• Home
  • Search
  • Design of a 4 π neutron detector for ß-delay neutron detection experiments.
  • https://doi.org/10.5821/dissertation-2117-95305Copy DOI Icon

Design of a 4 π neutron detector for ß-delay neutron detection experiments.

  • Feb 5, 2014
  • Vitaly Gorlychev
Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Beta delayed neutron emission probability is one of the main properties of neutron rich nuclei away from the valley of beta stability. The knowledge of this parameter provides the opportunity to extend the information on: the structure of atomic nuclei and its dependence with the N/Z ratio; the rapid neutron capture nucleosynthesis process (r-process), and hence study the formation of nuclei in supernova explosions; new data for reactor technology applications, since is one of the key features for the safe operation of actual nuclear power plants. The objective of the thesis was to design and test a prototype of a 4p neutron detector for DESPEC experiments related with the measurement of beta delayed neutron emission probabilities. As the neutron emission probabilities are low and the neutron energies are not well known, it is necessary to design a detector with high neutron detection efficiency, and a low dependence with neutron energy for a wide neutron energy ranges. The prototype designed has a mean neutron detection efficiency of the order of 27.1 % and is flat for neutron energies ranging from thermal values to 6 MeV. The detector designed is composed by 20 3He proportional counters at 20 atm, inserted in a polyethylene matrix. The counters are distributed in 2 concentric rings, surrounding a beam hole located at the central axis of the matrix This Master Thesis is divided in three main steps: 1) the analysis of different detector configurations and properties; 2) the selection of the definitive configuration of detector prototype, including the electronics and data acquisition system (DAQ); 3) the test of prototype and calibration with neutron sources. The detector configuration analysis has been done by means of Monte Carlo simulations with the code MCNPX. These MC simulations were useful to find: the optimal pressure of 3He counters; the best number of counters, taking in account the cost and the maximum neutron detection efficiency achievable; the number of counters in each concentric ring, and the distance of rings to the center of polyethylene matrix; the optimal counter length; or the shielding thickness for background radiation reduction. All of these studies were basic to obtain the optimal neutron detector configuration. The design of the detector also involved the selection of the most suitable electronics and Data Acquisition System (DAQ), as is described in this Thesis. This activity was done with the collaboration of the "Instituto de Física Corpuscular (IFIC- Valencia)". This PhD. Thesis includes the description of different tests done to check MC simulations of the neutron detector and the DAQ system. The definitive experiment done to check the detector design was done at IGISOL facility (Jyväskylä University, Finland). This experiment allowed to obtain the detector efficiency, measuring the beta-delayed neutron emission of two well known nuclei: 95Rb and 88Br. The results showed a good agreement between experiment and simulations.

Similar Papers
  • Research Article
  • Citations5

First Compilation and Evaluation of Beta-Delayed Neutron Emission Probabilities and Associated Half-Lives for A ≤ 72 Nuclei

  • Jun 01, 2014
  • Nuclear Data Sheets
  • M Birch +6
  • Research Article
  • Citations4

Towards radiation hard converter material for SiC-based fast neutron detectors

  • May 01, 2018
  • Journal of Instrumentation
  • S Tripathi +4
  • Research Article
  • Citations1

High-Precision Experiments with Trapped Radioactive Ions Produced at Relativistic Energies

  • Oct 08, 2024
  • Atoms
  • Timo Dickel +6
  • Research Article
  • Citations63

Hexagonal boron nitride neutron detectors with high detection efficiencies

  • Jan 23, 2018
  • Journal of Applied Physics
  • A Maity +4
  • Research Article
  • Citations43

Characteristics of 3D Micro-Structured Semiconductor High Efficiency Neutron Detectors

  • Jun 01, 2009
  • IEEE Transactions on Nuclear Science
  • S L Bellinger +3
  • Research Article
  • Citations1

Gamma-blindness & neutron detection efficiency assessments with centrifugally tensioned metastable fluid detectors in low-scatter environment

  • Oct 08, 2021
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • B Archambault +2
  • Conference Article
  • Citations5

Boron loaded plastic scintillator applied to active neutron measurements of waste drums

  • Oct 16, 2004
  • S Normand +3
  • Research Article
  • Citations19

A large 2D PSD for thermal neutron detection

  • Jun 01, 1997
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • R.B Knott +3
  • Research Article
  • Citations3

Ion assisted near-complete filling of high aspect ratio trenches for 3-D neutron detectors

  • Jan 07, 2021
  • Thin Solid Films
  • Gourav Kumar +5
  • Research Article
  • Citations2

Method for stabilizing the detection efficiency of grazing angle incidence boron-lined neutron detectors

  • May 01, 2024
  • Journal of Instrumentation
  • Lixing Liu +3
  • Research Article
  • Citations5

Performance optimization of scintillator neutron detectors for EMD in CSNS

  • May 25, 2023
  • Chinese Physics B
  • Xiaojie Cai +7
  • Conference Article
  • Citations1

Detection of neutrons using a novel three-dimensional optical random access memory technology (3D-ORAM)

  • Feb 14, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Brian M Cullum +5
  • Conference Article

Optimization Simulations of Micro-Layer Geometries with 10B/ZnO for Neutron Detection

  • Oct 31, 2020
  • Faruk Logoglu +1
  • Research Article
  • Citations9

10B Conformal Doping for Highly Efficient Thermal Neutron Detectors

  • Aug 10, 2020
  • ACS Sensors
  • Siddartha S Nandagopala Krishnan +4
  • Research Article

Measurement of Neutron-Production Double-Differential Cross Sections for Intermediate Energy Pion Incident Reaction

  • Jun 01, 2001
  • Journal of Nuclear Science and Technology
  • Yousuke Iwamoto +10
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.