• Home
  • Search
  • Four-Dimensional Flow in Fontan Patients: Advanced Haemodynamic Assessment.
  • Cite Icon1
  • https://doi.org/10.3390/jcm14113801Copy DOI Icon

Four-Dimensional Flow in Fontan Patients: Advanced Haemodynamic Assessment.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Staged palliation with the creation of a Fontan circulation is the standard surgical approach in patients with a single ventricle. The Fontan circulation is a complex circuit that is associated with various complications that may present early or later in life and can limit life quality and expectancy. In this context, a good understanding of the Fontan physiology is important to improve outcomes for single-ventricle patients. Cardiovascular magnetic resonance (CMR) is recommended for the long-term follow-up of Fontan patients, as it provides functional and haemodynamic information. Four-dimensional (4D) Flow MRI is a time-resolved, three-dimensional, velocity-encoded cardiovascular magnetic resonance technique that is increasingly used in Fontan patients because it not only enables measuring blood flow within a three-dimensional (3D) volume, but also allows for assessing more advanced haemodynamic parameters that may help in understanding the Fontan physiology and pathophysiology. Furthermore, 4D Flow is used for image-based simulations using computational fluid dynamics. In this review, we provide an overview of the use of cardiovascular magnetic resonance flow assessment, with a focus on four-dimensional flow ('4D Flow').

Similar Papers
  • Research Article
  • Citations5

Assessment of hepatic arterial hemodynamics with 4D flow MRI: in vitro analysis of motion and spatial resolution related error and in vivo feasibility study in 20 volunteers.

  • Jun 22, 2022
  • European Radiology
  • Ivan P Dimov +9
  • Research Article
  • Citations14

Four-dimensional Flow MRI-based Computational Fluid Dynamics Simulation for Noninvasive Portosystemic Pressure Gradient Assessment in Patients with Cirrhosis and Transjugular Intrahepatic Portosystemic Shunt.

  • Oct 01, 2024
  • Radiology
  • Christoph Riedel +11
  • Research Article
  • Citations4

Combined free-running four-dimensional anatomical and flow magnetic resonance imaging with native contrast using Synchronization of Neighboring Acquisitions by Physiological Signals

  • Jan 01, 2024
  • Journal of Cardiovascular Magnetic Resonance
  • Mariana B L Falcão +13
  • PDF
  • Research Article
  • Citations27

Stress increases intracardiac 4D flow cardiovascular magnetic resonance -derived energetics and vorticity and relates to VO2max in Fontan patients

  • Jan 01, 2019
  • Journal of Cardiovascular Magnetic Resonance
  • Vivian P Kamphuis +10
  • Research Article

Flow pattern analysis of right ventricular outflow tract in repaired tetralogy of Fallot through 4D flow MRI.

  • Feb 18, 2024
  • Heart and vessels
  • Noriyuki Iwashita +3
  • Research Article
  • Citations164

Four-dimensional Flow MRI: Principles and Cardiovascular Applications.

  • Mar 22, 2019
  • RadioGraphics
  • Arshid Azarine +8
  • PDF
  • Research Article
  • Citations5

4D-Flow Cardiovascular Magnetic Resonance Sequence for Aortic Assessment: Multi-Vendor and Multi-Magnetic Field Reproducibility in Healthy Volunteers

  • Apr 19, 2023
  • Journal of Clinical Medicine
  • Bruna Punzo +8
  • Research Article
  • Citations2

Fully automated on-scanner aortic four-dimensional flow magnetic resonance imaging processing and hemodynamic analysis

  • Jan 01, 2025
  • Journal of Cardiovascular Magnetic Resonance
  • Justin Baraboo +5
  • Research Article

A novel approach in the assessment of paravalvular regurgitation after transcatheter aortic valve replacement using cardiac magnetic resonance imaging

  • Jun 19, 2023
  • European Heart Journal - Cardiovascular Imaging
  • M J P Rooijakkers +5
  • Research Article
  • Citations8

Brand ferumoxytol vs. generic ferumoxytol comparison across two dosing regimens: a cardiac MRI image quality study.

  • Oct 14, 2023
  • Pediatric Radiology
  • Anoushka Dasi +7
  • Research Article
  • Citations1

Assessment of hemodynamic disturbances and impaired ventricular filling in asymptomatic fontan patients: A 4D flow CMR study.

  • Jun 01, 2025
  • European journal of radiology open
  • Li-Wei Hu +9
  • Research Article

Rapid slice-to-volume four-dimensional flow in pediatric congenital heart disease: a feasibility study

  • Jan 01, 2025
  • Journal of Cardiovascular Magnetic Resonance
  • Valérie Béland +5
  • Research Article
  • Citations5

Evaluation of left ventricular blood flow kinetic energy in patients with hypertension by four-dimensional flow cardiovascular magnetic resonance imaging: a preliminary study.

  • Feb 24, 2023
  • European Radiology
  • Kun Peng +10
  • PDF
  • Research Article
  • Citations3

Quantification of systemic-to-pulmonary collateral flow in univentricular physiology with 4D flow MRI.

  • Sep 19, 2022
  • Cardiology in the Young
  • Floris-Jan S Ridderbos +6
  • Research Article

Coprime dual-velocity encoding for extended velocity dynamic range in 4D flow magnetic resonance imaging

  • Jan 01, 2025
  • Journal of Cardiovascular Magnetic Resonance
  • Marta Beghella Bartoli +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.