At the Istituto Nazionale di Fisica Nucleare – Laboratori Nazionali del Sud (INFN-LNS) the beam commissioning of the high intensity Proton Source (PS-ESS) and the Low Energy Beam Transport (LEBT) line for the European Spallation Source (ESS) has been completed. The official project schedule was satisfied and the packaging for the shipment to Lund will shortly begin. Due to the high flexibility of the magnetic system, and to the innovative approach developed for the commissioning, we were able to test a huge amount of configurations (more than 400˙000). The optimum source configuration that satisfy all requirements at the same time has been identified. The source is able to produce a stable total current between 40 and 125 mA (90 mA requested) through an 8 mm extraction aperture, with a proton fraction of up to 87% (75% requested). At the end of the LEBT the beam characteristics fully satisfy the ESS requirements: more than 70 mA of proton beam with 99% normalized beam emittance of 2.25 π.mm.mrad have been transported with intra pulse current fluctuation below ±1.5% (<±2% requested) and long term current fluctuation below ±3% (<±3.5% requested). High reliability of the overall system was measured with long duration test and fast beam recovery after vacuum break of 24 hours. Results and used strategy will be shown in details

Similar Papers
  • Research Article

An integrated tool for ion linac design

  • Feb 01, 2024
  • Journal of Instrumentation
  • Orhan Cakir +6
  • Research Article
  • Citations13

Improved design of proton source and low energy beam transport line for European Spallation Source

  • Dec 06, 2013
  • Review of Scientific Instruments
  • L Neri +12
  • Research Article

BEAM DYNAMICS ISSUES IN THE POST ACCELERATOR FOR THE RARE ISOTOPE ION BEAMS FROM ISOL SYSTEM IN RISP

  • Jul 01, 2014
  • JACOW
  • Ji-Gwang Hwang +8
  • Research Article
  • Citations42

Transport of intense ion beams and space charge compensation issues in low energy beam lines (invited)

  • Feb 01, 2012
  • Review of Scientific Instruments
  • N Chauvin +5
  • Conference Article
  • Citations9

Design of the prototype low energy beam transport line for the Spallation Neutron Source

  • Apr 08, 2008
  • D.W Cheng +7
  • Conference Article
  • Citations6

Design and testing of a DC ion injector suitable for accelerator-driven transmutation

  • Jan 01, 1995
  • AIP conference proceedings
  • J David Schneider +4
  • Research Article
  • Citations13

Deuteron injector for Peking University Neutron Imaging Facility project

  • Feb 01, 2012
  • Review of Scientific Instruments
  • H T Ren +10
  • Conference Article
  • Citations2

Design of a 35 keV LEBT for the new high intensity OPPIS at BNL

  • Mar 27, 1999
  • J Alessi +7
  • Research Article

Instrumentation for ion sources and low energy beam transport systems (invited) (abstract)a)

  • Mar 01, 1996
  • Review of Scientific Instruments
  • M Olivo
  • Research Article
  • Citations3

Low energy beam transport for HIDIF

  • May 01, 2001
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • O Meusel +3
  • Research Article
  • Citations4

Beam dynamics design of an RFQ for a planned accelerator, which uses a direct plasma injection scheme

  • Apr 16, 2008
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Zhou-Li Zhang +5
  • Research Article

Re-Commissioning the Front End Test Stand Negative Hydrogen Ion Source, Beam Transport and Interlocks

  • Jun 01, 2018
  • JACOW
  • Scott Lawrie +10
  • Research Article
  • Citations11

Comparison of extraction and beam transport simulations with emittance measurements from the ECR ion source venus**This Research was conducted at LBNL and was supported by the U.S. Department of Energy under ContractDE-AC02-05CH11231.

  • Dec 01, 2010
  • Journal of Instrumentation
  • D Winklehner +5
  • Conference Article
  • Citations2

Numerical simulation of multicomponent ion beams in transport lines

  • Jan 01, 1999
  • AIP conference proceedings
  • V Alexandrov +4
  • Research Article
  • Citations3

Commissioning of the 7 MeV H[formula omitted] linac injector for a 200 MeV proton synchrotron

  • Jul 23, 2022
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • Zhongming Wang +21
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.