- Research Article
22
- 10.1006/jmre.1998.1510
Evolution Strategy Optimization for Selective Pulses in NMR
- Oct 01, 1998
- Journal of Magnetic Resonance
- E Lunati + 4 more +4
Evolution Strategy Optimization for Selective Pulses in NMR
A rapid-profiling NMR pulse sequence has been designed to provide an interactive, real-time cardiac probe analogous to M-mode ultrasound. The pulse sequence employs a two-dimensional (2D) selective NMR pulse to excite a narrow (nominally 1-cm-diameter) cylinder of magnetization intersecting the heart. This procedure is followed by a readout gradient applied along the length of the cylinder, or "beam," to yield an M-mode type profile with a one-dimensional Fourier transform reconstruction. k-space techniques were used to design 2D pulses which excite cylinders characterized by either Gaussian or square radial excitation profiles. Images of phantoms acquired at 1.5 T confirm the predictions of the k-space analysis. The cylinder can be displaced interactively by modulating the rf excitation and the beam axis can be reoriented to any oblique direction by changing the relative mixing of the gradient waveforms. Flow compensation using bipolar gradient waveforms inverts the contrast of flowing blood and suppresses flow artifacts. A gated cardiac image is acquired as a reference to locate the excitation axis. A series of cardiac experiments was performed on several healthy volunteers. As the beam is moved and rotated to probe the myocardium, the profile plots resemble an M-mode echocardiogram. Unlike in M-mode echocardiography, however, the axis of interrogation is not limited to specific windows, and there is distinct flexibility of contrast. However, the temporal resolution is currently less than that achieved by ultrasound. NMR M-mode profiling provides a direct, fast method of measuring heart motion to assess cardiac function as part of an MR cardiac exam.
Evolution Strategy Optimization for Selective Pulses in NMR
Evolution Strategy Optimization for Selective Pulses in NMR
Selective J‐resolved‐HMQC‐1 and ‐2, new methods for measuring proton–proton coupling constants in strongly coupled spin systems
Efficient pulse sequences for measuring (1)H-(1)H coupling constants (JHH) in strongly coupled spin systems, named selective J-resolved-HMQC-1 and -2, have been developed. In the strongly coupled spin systems such as -CH2-CHA(OH)-CHB(OH)-CH2-, measurements of (3)JHAHB are generally difficult owing to the complicated splitting caused by the adjacent CH2 protons. For easier and accurate measurements of (3)JHAHB in such a spin system, a selective excitation pulse is incorporated into the J-resolved HMQC pulse sequence. In the proposed methods, only two strongly coupled protons, HA and HB which are excited by a selective pulse, are observed as J-resolved HMQC signals. The cross peaks of HA and HB appear as doublets owing to (3)JHAHB along the F1 dimension in the selective J-resolved HMQC-1 and -2 experiments. The efficiency of the proposed pulse sequences has been demonstrated in application to the stereochemical studies of the complicated natural product, monazomycin.
Read moreTwo-dimensional NMR spectroscopy with soft pulses
Two-dimensional NMR spectroscopy with soft pulses
NMR spectroscopy explained: simplified theory, applications and examples for organic chemistry and structural biology
NMR spectroscopy explained: simplified theory, applications and examples for organic chemistry and structural biology
Determination of moisture content of insulating oil by NMR method with selective pulses
The principal possibility of the use of NMR spectroscopy to determine the moisture content of insulating oils was demonstrated for the first time. The advantages of NMR pulse sequences with selective pulses are high accuracy and sensitivity that makes this method promising for practical applications.
Read moreVolume-selective NMR spectroscopy with self-refocusing pulses
Volume-selective NMR spectroscopy with self-refocusing pulses
Selective COSY‐J‐resolved‐HMBC, a new method for improving sensitivity of cross peaks of methine proton signals attached to a methyl group
Improved pulse sequences for measuring long-range C-H coupling constants ((n)J(C-H)), named selective COSY-J-resolved HMBC-1 and -2, have been developed. In the spin systems, such as -CH(C)-CH(A)(CH(3))-CH(B)-, a methine proton H(A) splits into a multiplet owing to several vicinal couplings with protons, resulting in attenuation of its cross-peak intensity. Therefore, the measurements of (n)J(C-H) with H(A) are generally difficult in the J-resolved HMBC or selective J-resolved HMBC spectrum. With the aim of accurate measurements of (n)J(C-H) in such a spin system, we have developed new pulse sequences, which transfer the magnetization of a methyl group to its adjacent methine proton. The proposed pulse sequences successfully enable to enhance the sensitivity of H(A) cross peak in comparison with the selective J-resolved HMBC pulse sequence.
Read moreIsotropic solid-state MQMAS NMR spectra for large quadrupolar interactions using satellite-transition selective inversion pulses and low rf fields
Isotropic solid-state MQMAS NMR spectra for large quadrupolar interactions using satellite-transition selective inversion pulses and low rf fields
Read more5105152 Magnetic resonance imaging and spectroscopy using a linear class of large tip-angle selective excitation pulses
5105152 Magnetic resonance imaging and spectroscopy using a linear class of large tip-angle selective excitation pulses
Selective saturation and inversion of multiple resonances in high-resolution solid-state 13C experiments using slow spinning CP/MAS and tailored DANTE pulse sequences
Selective saturation and inversion of multiple resonances in high-resolution solid-state 13C experiments using slow spinning CP/MAS and tailored DANTE pulse sequences
Read moreFully automated macromolecule suppressed single voxel glutamate spectroscopy (FAMOUS SVGS)
PurposeThe aim of the study was to develop and validate a new localized 1H MRS pulse sequence and automated post-processing software for the quantification of brain Glutamate (Glu) in clinical conditions at 7.0T in order to get reliable and reproducible results for acute intervention studies.MethodsHere we describe a new localized proton MRS method “Fully Automated MacrOmolecUle Suppressed Single Voxel Glutamate Spectroscopy (FAMOUS SVGS)” for measuring Glu. FAMOUS SVGS method consists of a new pulse sequence with optimized switchable water, metabolites and outer volume suppression modules, as well as a frequency selective inversion pulse and automated post-processing of the five spectra obtained. FAMOUS SVGS method was first validated with glutamate phantoms and then validated with test–retest repeatability studies in the occipital cortex of five normal volunteers at 7.0T.ResultsGlutamate concentrations estimated from phantoms with FAMOUS SVGS method correlated well with actual concentrations. Test–retest repeatability studies in human brain in vivo yielded less than 0.3 mM intra-subject variations in Glu concentrations.ConclusionsFAMOUS SVGS method enables Glu quantification in vivo at 7.0T with test–retest variability of less than 0.3 mM. We expect that we can reliably measure ≥0.5 mM change in glutamate due to any acute intervention.
Read moreGradient-enhanced TOCSY experiments with improved sensitivity and solvent suppression
Gradient-enhanced versions of the homonuclear TOCSY experiment are described, with solvent suppression and sensitivity superior to that of a conventional TOCSY experiment. The pulse sequences are constructed by appending a WATERGATE module to a z-filtered TOCSY experiment. Pulsed-field gradients and appropriately phased selective rf pulses are used to maintain precise control of the water magnetization vector. Problems associated with radiation damping and spin-locking of the water magnetization are thus alleviated. The water magnetization is returned to equilibrium prior to each acquisition, which improves water suppression and minimizes signal losses due to saturation transfer.
Read moreLactate detection in inducible and orthotopic Her2/neu mammary gland tumours in mouse models
This study compared the steady state concentration of lactate in an inducible Her2/nue transgenic breast cancer mouse model and in tumours from the same Her2/neu model grown orthotopically. In vivo lactate was detected by MRS using the Hadamard encoded selective multiple quantum coherence pulse sequence (HadSelMQC) recently developed by our laboratory. A lower lactate signal was observed in the inducible tumours compared to orthotopic tumours in vivo, while ex vivo analysis of perchloric acid extracts revealed similar amounts of this metabolite in both models. Histological staining of mammary tumour specimens showed a much higher level of fat tissue in inducible tumours compared to the orthotopic model. Phantom studies with [3-(13) C] lactate indicated that a lipid environment could significantly reduce the T2 of lactate and impede its detection. The transgenic inducible model for breast cancer not only better recapitulated the biological aspects of the human disease but also provided additional characteristics related to in vivo detection of lactate that are not available in orthotopic or xenograft models. This study suggests that the level of lactate measured by the HadSelMQC pulse sequence may be underestimated in human patients in the presence of high lipid levels that are typically encountered in the breast.
Read moreNew spatial localization method using pulsed high‐order field gradients (SHOT: Selection with high‐order gradient)
A new spatial localization method using an additional set of high-order magnetic field gradients is described. The method uses a nonlinear part of high-order magnetic field gradient patterns which allows us to select a volume in conjunction with the selective radiofrequency (RF) pulse. Unlike the other existing volume selection methods such as ISIS or SPARS, the proposed selection method requires only one RF-gradient pulse pair to select a volume in two directions. The center of the selected volume can be moved to any arbitrary location within the body by the addition of precalculated lower order gradients which are simultaneously pulsed with the high-order gradient. The method also has the potential for localized spectroscopy from the FID signal which can be realized by using oscillating second- and first-order gradients for 3D selection with a single RF pulse. By using the proposed localization method, it is possible to design more flexible pulse sequences, e.g., the shorter echo-time spectroscopic pulse sequence. We have designed and constructed a six-loop r2 (or x2 + y2) gradient coil for initial application. By simultaneously applying this second-order gradient and proper x, y, and/or z gradients, 2D selections were achieved in arbitrarily selected positions in conjunction with a single selective RF pulse. Phantom and animal experiments have been performed and the results appear promising, especially in areas of NMR spectroscopic imaging applications where spatial localization is essential.
Read more3D Brachial Plexus Neurography With Variable-Rate Selective Excitation RF Pulses.
Slab-selective radiofrequency (RF) pulses are commonly required in three-dimensional (3D) turbo spin echo (TSE) in brachial plexus magnetic resonance neurography (MRN). However, their long selective RF pulses lead to violation of Carr-Purcell-Meiboom-Gill conditions, which might increase imaging artifacts. That VERSE STIR-TSE would yield comparable motion artifact to conventional STIR-TSE with superior nerve conspicuity and greater subjective appeal. Prospective, cross-sectional study. Twenty-four subjects (16 females; mean age: 43.7 years; range: 19-76 years) evaluated for clinical suspicion of brachial plexopathy, undergoing brachial plexus MRI (10 left, 9 right, 5 bilateral, 29 total scans analyzed). Agar phantoms mimicking nerve and muscle were also evaluated. 3-Tesla, 3D STIR-TSE with and without VERSE. Three radiologists, blinded to the sequence type and clinical data, qualitatively evaluated nerve conspicuity, motion, and preferred sequence on a 5-point scale. Wilcoxon signed-rank tests compared nerve conspicuity (0-4 scale), motion artifact (0-4 scale), and preferred series between the non-VERSE and VERSE pulse sequences. Gwet's AC2 assessed inter-rater agreement. A p-value < 0.05 was considered statistically significant. The VERSE STIR-TSE sequence was significantly preferred by all raters. Motion artifact was not significantly different between the sequences (p = 0.11). Conspicuity of the suprascapular nerve was significantly greater with VERSE for both its proximal segments (median: 3, interquartile range: (2, 4), vs. 3 (1, 4)) and distal segments (4 (2, 4) vs. 3 (2, 4)), but conspicuity of the axillary nerve was not significantly different between the sequences (p = 0.27-0.61). Phantom scans confirmed a 74% and 49% increase in signal with VERSE in the muscle and nerve-mimicking phantoms, respectively. STIR-TSE with VERSE provided overall superior image quality for brachial plexus MRN as compared to conventional STIR-TSE. 2. 1.
Read more