814938Copy DOI Icon

SU‐E‐T‐509: DICOM Test Case Plans for Model‐Based Dose Calculations Methods in Brachytherapy

Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Purpose: The TG‐186 report provides guidance to early adopters of model‐based dose calculation algorithms (MBDCAs) for brachytherapy. A charge of the AAPM‐ESTRO Working Group on MBDCA is to develop well‐defined test case plans, available as references for the software commissioning process to be performed by end‐users. The aim of this work is to develop test case plans for a generic HDR 192Ir source alone and in combination with a vaginal cylinder applicator with 180° tungsten‐alloy shielding in a DICOM‐based water phantom. Methods: A DICOM CT dataset was created with a 30 cm diameter water sphere surrounded by air. The voxel size was 1.33×1.33×1.33 mm3 for evaluating absorbed dose rate (cGy.h−1.U−1). Dose distributions were obtained in the planes x=0, y=0 and z=0. Three geometries were considered with the HDR source (a) at the center of sphere, (b) displaced 12.75 cm laterally, and (c) at the center of the applicator. Monte Carlo (MC) codes (Geant4, Penelope2009, MCNP5, and EGSnrc‐based BrachyDose) and Acuros were used. MC simulations were performed by multiple users to validate consistency of the DICOM reading, calculation set‐up, and dose reporting. Results: For all three geometries, MC results were generally within 2% agreement for r < 14 cm except at the sphere boundary where volume averaging occurred in voxels comprising two materials. There were no trends for r > 14 cm except that dosimetric agreement amongst the codes was limited by computational statistics. Results from Acuros and Penelope2009 were compared using a 2%/1.33 mm λ‐index criteria for r < 7 cm. Voxel pass rates were 100%, 100%, and 94% for geometries (a), (b), and (c), respectively. Conclusions: Dose rate distributions were consistent within statistical uncertainties among MC codes and for different users. Acuros reproduces MC data for the three geometries. These geometries may serve as test case plans for MBDCAs. T. Wareing is employee of Transpire Inc. that developed Acuros.

Similar Papers
  • Abstract

PO26 Presentation Time: 7:40 AM: Dosimetry Accuracy of a Model-Based Dose Calculation Algorithm in Modeling a Novel Direction Modulated Brachytherapy Tandem Applicator for the Cervical Cancer

  • Nov 01, 2022
  • Brachytherapy
  • Moeen Meftahi +1
  • Research Article
  • Citations7

Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model-based dose calculations.

  • Sep 04, 2023
  • Medical physics
  • Elizabeth M Fletcher +8
  • Addendum

Correction: "Generation and comparison of 3D dosimetric reference datasets for COMS eye plaque brachytherapy using model-based dose calculations" https://doi.org/10.1002/mp.16721.

  • Jul 03, 2024
  • Medical physics
  • Elizabeth M Fletcher +8
  • Research Article
  • Citations6

Cavity theory applications for kilovoltage cellular dosimetry

  • May 05, 2017
  • Physics in Medicine & Biology
  • P A K Oliver +1
  • Research Article
  • Citations29

On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning

  • Apr 28, 2017
  • Physics in Medicine & Biology
  • Eleftherios P Pappas +6
  • Research Article

Impact of implanted metal plates on radiation dose distribution in vivo by Monte Carlo code

  • Sep 15, 2011
  • Chinese Journal of Radiation Oncology
  • Xinye Ni +9
  • Research Article

TPSDose43: A new TG-43 based dose calculation code for brachytherapy

  • Aug 26, 2016
  • Physica Medica
  • G Yegin +1
  • Research Article
  • Citations25

Clinical transition to model-based dose calculation algorithm: A retrospective analysis of high-dose-rate tandem and ring brachytherapy of the cervix

  • Mar 29, 2017
  • Brachytherapy
  • Dayee Jacob +3
  • Research Article

Consistent Method for Calculating Directional Diffusion Coefficients Using Monte Carlo

  • Sep 22, 2025
  • Nuclear Science and Engineering
  • Vidor H Lujan +2
  • Research Article

TH‐AB‐BRA‐05: Infrastructure and Process for Model‐Based Dose Calculation Software Commissioning in Brachytherapy

  • Jun 01, 2015
  • Medical Physics
  • R Sloboda +18
  • Research Article

SU‐F‐T‐62: Three‐Dimensional Dosimetric Gamma Analysis for Impacts of Tissue Inhomogeneity Using Monte Carlo Simulation in Intracavitary Brachytheray for Cervix Carcinoma

  • Jun 01, 2016
  • Medical Physics
  • Tran Thi Thao Nguyen +5
  • PDF
  • Research Article
  • Citations3

Comparison of the dosimetry of scandium-43 and scandium-44 patient organ doses in relation to commonly used gallium-68 for imaging neuroendocrine tumours

  • Jul 15, 2024
  • EJNMMI Physics
  • Carlos Vinícius Gomes +8
  • Research Article
  • Citations6

Pressurized Water Reactor Mixed Oxide/UO2 Transient Benchmark Calculations Using Monte Carlo Serpent 2 Code and Open Nodal Core Simulator ADPRES

  • Mar 16, 2021
  • Journal of Nuclear Engineering and Radiation Science
  • Muhammad Imron +1
  • Research Article
  • Citations11

Optimization treatment of point-wise nuclear data in Monte Carlo criticality and burnup calculations

  • Apr 20, 2011
  • Annals of Nuclear Energy
  • Yuxuan Liu +3
  • Research Article
  • Citations12

Direct MC conversion of absorbed dose to graphite to absorbed dose to water for 6060Co radiation

  • Nov 14, 2012
  • Radiation Protection Dosimetry
  • J E Lye +7
Cactus Communications logo