Abstract

Although post-injection transmission scan (POST-TS) after 2-[(18)F]fluoro-2-deoxy- D-glucose ((18)F-FDG) injection[A1] is useful for short examination times, the emission count of (18)F-FDG[A2] in the regional brain area was not completely subtracted with use of the POST-TS method. The purpose of this study was to investigate the effect of POST-TS and attenuation correction (AC) methods on the normal database (NDB). A 10 min pre-injection transmission scan (PRE-TS) was performed before (18)F-FDG[A3] was injected in eighteen normal volunteers. A 10 min POST-TS was then conducted beginning 40 min after (18)F-FDG[A4] injection, followed by a 10 min 2-dimentional emission scanning. To reconstruct each image of normal volunteers, the reconstruction was performed using the filtered back-projection (FBP) method and the ordered subsets expectation maximization (OSEM) method, with transmission-based measured attenuation correction (MAC) and the segmented attenuation correction (SAC) technique. Subtraction images of NDB with PRE-TS or POST-TS were evaluated using 3D-SSP. A phantom study was also performed in addition to a human study, and assessment was by region of interests and profile curves. NDB images with POST-TS were significantly lower in the bilateral frontal lobes and higher in the parietal lobes and occipital lobes, including the precuneus, than those with PRE-TS, regardless of the different AC and reconstruction algorithms. Therefore, we have to be careful to confirm not only emission scan methods and reconstruction algorithms, but also TS methods and AC methods in the NDB. It will be best to perform PET examinations using the same TS methods and AC methods between NDB and patients.

Similar Papers
  • Research Article
  • Citations79

Influence of OSEM and segmented attenuation correction in the calculation of standardised uptake values for [18F]FDG PET

  • Jun 27, 2001
  • European Journal of Nuclear Medicine
  • D Visvikis +5
  • Research Article
  • Citations1

MR画像を使用した脳血流SPECT減弱補正法の検討

  • Jan 01, 2010
  • Japanese Journal of Radiological Technology
  • Takashi Mizuno +2
  • Research Article
  • Citations13

Effects of attenuation correction and reconstruction method on PET activation studies

  • Sep 17, 2003
  • NeuroImage
  • Catalina T Mesina +6
  • Research Article
  • Citations49

Characterization of ordered-subsets expectation maximization with 3d post-reconstruction gauss filtering and comparison with filtered backprojection in99mTc SPECT

  • Apr 01, 2005
  • Annals of Nuclear Medicine
  • Marco Brambilla +5
  • Research Article

Impact of Attenuation Correction on Quantification Accuracy in Preclinical Whole-Body PET Images

  • Apr 24, 2020
  • Frontiers in Physics
  • Thomas Wanek +6
  • Conference Article

Simultaneous post-injection transmission and emission contamination scans in a volume imaging PET scanner

  • Oct 21, 1995
  • R.J Smith +1
  • Research Article
  • Citations24

Attenuation correction of PET activation studies in the presenceof task-related motion

  • Aug 01, 2003
  • NeuroImage
  • Odile A Van Den Heuvel +4
  • Research Article
  • Citations9

Application of Chang's attenuation correction technique for single-photon emission computed tomography partial angle acquisition of Jaszczak phantom.

  • Jan 01, 2016
  • Journal of Medical Physics
  • Krishnendu Saha +2
  • Conference Article
  • Citations6

Attenuation Correction for Myocardial Perfusion SPECT Imaging in the Image Domain

  • Oct 16, 2021
  • Samaneh Mostafapour +7
  • Research Article

Reducing Artifacts in Pelvic Bone SPECT: An Assessment of Lesion Detectability Using Numerical and Human Observers

  • Oct 01, 2006
  • IEEE Transactions on Nuclear Science
  • T.H Farncombe +2
  • Research Article
  • Citations39

Performance measurement of PSF modeling reconstruction (True X) on Siemens Biograph TruePoint TrueV PET/CT

  • Feb 07, 2014
  • Annals of Nuclear Medicine
  • Young Sub Lee +5
  • PDF
  • Research Article
  • Citations72

Noise correlation in PET, CT, SPECT and PET/CT data evaluated using autocorrelation function: a phantom study on data, reconstructed using FBP and OSEM

  • Aug 25, 2005
  • BMC Medical Imaging
  • Pasha Razifar +6
  • Conference Article

Effects of collimator dependency and correction methods on I-123 SPECT images using x-ray-based attenuation map

  • Mar 02, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yu-Wen Yang +4
  • Research Article
  • Citations33

Comparison between MRI-based attenuation correction methods for brain PET in dementia patients.

  • Apr 20, 2016
  • European Journal of Nuclear Medicine and Molecular Imaging
  • Jorge Cabello +8
  • Research Article
  • Citations38

Evaluation of an attenuation correction method for thallium-201 myocardial perfusion tomographic imaging of patients with low likelihood of coronary artery disease

  • Jul 01, 1998
  • Journal of Nuclear Cardiology
  • Pierre Chouraqui +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.