• Home
  • Search
  • Dynamic cell tracking using time-lapse MRI with variable temporal resolution Cartesian sampling.
  • Cite Icon3
  • https://doi.org/10.1002/mrm.29796Copy DOI Icon

Dynamic cell tracking using time-lapse MRI with variable temporal resolution Cartesian sampling.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Temporal resolution of time-lapse MRI to track individual iron-labeled cells is limited by the required data-acquisition time to fill k-space and to reach sufficient SNR. Although motion of slowly patrolling monocytes can be resolved, detection of fast-moving immune cells requires improved acquisition and reconstruction strategies. For accelerated MRI cell tracking, a Cartesian sampling scheme was designed, in which the fully sampled and undersampled k-space data for different acceleration factors were acquired simultaneously, and multiple undersampling ratios could be chosen retrospectively. Compressed-sensing reconstruction was applied using dictionary learning and low-rank constraints. Detection of iron-labeled monocytes was evaluated with simulations, rotating phantom experiments and in vivo mouse brain measurements at 9.4 T. Fully sampled and 2.4-times and 4.8-times accelerated images were reconstructed and had sufficient contrast-to-noise ratio (CNR) for single cells to be resolved and followed dynamically. The phantom experiments showed an improvement in CNR of 6.1% per μm/s in the 4.8-times undersampled images. Geometric distortion of cells caused by motion was visibly reduced in the accelerated images, which enabled detection of moving cells with velocities of up to 7.0 μm/s. In vivo, additional cells were resolved in the accelerated images due to the improved temporal resolution. The easy-to-implement flexible Cartesian sampling scheme with compressed-sensing reconstruction permits simultaneous acquisition of both fully sampled and high temporal resolution images. The CNR of moving cells is effectively improved, enabling the recovery of high velocity cells with sufficient contrast at virtually no cost.

Similar Papers
  • Research Article
  • Citations75

Cardiac CINE MR imaging with a 32‐channel cardiac coil and parallel imaging: Impact of acceleration factors on image quality and volumetric accuracy

  • Dec 22, 2005
  • Journal of Magnetic Resonance Imaging
  • Bernd J Wintersperger +8
  • PDF
  • Research Article
  • Citations11

Research on the Lake Surface Water Temperature Downscaling Based on Deep Learning

  • Jan 01, 2021
  • IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
  • Zhenyu Yu +4
  • Research Article
  • Citations124

Susceptibility weighted imaging with multiple echoes

  • Dec 20, 2009
  • Journal of Magnetic Resonance Imaging
  • Christian Denk +1
  • Research Article
  • Citations34

Evaluation of gadobutrol, a macrocyclic, nonionic gadolinium chelate in a brain glioma model: Comparison with gadoterate meglumine and gadopentetate dimeglumine at 1.5 T, combined with an assessment of field strength dependence, specifically 1.5 versus 3 T

  • Feb 25, 2010
  • Journal of Magnetic Resonance Imaging
  • Ulrike I Attenberger +5
  • Research Article
  • Citations1

Quantitative analysis of deep learning reconstruction in CT angiography: Enhancing CNR and reducing dose.

  • Dec 18, 2024
  • Journal of X-ray science and technology
  • Chang-Lae Lee
  • Research Article
  • Citations131

Maximizing Iodine Contrast-to-Noise Ratios in Abdominal CT Imaging through Use of Energy Domain Noise Reduction and Virtual Monoenergetic Dual-Energy CT1

  • Apr 10, 2015
  • Radiology
  • Shuai Leng +3
  • PDF
  • Research Article
  • Citations1

A Spatial Compounding Method for Non-Delayed Sequential Beamforming

  • Oct 02, 2021
  • Applied Sciences
  • Siyi Liang +1
  • Research Article

A modular deep learning pipeline for enhanced plane-wave beamforming and B-mode image quality.

  • Jul 23, 2025
  • Medical physics
  • Hamza Hadri +2
  • Research Article
  • Citations23

Comparison of breast specific gamma imaging and molecular breast tomosynthesis in breast cancer detection: Evaluation in phantoms.

  • Jun 19, 2015
  • Medical physics
  • Zongyi Gong +1
  • Research Article
  • Citations1

An Investigation of PET Scan Parameters for Lesion Detection With GE VISTA Small-Animal Scanner Using Monte Carlo Simulation and Multivariate Analysis

  • Apr 01, 2013
  • IEEE Transactions on Nuclear Science
  • Tung-Hsin Wu +2
  • Research Article
  • Citations19

Increasing the darkfield contrast-to-noise ratio using a deconvolution-based information retrieval algorithm in X-ray grating-based phase-contrast imaging

  • Jul 19, 2013
  • Optics Express
  • Thomas Weber +9
  • Research Article
  • Citations6

CArtesian sampling with Variable density and Adjustable temporal resolution (CAVA).

  • Nov 12, 2019
  • Magnetic Resonance in Medicine
  • Adam Rich +6
  • Research Article
  • Citations7

Optimization of Correlation Kernel Size for Accurate Estimation of Myocardial Contraction and Relaxation

  • Jul 01, 2012
  • Japanese Journal of Applied Physics
  • Yasunori Honjo +2
  • Research Article
  • Citations10

Assessing the deep learning based image quality enhancements for the BGO based GE omni legend PET/CT

  • Oct 16, 2024
  • EJNMMI Physics
  • Meysam Dadgar +4
  • Research Article
  • Citations2

Adaptive dual-energy algorithm based on pre-calibrated weighting factors for chest radiography

  • Apr 21, 2022
  • Physics in Medicine & Biology
  • Ivan Romadanov +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.