Abstract

Previously the Orthogonal Polynomial Expansion on the Disk (OPED) algorithm was presented. Further, in prototype experiments in combination with the CT D`or geometry feasibility was demonstrated. In this study we implemented OPED with a clinical Scanner, and evaluated the potential using phantom studies. All studies were acquired on a Siemens Somatom 64 (Erlangen, Germany) scanner, where raw projection data were reconstructed with the conventional FBP reconstruction and the OPED algorithm. OPED allows one to use fan beam geometry directly without any additional procedures such as interpolation or rebinning if using the CT D`or geometry. In particular, OPED describes an approximation of the image function as a sum of polynomials using Chebychev polynomials. For performance evaluation, the Catphan phantom 600 was imaged. OPED Images where reconstructed using C++ and MATLAB® .We measured uniformity, MTF and CNR for different dose levels and compared these to standard FBP images reconstructions with different filter kernels. The integration and interpretation of the MDCT projection data for the OPED algorithm was accomplished. Reconstruction time is about 6 s on Quad-Core 3 GHz Intel Xeon processor. Typical artifacts are reduced when applying OPED. Using OPED the MTF maintains constant over the whole FOV. Uniformity and CNR are equal compared to FBP. Advantages of OPED were demonstrated by applying the algorithm to projections images from a clinical MDCT scanner. In the future, we see OPED applications for low-dose or limited angle geometries to reduce the radiation dose while improving diagnostic quality of the reconstructed slices.

Similar Papers
  • Research Article
  • Citations11

Comparison of Reconstruction Algorithms for Decreasing the Exposure Dose During Digital Tomosynthesis for Arthroplasty: a Phantom Study.

  • Mar 04, 2016
  • Journal of Digital Imaging
  • Tsutomu Gomi +5
  • Research Article
  • Citations57

Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR)

  • Oct 03, 2013
  • Medical Physics
  • Baiyu Chen +5
  • Research Article
  • Citations52

Preserving image texture while reducing radiation dose with a deep learning image reconstruction algorithm in chest CT: A phantom study.

  • Jan 01, 2021
  • Physica Medica
  • Caro Franck +3
  • Research Article
  • Citations4

Performance of high-resolution CT for detection and discrimination tasks related to stenotic lesions - A phantom study using model observers.

  • Jan 12, 2023
  • Medical physics
  • Andrew M Hernandez +4
  • Research Article
  • Citations13

A Task-dependent Investigation on Dose and Texture in CT Image Reconstruction.

  • Dec 04, 2019
  • IEEE transactions on radiation and plasma medical sciences
  • Yongfeng Gao +9
  • Research Article
  • Citations11

Volumetric measurement of artificial pure ground-glass nodules at low-dose CT: Comparisons between hybrid iterative reconstruction and filtered back projection

  • Sep 03, 2015
  • European Journal of Radiology
  • Noriyuki Sakai +9
  • Research Article
  • Citations2

WE‐A‐301‐10: How Much CT Radiation Dose Can Model Based Iterative Reconstruction (Veo) Save? — A Physical Evaluation of the Image Quality Using Standard Phantoms

  • Jun 01, 2011
  • Medical Physics
  • A Cohen +6
  • Research Article
  • Citations127

Six iterative reconstruction algorithms in brain CT: a phantom study on image quality at different radiation dose levels

  • Sep 18, 2013
  • The British Journal of Radiology
  • A Löve +5
  • Research Article
  • Citations20

Optimization of image quality and accuracy of low iodine concentration quantification as function of dose level and reconstruction algorithm for abdominal imaging using dual-source CT: A phantom study

  • Oct 06, 2021
  • Diagnostic and Interventional Imaging
  • Djamel Dabli +7
  • PDF
  • Research Article
  • Citations72

Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM

  • Aug 25, 2005
  • BMC Medical Imaging
  • Pasha Razifar +6
  • Research Article
  • Citations10

Image quality evaluation in deep-learning-based CT noise reduction using virtual imaging trial methods: Contrast-dependent spatial resolution.

  • Mar 31, 2024
  • Medical physics
  • Zhongxing Zhou +4
  • Research Article
  • Citations3

Development of a collimator blurring compensation method using fine angular sampling projection data in SPECT

  • May 01, 2006
  • Annals of Nuclear Medicine
  • Nobutoku Motomura +4
  • Research Article
  • Citations19

Preliminary study of correction of original metal artifacts due to I-125 seeds in postimplant dosimetry for prostate permanent implant brachytherapy

  • Feb 01, 2006
  • Radiation Medicine
  • Yutaka Takahashi +7
  • Research Article
  • Citations12

Localization of liver lesions in abdominal CT imaging: I. Correlation of human observer performance between anatomical and uniform backgrounds**Selected sections presented during oral presentation at 2017 RSNA Annual Meeting.

  • May 01, 2019
  • Physics in Medicine & Biology
  • Samantha K N Dilger +7
  • Research Article
  • Citations95

Accelerated barrier optimization compressed sensing (ABOCS) reconstruction for cone-beam CT: phantom studies.

  • Jul 06, 2012
  • Medical Physics
  • Tianye Niu +1
Cactus Communications logo