• Home
  • Search
  • Polarization-Sensitive Module for Optical Coherence Tomography Instruments.

    Polarization-Sensitive Module for Optical Coherence Tomography Instruments.

    • Nov 30, 2025
    • ArXiv
    • Po-Yi Lee +6 more
    Show More
    • Abstract
    • Literature Map
    • Similar Papers
    Abstract

    Polarization-sensitive optical coherence tomography (PS-OCT) extends OCT by analyzing the polarization states of backscattered light to quantify tissue birefringence. However, conventional implementations require polarization-diverse detection and are therefore incompatible with most commercial OCT systems. As a result, PS-OCT has largely remained restricted to specialized research groups, limiting its broader scientific and clinical use. Here, we present a modular PS-OCT framework that integrates with a standard spectral-domain OCT platform through a detachable rotating achromatic half-wave plate in the sample arm. This waveplate modulates both incident and reflected polarization states. Three or more repeated measurements at distinct waveplate orientations enable reconstruction of the sample's round-trip Jones matrix and the corresponding polarization properties. To mitigate random phase variations between repeated measurements, we introduce a retarder-constrained phase optimization strategy. We validate the framework with imaging of birefringent phantoms and the human retina in vivo, demonstrating reliable reconstruction of retardance and optic axis orientation. This approach requires only minimal hardware modification and is readily deployable on mainstream OCT systems. Lowering technical barriers paves the way for rapid and widespread deployment of PS-OCT across diverse biomedical applications in both research and clinical environments.

    Similar Papers
    • Conference Article

    Polarization-sensitive swept-source optical coherence tomography for investigating depth, birefringence, depolarization and orientation of collagen structure of human cervix tissue

    • Feb 22, 2019
    • Brenda F Narice +3
    • Research Article
    • Citations530

    Measurement and imaging of birefringence and optic axis orientation by phase resolved polarization sensitive optical coherence tomography

    • Dec 17, 2001
    • Optics Express
    • Christoph Hitzenberger +4
    • Research Article
    • Citations159

    Polarization sensitive optical coherence tomography of melanin provides intrinsic contrast based on depolarization

    • Jun 21, 2012
    • Biomedical Optics Express
    • Bernhard Baumann +10
    • Conference Article
    • Citations3

    Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT)

    • Feb 09, 2006
    • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
    • Susanne D Giattina +8
    • Research Article
    • Citations38

    Characterizing of tissue microstructure with single-detector polarization-sensitive optical coherence tomography

    • Jun 20, 2006
    • Applied Optics
    • Bin Liu +7
    • Conference Article
    • Citations2

    Retinal pigment epithelium pathologies investigated with phase resolved polarization sensitive optical coherence tomography

    • Feb 09, 2006
    • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
    • M Pircher +6
    • Conference Article

    Guiding Deep Brain Stimulation Neurosurgery using Polarization Sensitive Optical Coherence Tomography (PS-OCT)

    • May 31, 2021
    • Shadi Masoumi +1
    • Research Article
    • Citations24

    Repeatability of corneal phase retardation measurements by polarization-sensitive optical coherence tomography.

    • May 20, 2015
    • Investigative ophthalmology & visual science
    • Shinichi Fukuda +8
    • PDF
    • Research Article
    • Citations172

    Polarization Sensitive Optical Coherence Tomography: A Review of Technology and Applications

    • May 04, 2017
    • Applied Sciences
    • Bernhard Baumann
    • Research Article
    • Citations492

    Imaging caries lesions and lesion progression with polarization sensitive optical coherence tomography.

    • Jan 01, 2002
    • Journal of Biomedical Optics
    • Daniel Fried +5
    • Research Article
    • Citations64

    Determination of characteristics of degenerative joint disease using optical coherence tomography and polarization sensitive optical coherence tomography

    • Jan 01, 2006
    • Lasers in Surgery and Medicine
    • Tuqiang Xie +4
    • Research Article
    • Citations3

    Fiber motion-insensitive fiber-based polarization-sensitive optical coherence tomography for optic axis determination

    • Feb 06, 2020
    • Journal of the Optical Society of America B
    • Zenghai Lu +1
    • Research Article
    • Citations11

    Polarization properties of retinal blood vessel walls measured with polarization sensitive optical coherence tomography.

    • Jun 23, 2021
    • Biomedical Optics Express
    • Hadi Afsharan +8
    • Research Article
    • Citations16

    Constrained polarization evolution simplifies depth-resolved retardation measurements with polarization-sensitive optical coherence tomography.

    • Sep 17, 2019
    • Biomedical Optics Express
    • Qiaozhou Xiong +7
    • Research Article
    • Citations8

    Analysis and reduction of noise-induced depolarization in catheter based polarization sensitive optical coherence tomography.

    • Mar 17, 2022
    • Optics Express
    • Qingrui Li +9
    Cactus Communications logo

    Copyright 2026 Cactus Communications. All rights reserved.