• Home
  • Search
  • Difference in performance between 3D and 4D CBCT for lung imaging: a dose and image quality analysis
  • Cite Icon39
  • https://doi.org/10.1120/jacmp.v17i6.6459Copy DOI Icon

Difference in performance between 3D and 4D CBCT for lung imaging: a dose and image quality analysis

Show More
  • Abstract
  • Highlights & Summary
  • PDF
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The study was to describe and to compare the performance of 3D and 4D CBCT imaging modalities by measuring and analyzing the delivered dose and the image quality. The 3D (Chest) and 4D (Symmetry) CBCT Elekta XVI lung IGRT protocols were analyzed. Dose profiles were measured with TLDs inside a dedicated phantom. The dosimetric indicator cone‐beam dose index (CBDI) was evaluated. The image quality analysis was performed by assessing the contrast transfer function (CTF), the noise power spectrum (NPS) and the noise‐equivalent quanta (NEQ). Artifacts were also evaluated by simulating irregular breathing variations. The two imaging modalities showed different dose distributions within the phantom. At the center, the 3D CBCT delivered twice the dose of the 4D CBCT. The CTF was strongly reduced by motion compared to static conditions, resulting in a CTF reduction of 85% for the 3D CBCT and 65% for the 4D CBCT. The amplitude of the NPS was two times higher for the 4D CBCT than for the 3D CBCT. In the presence of motion, the NEQ of the 4D CBCT was 50% higher than the 3D CBCT. In the presence of breathing irregularities, the 4D CBCT protocol was mainly affected by view‐aliasing artifacts, which were typically cone‐beam artifacts, while the 3D CBCT protocol was mainly affected by duplication artifacts. The results showed that the 4D CBCT ensures a reasonable dose and better image quality when moving targets are involved compared to 3D CBCT. Therefore, 4D CBCT is a reliable imaging modality for lung free‐breathing radiation therapy.PACS number(s): 87.57.C‐, 87.57.uq, 87.53.Ly

Loading PDF

Similar Papers
  • Research Article
  • Citations2

PNMC: Four-dimensional conebeam CT reconstruction combining prior network and motion compensation

  • Feb 19, 2024
  • Computers in biology and medicine
  • Zhengwei Ou +9
  • Conference Article

Retracted: An Improved Convolutional Neural Network for the Image Enhancement

  • Mar 07, 2023
  • Muhammad Fiaz +2
  • PDF
  • Research Article
  • Citations12

Evaluation of interfractional variation of the centroid position and volume of internal target volume during stereotactic body radiotherapy of lung cancer using cone-beam computed tomography.

  • Mar 01, 2016
  • Journal of Applied Clinical Medical Physics
  • Yanan Sun +6
  • PDF
  • Research Article
  • Citations5

DeAPIR: Efficient and Enhanced Dental Arch-Guided Panoramic Image Reconstruction from CBCT Data

  • Nov 15, 2023
  • Applied Sciences
  • Fawad +1
  • Book Chapter
  • Citations10

2.02 - Physical Parameters of Image Quality

  • Jan 01, 2014
  • Comprehensive Biomedical Physics
  • A Konstantinidis
  • Conference Article
  • Citations2

<title>Assessment of objective image quality in digital radiography: noninvasive determination of the detective quantum efficiency</title>

  • Apr 11, 1996
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Karl-Friedrich Kamm +2
  • Research Article
  • Citations1

TU‐F‐CAMPUS‐I‐03: Enhancement of 4D CBCT Image Quality Using An Adaptive Prior Image Constrained Compressed Sensing

  • Jun 01, 2015
  • Medical Physics
  • H Lee +6
  • Research Article
  • Citations17

Improving lesion conspicuity in abdominal dual-energy CT with deep learning image reconstruction: a prospective study with five readers.

  • Mar 28, 2023
  • European Radiology
  • Jingyu Zhong +13
  • PDF
  • Research Article
  • Citations19

One-year analysis of Elekta CBCT image quality using NPS and MTF.

  • May 01, 2016
  • Journal of Applied Clinical Medical Physics
  • Satomi Nakahara +2
  • Research Article
  • Citations1

MO-FG-CAMPUS-JeP3-05: Evaluation of 4D CT-On-Rails Target Localization Methods for Free Breathing Liver Stereotactic Body Radiotherapy (SBRT)

  • Jun 01, 2016
  • Medical Physics
  • J Fan +11
  • Research Article
  • Citations2

Theoretical Framework for the Dual-Energy Cone-Beam CT Noise-Power Spectrum, NEQ, and Tasked-Based Detectability Index.

  • Feb 23, 2012
  • Proceedings of SPIE--the International Society for Optical Engineering
  • G J Gang +4
  • Research Article

SU-GG-I-10: Estimation of Organ Doses from KV-CBCT Imaging Systems Used in Radiation Therapy

  • Jun 01, 2010
  • Medical Physics
  • D Hyer +1
  • Research Article

Comparison of direct linear measurements on dental plaster cast and digital measurements obtained from laser scanner and Cone-Beam CT dental models

  • Oct 06, 2017
  • Italian Journal of Anatomy and Embryology
  • Luca Pisoni +6
  • Research Article
  • Citations1

Photon counting CT versus multi-slice CT for radiographic evaluation of postoperative cochlear implantation: Electrode characteristics and image-quality analysis.

  • Oct 01, 2025
  • European journal of radiology
  • Xu Tian +6
  • Research Article

Smart scanning for two: [18F]FDG dose optimization for pregnant patients using LAFOV PET/CT technology.

  • Mar 17, 2026
  • EJNMMI physics
  • Ilja S Deurloo +15
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.