Abstract

The purpose of this study was to evaluate the potential clinical value of spectral CT for image guidance during percutaneous thermal ablation, particularly investigating high monoenergetic (MonoE) for metal artifact reduction. A phantom experiment was performed in which an ablation probe was scanned in "continuous CT" (CCT) mode on a spectral CT scanner. ROI measurements quantified metal artifacts for conventional and MonoE CCT images. Subsequently, a retrospective reader study was conducted with 10 patient cases. Three radiologists reviewed cases to select the optimal MonoE setting and perform a Likert score rating (+2: MonoE preferred, -2: conventional preferred). Phantom measurements indicated a reduction in metal artifact for high MonoE (150keV: -46HU) relative to conventional CCT (-122HU). The MonoE setting preference was 151±21keV. The mean Likert score was 1.2±0.7. Radiologists indicated a perceived benefit of high MonoE CCT when probe placement was near a critical structure. This study indicates a clinical preference for high MonoE CCT compared with conventional CCT. Insofar as spectral CCT can be offered at a clinically feasible time frame, our results support the assessment of 150keV image to reduce metal artifact while maintaining satisfactory soft tissue contrast.

Similar Papers
  • Research Article
  • Citations40

Preoperative Breast MRI: Surgeons' Patient Selection Patterns and Potential Bias in Outcomes Analyses.

  • Dec 27, 2016
  • American Journal of Roentgenology
  • Jiyon Lee +6
  • Research Article

Spectral computed tomography thermometry for thermal ablation: applicability and needle artifact reduction.

  • Sep 01, 2025
  • Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
  • Lennart R Koetzier +8
  • Research Article
  • Citations3

PixelPrint: Generating Patient-Specific Phantoms for Spectral CT using Dual Filament 3D Printing.

  • May 06, 2024
  • Proceedings of SPIE--the International Society for Optical Engineering
  • Pouyan Pasyar +6
  • PDF
  • Research Article
  • Citations13

An additional tilted‐scan‐based CT metal‐artifact‐reduction method for radiation therapy planning

  • Dec 31, 2018
  • Journal of Applied Clinical Medical Physics
  • Changhwan Kim +7
  • PDF
  • Research Article
  • Citations131

Metal artifact reduction on cervical CT images by deep residual learning

  • Nov 27, 2018
  • BioMedical Engineering OnLine
  • Xia Huang +4
  • Conference Article
  • Citations5

Spectral CT metal artifact reduction with an optimization-based reconstruction algorithm

  • Mar 09, 2017
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Taly Gilat Schmidt +2
  • Research Article
  • Citations28

Sinogram + image domain neural network approach for metal artifact reduction in low-dose cone-beam computed tomography

  • Mar 13, 2021
  • Journal of Medical Imaging
  • Michael D Ketcha +7
  • Research Article
  • Citations49

Artifact reduction from dental implants using virtual monoenergetic reconstructions from novel spectral detector CT

  • Apr 27, 2018
  • European Journal of Radiology
  • Nils Große Hokamp +7
  • Research Article

Deep Learning Reconstruction Algorithm Combined With Smart Metal Artifact Reduction Technique Improves Image Quality of Upper Abdominal CT in Critically Ill Patients

  • Nov 20, 2024
  • Sichuan da xue xue bao. Yi xue ban = Journal of Sichuan University. Medical science edition
  • Yunlong Pan +6
  • PDF
  • Research Article
  • Citations2

Dual-Layer Spectral CT for in Vivo Thermometry During Thermal Ablation.

  • Dec 29, 2025
  • Cardiovascular and interventional radiology
  • Nicole A Varble +8
  • Research Article
  • Citations98

Spectral CT with Metal Artifacts Reduction Software for Improvement of Tumor Visibility in the Vicinity of Gold Fiducial Markers

  • Mar 13, 2012
  • Radiology
  • Olga R Brook +5
  • Research Article
  • Citations8

Metal artifacts from sternal wires: evaluation of virtual monoenergetic images from spectral-detector CT for artifact reduction

  • Jan 08, 2020
  • Clinical Imaging
  • Kai Roman Laukamp +8
  • Research Article
  • Citations6

A robust index for metal artifact quantification in computed tomography.

  • Jun 25, 2024
  • Journal of applied clinical medical physics
  • Jochen Cammin
  • PDF
  • Research Article
  • Citations10

Image quality and metal artifact reduction in total hip arthroplasty CT: deep learning-based algorithm versus virtual monoenergetic imaging and orthopedic metal artifact reduction

  • Mar 14, 2024
  • European Radiology Experimental
  • Mark Selles +7
  • Conference Article
  • Citations1

Metal Artifact Reduction by Using Dual-Energy Raw Data Constraint Learning

  • Oct 23, 2021
  • Fanning Kong +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.