• Home
  • Search
  • Fiber motion-insensitive fiber-based polarization-sensitive optical coherence tomography for optic axis determination
  • Cite Icon3
  • https://doi.org/10.1364/josab.376808Copy DOI Icon

Fiber motion-insensitive fiber-based polarization-sensitive optical coherence tomography for optic axis determination

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Polarization-sensitive optical coherence tomography (PS-OCT) is widely used to image fibrous biological tissues, providing additional image contrast compared to intensity-based OCT, including birefringence and optic axis orientation information. Here a theoretical and experimental analysis of the effect of the system fiber on determination of sample optic axis orientation using a previously reported algorithm based on the angle between Stokes vectors on the Poincaré sphere in fiber-based PS-OCT experimentally confirms that the algorithm only works correctly when the parameters of the system fiber are kept constant during the imaging acquisition of each frame. To extend the use of the algorithm to situations in which the parameters of the system fiber are varied among A-scans or image frames, which is true when the OCT probe scanning does move the sample arm fiber, we propose the use of polarization maintaining fiber (PMF) with a special polarization axis orientation as the sample arm fiber for extracting sample optic axis orientation using fiber-based PS-OCT systems. The use of the PMF makes the system insensitive to variations of the sample fiber birefringence for determining optic axis orientation by automatically removing the offset ambiguity from each A-scan. We demonstrated by using a computer evaluation model that the proposed method is capable of extracting the relative optic axis orientation correctly when the PMF birefringence is varied among A-scans due to external disturbances to the system fiber, provided that the polarization axis orientation (slow or fast) of the PMF is kept constant during the measurement.

Similar Papers
  • Research Article
  • Citations530

Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography

  • Dec 17, 2001
  • Optics Express
  • Christoph Hitzenberger +4
  • Research Article

Polarization-Sensitive Module for Optical Coherence Tomography Instruments.

  • Nov 30, 2025
  • ArXiv
  • Po-Yi Lee +6
  • PDF
  • Research Article
  • Citations1

The Casimir Effect between Parallel Plates Separated by Uniaxial Media: The Effects Due to the Orientation of the Optical Axis

  • May 01, 2023
  • Universe
  • Gang Deng +4
  • Conference Article

Guiding Deep Brain Stimulation Neurosurgery using Polarization Sensitive Optical Coherence Tomography (PS-OCT)

  • May 31, 2021
  • Shadi Masoumi +1
  • Research Article
  • Citations159

Polarization sensitive optical coherence tomography of melanin provides intrinsic contrast based on depolarization

  • Jun 21, 2012
  • Biomedical Optics Express
  • Bernhard Baumann +10
  • Research Article
  • Citations179

Polarization-sensitive swept-source optical coherence tomography with continuous source polarization modulation

  • Apr 11, 2008
  • Optics Express
  • Masahiro Yamanari +2
  • Research Article
  • Citations38

Characterizing of tissue microstructure with single-detector polarization-sensitive optical coherence tomography

  • Jun 20, 2006
  • Applied Optics
  • Bin Liu +7
  • Research Article
  • Citations10

PM fiber based sensing tapes with automated 45° birefringence axis alignment for distributed force/pressure sensing.

  • Jun 09, 2020
  • Optics Express
  • Peng Hao +7
  • Research Article
  • Citations51

Automated Identification and Quantification of Subretinal Fibrosis in Neovascular Age-Related Macular Degeneration Using Polarization-Sensitive OCT.

  • Apr 11, 2016
  • Investigative Opthalmology & Visual Science
  • Philipp Roberts +8
  • Conference Article
  • Citations4

Evaluation of osteoarthritis progression using polarization-sensitive optical coherence tomography

  • Jul 01, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Nader A Nassif +4
  • Conference Article
  • Citations3

Imaging of polarization properties of the human cornea with phase resolved polarization sensitive optical coherence tomography

  • Jul 14, 2003
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Erich Gotzinger +7
  • Conference Article

Polarization sensitive en face optical coherence tomography using multichannel acousto-optic deflectors

  • Mar 20, 2013
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Mantas Zurauskas +2
  • Conference Article
  • Citations2

Retinal pigment epithelium pathologies investigated with phase resolved polarization sensitive optical coherence tomography

  • Feb 09, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • M Pircher +6
  • Conference Article

Polarization-sensitive swept-source optical coherence tomography at 1µm for birefringence imaging of the posterior segment of the eye

  • Feb 12, 2009
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Masahiro Yamanari +2
  • Research Article
  • Citations64

Determination of characteristics of degenerative joint disease using optical coherence tomography and polarization sensitive optical coherence tomography

  • Jan 01, 2006
  • Lasers in Surgery and Medicine
  • Tuqiang Xie +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.