• Home
  • Search
  • Development of attenuation correction methods using deep learning in brain-perfusion single-photon emission computed tomography.
  • Cite Icon14
  • https://doi.org/10.1002/mp.15016Copy DOI Icon

Development of attenuation correction methods using deep learning in brain-perfusion single-photon emission computed tomography.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Computed tomography (CT)-based attenuation correction (CTAC) in single-photon emission computed tomography (SPECT) is highly accurate, but it requires hybrid SPECT/CT instruments and additional radiation exposure. To obtain attenuation correction (AC) without the need for additional CT images, a deep learning method was used to generate pseudo-CT images has previously been reported, but it is limited because of cross-modality transformation, resulting in misalignment and modality-specific artifacts. This study aimed to develop a deep learning-based approach using non-attenuation-corrected (NAC) images and CTAC-based images for training to yield AC images in brain-perfusion SPECT. This study also investigated whether the proposed approach is superior to conventional Chang's AC (ChangAC). In total, 236 patients who underwent brain-perfusion SPECT were randomly divided into two groups: the training group (189 patients; 80%) and the test group (47 patients; 20%). Two models were constructed using Autoencoder (AutoencoderAC) and U-Net (U-NetAC), respectively. ChangAC, AutoencoderAC, and U-NetAC approaches were compared with CTAC using qualitative analysis (visual evaluation) and quantitative analysis (normalized mean squared error [NMSE] and the percentage error in each brain region). Statistical analyses were performed using the Wilcoxon signed-rank sum test and Bland-Altman analysis. U-NetAC had the highest visual evaluation score. The NMSE results for the U-NetAC were the lowest, followed by AutoencoderAC and ChangAC (P<0.001). Bland-Altman analysis showed a fixed bias for ChangAC and AutoencoderAC and a proportional bias for ChangAC. ChangAC underestimated counts by 30-40% in all brain regions. AutoencoderAC and U-NetAC produced mean errors of <1% and maximum errors of 3%, respectively. New deep learning-based AC methods for AutoencoderAC and U-NetAC were developed. Their accuracy was higher than that obtained by ChangAC. U-NetAC exhibited higher qualitative and quantitative accuracy than AutoencoderAC. We generated highly accurate AC images directly from NAC images without the need for intermediate pseudo-CT images. To verify our models' generalizability, external validation is required.

Similar Papers
  • PDF
  • Research Article
  • Citations26

CT-based attenuation correction in I-123-ioflupane SPECT.

  • Sep 30, 2014
  • PLoS ONE
  • Catharina Lange +10
  • Research Article

The Comparison of Quantitative Evaluation Results of the MPS SPECT/CT and Coronary Angiography: Determining the Most Valuable Quantitative Evaluation Score

  • Oct 01, 2021
  • Molecular Imaging and Radionuclide Therapy
  • Nazlı Pınar Karahan Şen +3
  • Research Article
  • Citations8

18F-fluoride PET/CT for bone scanning

  • Jan 01, 2012
  • Nuklearmedizin
  • T Dannat +4
  • Conference Article
  • Citations5

A study of the effects of attenuation correction on tumor detection in SPECT oncology

  • Oct 16, 2004
  • Chuanyong Bai +1
  • Research Article
  • Citations25

Influence of attenuation correction by integrated low-dose CT on somatostatin receptor SPECT

  • Oct 01, 2007
  • Nuclear Medicine Communications
  • Juri Ruf +7
  • Research Article

Optimization of the Attenuation Coefficient for Chang Attenuation Correction in 123I Brain Perfusion SPECT.

  • Feb 07, 2023
  • Journal of nuclear medicine technology
  • Taisuke Murata +8
  • Research Article
  • Citations6

Comparison of the Diagnostic Performance of Myocardial Perfusion Scintigraphy with and Without Attenuation Correction

  • Jun 01, 2022
  • Molecular Imaging and Radionuclide Therapy
  • Sira Vachatimanont +2
  • Conference Article
  • Citations1

CT Based Attenuation Correction for PET Brain Imaging

  • Jan 01, 2006
  • Stephen J Lokitz +6
  • Research Article
  • Citations6

Robust, fully automatic delineation of the head contour by stereotactical normalization for attenuation correction according to Chang in dopamine transporter scintigraphy.

  • Feb 26, 2015
  • European Radiology
  • Catharina Lange +10
  • Research Article
  • Citations3

Does applying resolution recovery to normal databases confer an advantage over conventional 3D-stereotactic surface projection techniques?

  • Feb 04, 2017
  • Radiological physics and technology
  • Nobuhiro Yada +9
  • Research Article
  • Citations21

Ultra-low dose CT attenuation correction for PET/CT: analysis of sparse view data acquisition and reconstruction algorithms

  • Sep 09, 2015
  • Physics in Medicine & Biology
  • Xue Rui +7
  • Conference Article
  • Citations6

Attenuation Correction for Myocardial Perfusion SPECT Imaging in the Image Domain

  • Oct 16, 2021
  • Samaneh Mostafapour +7
  • PDF
  • Research Article
  • Citations57

NEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging

  • Aug 20, 2015
  • EJNMMI Physics
  • Susanne Ziegler +4
  • Research Article
  • Citations15

The Value of Attenuation Correction in Hybrid Cardiac SPECT/CT on Inferior Wall According to Body Mass Index

  • Jan 01, 2016
  • World Journal of Nuclear Medicine
  • Muge Tamam +3
  • Research Article

Impact of Attenuation Correction, Collimator, and Iterative Reconstruction Protocols on 67Ga SPECT/CT Quantification

  • Dec 26, 2023
  • Frontiers in Biomedical Technologies
  • Sahar Rezaei +5