• Home
  • Search
  • Attenuation Correction for Myocardial Perfusion SPECT Imaging in the Image Domain
  • Cite Icon6
  • https://doi.org/10.1109/nss/mic44867.2021.9875572Copy DOI Icon

Attenuation Correction for Myocardial Perfusion SPECT Imaging in the Image Domain

  • Oct 16, 2021
  • Samaneh Mostafapour +7 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Attenuation correction (AC), as an essential component of quantitative SPECT imaging, is highly challenging in the absence of CT or transmission scanning in dedicated cardiac SPECT devices. This study investigated the potential of direct attenuation correction (AC) of <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">99m</sup> Tc-sestamibi SPECT myocardial perfusion imaging (MPI) in the image domain using residual (ResNet) and UNet deep convolutional neural networks. MPI-SPECT <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">99m</sup> Tc-ses-tamibi images of 99 subjects were retrospectively used, considering non-attenuation corrected SPECT images as input and CT-based attenuation corrected (CT-AC) SPECT images as reference. Chang’s AC technique was also performed as a baseline for evaluating the performance of deep learning-based models. The quantitative accuracy of the attenuation corrected SPECT images was validated using the proposed methods considering the corresponding CT-AC SPECT images of 19 external datasets as reference. Image-derived metrics, including the voxel-wise mean absolute error (MAE), relative error (RE), structural similarity index measure (SSIM), as well as clinically relevant indices, such as total perfusion deficit (TPD), were calculated. The quantitative results obtained from the external validation dataset of the deep learning models exhibited good agreement with the reference CT-based attenuation corrected MPI-SPECT images. The deep learning models showed superior performance over Chang’s AC method. The ResNet and UNet models resulted in MAE of 20.24±17.63 and 13.65±11.23 and SSIM of 0.99±0.04 and 0.98±0.05, respectively. In comparison, Chang’s approach led to MAE and SSIM of 80.27±47.56 and 0.93±0.09, respectively. Similarly, the clinical evaluation showed a mean TPD of 12.78±9.22% and 12.57±8.93% for ResNet and UNet models, respectively, compared to TPD of 12.84±8.63% for reference SPECT CT-AC images. In contrast, Chang’s approach led to a mean TPD of 16.68±11.24%. The evaluation of deep learning approaches implemented in this work showed the promising potential of deep learning-based techniques in producing attenuation corrected MPI-SPECT images in the image domain without anatomical imaging.

Similar Papers
  • PDF
  • Research Article
  • Citations26

CT-based attenuation correction in I-123-ioflupane SPECT.

  • Sep 30, 2014
  • PLoS ONE
  • Catharina Lange +10
  • Research Article

Deep learning-guided attenuation and scatter correction of 99mTc-MAA SPECT images: towards quantitative analysis in 90Y-SIRT.

  • Jan 05, 2026
  • Annals of nuclear medicine
  • Zahra Mansouri +6
  • Conference Article

Preliminary Performance Evaluation of Deep Learning-based Attenuation Corrections for Myocardial Perfusion SPECT

  • Oct 16, 2021
  • Yu Du +2
  • Abstract
  • Citations1

LVEF measurements from cardiac PET/CT images obtained using CT based attenuation correction

  • Jul 01, 2004
  • Journal of Nuclear Cardiology
  • R.C Brunken +7
  • Research Article
  • Citations25

Influence of attenuation correction by integrated low-dose CT on somatostatin receptor SPECT

  • Oct 01, 2007
  • Nuclear Medicine Communications
  • Juri Ruf +7
  • Research Article
  • Citations88

Evaluation of an Atlas-Based PET Head Attenuation Correction Using PET/CT &amp; MR Patient Data

  • Oct 01, 2013
  • IEEE Transactions on Nuclear Science
  • S D Wollenweber +9
  • Research Article

`18´F−FDGを用いた脳PET検査の健常者データベースにおける透過撮像および減弱補正法の影響

  • Jan 01, 2010
  • Japanese Journal of Radiological Technology
  • Masato Kobayashi +9
  • Research Article

Is SPECT or CT Based Attenuation Correction More Quantitatively Accurate for Dedicated Breast SPECT Acquired with Non-Traditional Trajectories?

  • Oct 01, 2010
  • IEEE Nuclear Science Symposium conference record. Nuclear Science Symposium
  • K L Perez +4
  • PDF
  • Research Article
  • Citations3

Improved PET/MRI accuracy by use of static transmission source in empirically derived hardware attenuation correction

  • Mar 08, 2021
  • EJNMMI Physics
  • Adam Farag +4
  • Research Article
  • Citations20

Quantitative Evaluation of Atlas-based Attenuation Correction for Brain PET in an Integrated Time-of-Flight PET/MR Imaging System.

  • Feb 23, 2017
  • Radiology
  • Jaewon Yang +7
  • PDF
  • Research Article
  • Citations4

New SPM8-based MRAC method for simultaneous PET/MR brain images: comparison with state-of-the-art non-rigid registration methods

  • Jul 29, 2014
  • EJNMMI Physics
  • David Izquierdo-Garcia +8
  • Research Article
  • Citations14

Development of attenuation correction methods using deep learning in brain-perfusion single-photon emission computed tomography.

  • Jun 28, 2021
  • Medical Physics
  • Taisuke Murata +13
  • Research Article

A multi-source feature-driven deep learning method to generate linear energy transfer distribution for proton therapy.

  • Oct 01, 2025
  • Medical physics
  • Qian Liu +6
  • Research Article

Attenuation correction of cardiac 82Rb pet using deep learning generated synthetic CT.

  • Feb 26, 2026
  • EJNMMI physics
  • Kasper Jørgensen +4
  • PDF
  • Research Article
  • Citations57

NEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging

  • Aug 20, 2015
  • EJNMMI Physics
  • Susanne Ziegler +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.