MO‐D‐105‐06: Dose‐Area Product as a Method for Small Field Geometric QA

Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Purpose: To investigate the use of dose‐area product (DAP) as a highresolution tool for QA of small field sizes as an alternative to more complex alternatives such as film or water tank scanning. Method: An 81 mm diameter PTW Bragg Peak parallel plate chamber was used in combination with an Iris variable circular aperture collimator fitted to a CyberKnife System and a vendor‐supplied alignment jig. The Iris collimator is designed to deliver field diameters between 5 mm and 60 mm, with a tolerance of ±0.2 mm. First the sensitivity of the chamber reading to influence parameters (SSD, angle misalignment, lateral displacement, output variation) was investigated. Next the dependency of DAP on field diameter was investigated. Finally the sensitivity of the method to detect small field size changes consistent with the device specification was evaluated. Comparisons were made with film and diode water scans using four CyberKnife systems and three chambers. Results: Expected variations in chamber position/orientation within the jig resulted in measurement changes <0.2%. Measurement variations due to LINAC output changes can be removed by normalising measurements to a fixed collimator reading obtained at the same time. The variation in chamber reading with field size followed a quadratic dependency over the 5mm ‐ 60mm range. The change in chamber reading associated with a 0.2 mm field diameter change ranged from 10% at 5 mm nominal to 0.5% at 60 mm, and was reasonably consistent across tests performed on four units. Measurements were more consistent than routine film tests, and were stable over two years. Conclusion: DAP provides a practical, efficient, robust, and sensitive method for routine QA of field aperture changes as small as ±0.2mm across the field size range 5 mm – 60 mm. The method may also have applications for QA of small fields formed by MLC.

Similar Papers
  • Research Article
  • Citations7

Integral small field output factor measurements using a transmission ionisation chamber.

  • Nov 30, 2018
  • Australasian Physical & Engineering Sciences in Medicine
  • R De Chavez +2
  • Research Article

SU‐E‐T‐471: Small Field Jaw/MLC Reference Data

  • May 29, 2014
  • Medical Physics
  • J Kerns +6
  • Research Article
  • Citations48

The Effect of Agricultural Landscape Structure on Food Resources and Survival of Grey Partridge Perdix Perdix Chicks in Poland

  • Jun 01, 1997
  • The Journal of Applied Ecology
  • Marek Panek
  • Research Article

Explicit Constructions of Capacity-Achieving T-PIR Schemes Over Small Fields via Generalized Minor Matrices

  • Jul 01, 2025
  • IEEE Transactions on Information Theory
  • Jingke Xu +1
  • Research Article
  • Citations9

Evaluation of MRI-based MAGIC polymer gel dosimeter in small photon fields

  • Jan 01, 2016
  • Internatuinal Journal of Radiation Research
  • W Parwaie +5
  • Research Article
  • Citations4

Characterisation of small photon field outputs in a heterogeneous medium using X-ray voxel Monte Carlo dose calculation algorithm

  • Aug 23, 2017
  • Journal of Radiotherapy in Practice
  • Karthikeyan Nithiyanantham +6
  • Research Article
  • Citations57

Monte Carlo-based diode design for correction-less small field dosimetry

  • Jun 13, 2013
  • Physics in Medicine and Biology
  • P H Charles +7
  • Research Article

Evaluating equivalent square field size definitions for rectangular small fields

  • Feb 01, 2026
  • Journal of Applied Clinical Medical Physics
  • Ignasi Méndez +3
  • Research Article
  • Citations1

TH‐EF‐204‐02: Small Field Radiation Therapy: Physics and Recent Recommendations From IAEA and ICRU

  • Jun 01, 2016
  • Medical Physics
  • J Seuntjens
  • PDF
  • Research Article
  • Citations18

Deriving detector-specific correction factors for rectangular small fields using a scintillator detector.

  • Nov 01, 2016
  • Journal of Applied Clinical Medical Physics
  • Yujiao Qin +5
  • Research Article
  • Citations59

Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors

  • Sep 29, 2010
  • Medical Physics
  • David M Klein +5
  • Research Article

SU‐E‐J‐80: Small Beam Dosimetry Using MAGIC Gel with a 7T Micro‐MRI Scanner

  • Jun 01, 2011
  • Medical Physics
  • X Ding +6
  • Abstract
  • Citations1

Measurement, modelling and reporting of small field output factors requires systematic approaches for accurate dosimetry

  • Jan 01, 2014
  • Physica Medica
  • D.I Thwaites +3
  • Research Article
  • Citations29

Practical approach to electron beam dosimetry at extended SSD

  • Aug 01, 1997
  • Physics in Medicine & Biology
  • Joanna Cygler +3
  • Research Article
  • Citations1

MO‐G‐BRB‐02: Commissioning a Small Animal Irradiator Using 2D and 3D Dosimetry Techniques

  • Jun 01, 2011
  • Medical Physics
  • J Newton +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.