• Home
  • Search
  • Feasibility of Second Harmonic Imaging in Active Sonar: Measurements and Simulations
  • Open Access IconOpen Access
  • Cite Icon20
  • https://doi.org/10.1109/joe.2012.2198933Copy DOI Icon

Feasibility of Second Harmonic Imaging in Active Sonar: Measurements and Simulations

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Nonlinear acoustics allows for applications like tissue harmonic imaging in medicine and parametric arrays in underwater acoustics. Mainstream sonars transmit and receive signals at the same frequency and up to now energy transferred to higher harmonic frequencies has been mainly seen as a disturbance for target strength estimation, e.g., in fishery research. This paper investigates the feasibility of utilizing the part of the signal generated around the second harmonic frequency band by nonlinear propagation of sound in water. It presents the potential enhancements the second harmonic signal may provide for target imaging as well as multifrequency target recognition. It compares measurements of the pressure field radiated by commercial transducers in water at 121 and 200 kHz up to a range of 12 m with numerical simulations. The detected levels of higher harmonic signals agree with simulations of nonlinear wave propagation. This verifies the implementation of the simulator and allows a comparison of the beam characteristics at longer ranges when filtered around the fundamental or second harmonic frequencies. An example of pulse-echo imaging with spherical targets is also shown using signals at the fundamental and second harmonic frequencies where the second harmonic signal can detect one of the targets that the fundamental signal cannot. Using the active sonar equation to estimate the maximum range, simulations based on a simple model including ambient noise and volume reverberation confirm that with a source level of 228 dB and a detection threshold of 12 dB the fundamental signal at 200 kHz can detect a fish of target strength -36 dB to approximately 343 m while the detection range of the second harmonic signal is approximately 243 m. The combined use of the signal components in the second harmonic and fundamental frequency bands provides a high-resolution image at short range and a long-range imaging capability at a lower resolution as well as a multifrequency characterization of targets.

Similar Papers
  • Research Article
  • Citations1

Tissue harmonic imaging based on the fourth harmonic: a simulation study

  • Aug 01, 2012
  • The Imaging Science Journal
  • A Baniasadipour +1
  • Front Matter
  • Citations6

Second harmonic imaging: Good reverberations

  • Jul 01, 1999
  • American Heart Journal
  • Linda J Crouse +1
  • Conference Article

A novel method for separating harmonic from ultrasonic echo signals using improved complete ensemble empirical mode decomposition with adaptive noise algorithm

  • Oct 01, 2017
  • Suya Han +4
  • Conference Article

Design of 94GHz High Efficiency Rectifier MMIC

  • Nov 28, 2021
  • Ren Furumoto +2
  • Research Article
  • Citations20

Tissue Harmonic Imaging

  • May 01, 2005
  • Journal of Diagnostic Medical Sonography
  • W R Hedrick +1
  • Conference Article
  • Citations21

A Ka-band quadruple-push oscillator

  • Jun 08, 2003
  • H Xiao +2
  • Research Article
  • Citations17

New Time-Domain Voltage and Current Waveform Measurement Setup for Power Amplifier Characterization and Optimization

  • Jan 01, 2008
  • IEEE Transactions on Microwave Theory and Techniques
  • Souheil Bensmida +4
  • Conference Article
  • Citations12

Nonlinear wave propagation - a fast 3D simulation method based on quasi-linear approximation of the second harmonic field

  • Oct 08, 2002
  • H Torp +2
  • Preprint Article

Volcanic harmonic tremors during a non-eruptive event, Torfajokull volcano, Iceland

  • Mar 28, 2022
  • Joana Martins +2
  • Research Article
  • Citations3

A Signal Detection Method for Harmonic Signal Submerged in Complex Noise Background

  • Sep 01, 2013
  • Applied Mechanics and Materials
  • Ai Juan Quan +2
  • Research Article
  • Citations23

Synthetic aperture imaging of contact acoustic nonlinearity to visualize the closing interfaces using tone-burst ultrasonic waves

  • Aug 23, 2018
  • Mechanical Systems and Signal Processing
  • Hogeon Seo +2
  • Research Article
  • Citations5

Dual-frequency tissue harmonic suppression using phase-coded pulse sequence: Proof of concept using a phantom

  • Nov 09, 2012
  • Ultrasonics
  • Che-Chou Shen +1
  • Research Article
  • Citations2

ADVANCED METHOD OF PROTECTION OF CONFIDENTIAL INFORMATION FROM INTERCEPTION BY HIGH-FREQUENCY IMPOSITION METHODS

  • Apr 14, 2022
  • Computer systems and information technologies
  • Larysa Kriuchkova +2
  • Research Article

Active Control of Periodic Noise with High-Order Harmonic Frequencies. Control Performance Improvement using a Spectrum-Shaping Method.

  • Jan 01, 1997
  • TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
  • Mitsuru Nakamura +4
  • Research Article
  • Citations11

Design of multioctave high‐efficiency power amplifier based on extended continuous Class‐B/J modes

  • Jul 16, 2019
  • International Journal of RF and Microwave Computer-Aided Engineering
  • Xuefei Xuan +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.