Abstract

Chinese Spallation Neutron Source (CSNS) has successfully produced its first neutron beam in 28th August 2017. It has been running steadily from March, 2018. According to the construction plan, the engineering materials diffractometer (EMD) will be installed between 2019–2023. This instrument requires the neutron detectors with the cover area near 3 m2 in two 90° neutron diffraction angle positions, the neutron detecting efficiency is better than 40%@1 Å, and the spatial resolution is better than 4 mm×200 mm in horizontal and vertical directions respectively. We have developed a one-dimensional position-sensitive neutron detector based on the oblique 6LiF/ZnS(Ag) scintillators, wavelength shifting fibers, and SiPMs (silicon photomultipliers) readout. The inhomogeneity of the neutron detection efficiency between each pixel and each detector module, which caused by the inconsistency of the wave-length shifting fibers in collecting scintillation photons, needs to be mitigated before the installation. A performance optimization experiment of the detector modules was carried out on the BL20 (beam line 20) of CSNS. Using water sample, the neutron beam with Φ5 mm exit hole was dispersed related evenly into the forward space. According to the neutron counts of each pixel of the detector module, the readout electronics threshold of each pixel is adjusted. Compared with the unadjusted detector module, the inhomogeneity of the detection efficiency for the adjusted one has been improved from 69% to 90%. The test result of the diffraction peak of the standard sample Si showed that the adjusted detector module works well.

Similar Papers
  • Conference Article
  • Citations2

Three Dimensional Numerical Simulation of Thermal-Hydraulic Behaviors of CSNS Decoupled Poisoned Hydrogen Moderator With Non-Uniform Heat Source

  • Jun 26, 2016
  • Jian-Fei Tong +4
  • Research Article

Validation of source biasing method for its use in CSNS beamline shielding calculation

  • Dec 26, 2013
  • Radiation Protection Dosimetry
  • T.-R Liang +5
  • Research Article
  • Citations4

Towards radiation hard converter material for SiC-based fast neutron detectors

  • May 01, 2018
  • Journal of Instrumentation
  • S Tripathi +4
  • Research Article
  • Citations14

Study of a position-sensitive scintillator neutron detector

  • Nov 01, 2012
  • Chinese Physics C
  • Bin Tang +9
  • Research Article

Development of a choke-type movable tuner for CSNS DTL

  • Jul 01, 2025
  • Journal of Instrumentation
  • Peihua Qu +21
  • Research Article
  • Citations63

Hexagonal boron nitride neutron detectors with high detection efficiencies

  • Jan 23, 2018
  • Journal of Applied Physics
  • A Maity +4
  • Conference Article

Software design of electronics tests and data acquisition for a new gas detector

  • May 01, 2009
  • Dongxu Zhao +7
  • Research Article
  • Citations1

Gamma-blindness & neutron detection efficiency assessments with centrifugally tensioned metastable fluid detectors in low-scatter environment

  • Oct 08, 2021
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • B Archambault +2
  • Research Article
  • Citations2

Method for stabilizing the detection efficiency of grazing angle incidence boron-lined neutron detectors

  • May 01, 2024
  • Journal of Instrumentation
  • Lixing Liu +3
  • PDF
  • Research Article
  • Citations5

Field interference studies between bump magnets with different coil structures at Chinese Spallation Neutron Source

  • Mar 13, 2008
  • Physical Review Special Topics - Accelerators and Beams
  • Y Chen +1
  • Research Article
  • Citations7

Study of wave form compensation at CSNS/RCS magnets

  • Apr 30, 2018
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • S.Y Xu +7
  • Research Article
  • Citations43

Characteristics of 3D Micro-Structured Semiconductor High Efficiency Neutron Detectors

  • Jun 01, 2009
  • IEEE Transactions on Nuclear Science
  • S L Bellinger +3
  • Research Article
  • Citations11

Measurement and Simulation of the Neutron Response and Detection Efficiency of a Pb-Scintillating Fiber Calorimeter

  • Aug 06, 2007
  • IEEE Transactions on Nuclear Science
  • M Anelli +21
  • Research Article
  • Citations3

Spectrometer design of low energy neutrons for boron neutron capture therapy

  • Oct 01, 2021
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Masashi Takada +5
  • Dissertation

Design of a 4 π neutron detector for ß-delay neutron detection experiments.

  • Feb 05, 2014
  • Vitaly Gorlychev
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.