• Home
  • Search
  • Four-dimensional Flow MRI: Principles and Cardiovascular Applications.
  • Open Access IconOpen Access
  • Cite Icon164
  • https://doi.org/10.1148/rg.2019180091Copy DOI Icon

Four-dimensional Flow MRI: Principles and Cardiovascular Applications.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

In-plane phase-contrast (PC) imaging is now a routine component of MRI of regional blood flow in the heart and great vessels. In-plane PC MRI provides a volumetric, isotropic, time-resolved cine sequence that enables three-directional velocity encoding, a technique known as four-dimensional (4D) flow MRI. Recent advances in 4D flow MRI have shortened imaging times, while progress in big-data processing has improved dataset pre- and postprocessing, thereby increasing the feasibility of 4D flow MRI in clinical practice. Important technical issues include selection of the optimal velocity-encoding sensitivity before acquisition and preprocessing of the raw data for phase-offset corrections. Four-dimensional flow MRI provides unprecedented capabilities for comprehensive analysis of complex blood flow patterns using new visualization tools such as streamlines and velocity vectors. Retrospective multiplanar navigation enables flexible retrospective flow quantification through any plane across the volume with good accuracy. Current flow parameters include forward flow, reverse flow, regurgitation fraction, and peak velocity. Four-dimensional flow MRI also supplies advanced flow parameters of use for research, such as wall shear stress. The vigorous burgeoning of new applications indicates that 4D flow MRI is becoming an important imaging modality for cardiovascular disorders. This article reviews the main technical issues of 4D flow MRI and the different parameters provided by it and describes the main applications in cardiovascular diseases, including congenital heart disease, cardiac valvular disease, aortic disease, and pulmonary hypertension. Online supplemental material is available for this article. ©RSNA, 2019 See discussion on this article by Ordovas .

Similar Papers
  • Research Article
  • Citations5

Assessment of hepatic arterial hemodynamics with 4D flow MRI: in vitro analysis of motion and spatial resolution related error and in vivo feasibility study in 20 volunteers.

  • Jun 22, 2022
  • European Radiology
  • Ivan P Dimov +9
  • Research Article
  • Citations14

Four-dimensional Flow MRI-based Computational Fluid Dynamics Simulation for Noninvasive Portosystemic Pressure Gradient Assessment in Patients with Cirrhosis and Transjugular Intrahepatic Portosystemic Shunt.

  • Oct 01, 2024
  • Radiology
  • Christoph Riedel +11
  • Research Article
  • Citations1

Four-Dimensional Flow in Fontan Patients: Advanced Haemodynamic Assessment.

  • May 29, 2025
  • Journal of clinical medicine
  • Dominik Daniel Gabbert +2
  • Research Article
  • Citations24

4D flow MRI assessment of extracranial-intracranial bypass: qualitative and quantitative evaluation of the hemodynamics.

  • Dec 02, 2015
  • Neuroradiology
  • Tetsuro Sekine +6
  • PDF
  • Research Article
  • Citations25

Fetal 4D flow MRI of the great thoracic vessels at 3 Tesla using Doppler-ultrasound gating: a feasibility study

  • Oct 22, 2022
  • European Radiology
  • J Knapp +9
  • Research Article
  • Citations4

Combined free-running four-dimensional anatomical and flow magnetic resonance imaging with native contrast using Synchronization of Neighboring Acquisitions by Physiological Signals

  • Jan 01, 2024
  • Journal of Cardiovascular Magnetic Resonance
  • Mariana B L Falcão +13
  • PDF
  • Research Article
  • Citations3

Quantification of systemic-to-pulmonary collateral flow in univentricular physiology with 4D flow MRI.

  • Sep 19, 2022
  • Cardiology in the Young
  • Floris-Jan S Ridderbos +6
  • Research Article
  • Citations23

4D flow MR imaging of the portal venous system: a feasibility study in children.

  • May 18, 2016
  • European Radiology
  • Keyur Parekh +5
  • Research Article
  • Citations16

4D Flow MR Imaging of Ophthalmic Artery Flow in Patients with Internal Carotid Artery Stenosis

  • Mar 27, 2017
  • Magnetic Resonance in Medical Sciences
  • Tetsuro Sekine +7
  • Research Article
  • Citations13

Hypertrophic Cardiomyopathy Is Associated with Altered Left Ventricular 3D Blood Flow Dynamics.

  • Feb 01, 2020
  • Radiology. Cardiothoracic imaging
  • Judith T Pruijssen +7
  • Conference Article

Evaluation of Regurgitation Fraction in Repaired Tetralogy of Fallot Using 2D-PC and 4D Flow MRI

  • Sep 16, 2025
  • Proceedings on CD-ROM - International Society for Magnetic Resonance in Medicine. Scientific Meeting and Exhibition/Proceedings of the International Society for Magnetic Resonance in Medicine, Scientific Meeting and Exhibition
  • H Mori +3
  • Research Article
  • Citations7

3D Vortex-Energetics in the Left Pulmonary Artery for Differentiating Pulmonary Arterial Hypertension and Pulmonary Venous Hypertension Groups Using 4D Flow MRI.

  • Oct 28, 2024
  • Journal of magnetic resonance imaging : JMRI
  • Mohammed S M Elbaz +8
  • Research Article
  • Citations12

Novel and facile criterion to assess the accuracy of WSS estimation by 4D flow MRI.

  • Jan 31, 2019
  • Medical Image Analysis
  • Seungbin Ko +4
  • Research Article
  • Citations7

Sildenafil administration improves right ventricular function on 4D flow MRI in young adults born premature.

  • Apr 16, 2021
  • American Journal of Physiology-Heart and Circulatory Physiology
  • Philip A Corrado +4
  • Research Article

Flow pattern analysis of right ventricular outflow tract in repaired tetralogy of Fallot through 4D flow MRI.

  • Feb 18, 2024
  • Heart and vessels
  • Noriyuki Iwashita +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.