• Home
  • Search
  • Development of a collimator blurring compensation method using fine angular sampling projection data in SPECT
  • Cite Icon3
  • https://doi.org/10.1007/bf02984654Copy DOI Icon

Development of a collimator blurring compensation method using fine angular sampling projection data in SPECT

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Due to the collimator aperture, spatial resolution of SPECT data varies with source-to-detector distance. Since the radius of detector rotation is bigger when scanning larger patients, spatial resolution is degraded in these cases. Emitted gamma rays travel not only along the central axis of the collimator hole but also off-axis due to the collimator aperture. However, an off-axis ray at one angle would be a central-axis ray at another angle; therefore, raw projection data at one angle can be thought of as an ensemble of central-axis rays collected from a small arc equal to the collimator aperture. Thus, fine angular sampling can compensate for collimator blurring. By using a sampling pitch of less than half the collimator aperture angle, compensation was performed by subtracting the weighted sum of the projection data from the raw projection data. Collimator geometry and detector rotation radius determined the weighting function. Cylindrical phantom with four different-sized rods and torso phantom for Tl-201 cardiac SPECT simulation were used for evaluation. Aperture angle of the collimator was 7 degrees. Projection sampling pitch was 2 degrees. In both phantom studies, the proposed method showed improvement in contrast and reduction of partial volume effect, thereby indicating that the proposed method can compensate adequately for image blurring caused by the collimator aperture.

Similar Papers
  • Conference Article

Comparison between a new reconstruction algorithm (OPED) and filtered backprojection (FBP) for MDCT data

  • Feb 23, 2012
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Bernhard Renger +4
  • Research Article
  • Citations25

CT data storage reduction by means of compressing projection data instead of images: feasibility study.

  • Jun 01, 2001
  • Radiology
  • Kyongtae T Bae +1
  • Conference Article
  • Citations5

The direct calculation of parametric images from raw PET data using maximum likelihood iterative reconstruction

  • Oct 21, 1995
  • J Matthews +5
  • Research Article
  • Citations95

Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

  • Jul 06, 2012
  • Medical Physics
  • Tianye Niu +1
  • Research Article
  • Citations19

Preliminary study of correction of original metal artifacts due to I-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy

  • Feb 01, 2006
  • Radiation Medicine
  • Yutaka Takahashi +7
  • Research Article
  • Citations21

The Effect of Radiation Dose Reduction on Computer-Aided Detection (CAD) Performance in a Low-Dose Lung Cancer Screening Population

  • Mar 14, 2017
  • Medical physics
  • Stefano Young +11
  • Conference Article
  • Citations1

A real-time porosity mapping solution for synchrotron micro-CT of large 3D printed parts (Conference Presentation)

  • Oct 03, 2022
  • Aniket Tekawade +8
  • Research Article

SU‐FF‐I‐45: An Automatic Method for Reduction of Metal Artifacts Caused by Metallic Implants

  • Jun 01, 2009
  • Medical Physics
  • C Xu +3
  • Research Article
  • Citations23

Modeling of polychromatic attenuation using computed tomography reconstructed images.

  • Apr 01, 1999
  • Medical Physics
  • Chye Hwang Yan +4
  • Conference Article
  • Citations2

3D VSHARP®, a general-purpose CBCT scatter correction tool that uses the Linear Boltzmann Transport Equation

  • Feb 15, 2021
  • Josh Star-Lack +9
  • Book Chapter

Metal Artifact Reduction

  • Jan 01, 2016
  • Shrinivas D Desai +1
  • Research Article
  • Citations14

Techniques for virtual lung nodule insertion: volumetric and morphometric comparison of projection-based and image-based methods for quantitative CT

  • Aug 22, 2017
  • Physics in Medicine & Biology
  • Marthony Robins +7
  • Book Chapter
  • Citations4

Opportunities for health education: an analysis of nurse-client interactions in acute areas

  • Jan 01, 1993
  • Karen Jones
  • Research Article
  • Citations63

Virtual water accounting for building: case study for E-town, Beijing

  • Dec 28, 2013
  • Journal of Cleaner Production
  • Jing Meng +7
  • Conference Article

Synthesised Direct Kinetic Parametric Image Reconstruction

  • Nov 01, 2025
  • Laurence Vass +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.