• Home
  • Search
  • Modulation of Human Intraocular Pressure Using a Pneumatic System.
  • Cite Icon4
  • https://doi.org/10.1167/tvst.10.14.4Copy DOI Icon

Modulation of Human Intraocular Pressure Using a Pneumatic System.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

PurposeTo technically validate a novel pneumatically based system and method for modulation of intraocular pressure (IOP) and to test its application in the human eye. Special attention was paid to the applicability of the pneumatically driven balloon, which realizes the modulation of the IOP through its contact with the conjunctiva.MethodsA force sensor as key component of a customized measurement setup was used to check the applied pressure through the balloon. The IOP of 10 healthy subjects (4 female, 6 male, aged 28.8 ± 6.64 years) was modulated and increased linearly to at least 40 mmHg. At this point, the pressure inside the balloon was kept constant for 2 minutes, with IOP measurements taken every 40 seconds using a rebound tonometer.ResultsThe technical setup led to an IOP decrease of 0.71 mmHg within 2 minutes at an operating point of 40 mmHg. For all subjects, the IOP could be increased up to 42.8 ± 3.6 mmHg, whereby a mean pressure decrease of 2.4 mmHg/min was determined, which seems to be caused mainly by physiological processes.ConclusionsWith the new pneumatically based setup, a targeted modulation in terms of level and constancy of the IOP can be realized.Translational RelevanceAdditional and, compared with the technique according to Löw, a more precise and more constant methodology for the modulation of the IOP, can significantly simplify the determination of retinal vessel pressures for clinical application. It is suitable for practical questions concerning an enhanced retinal venous pressure.

Similar Papers
  • Research Article
  • Citations34

Noninvasive Determination of Intraocular Pressure (IOP) in Nonsedated Mice of 5 Different Inbred Strains

  • Jan 01, 2007
  • Journal of Glaucoma
  • Nicholas Nissirios +4
  • Research Article
  • Citations136

The Induction/Impact Tonometer: a New Instrument to Measure Intraocular Pressure in the Rat

  • Dec 01, 2001
  • Experimental Eye Research
  • Antti I Kontiola +3
  • Research Article
  • Citations4

Intraocular Pressure Measurement with Pneumatonometry and a Tonometer Tip Cover During Negative Pressure Application.

  • Apr 01, 2022
  • Clinical Ophthalmology
  • Enrico Brambilla +4
  • Research Article
  • Citations4

Improved prediction of fellow-eye response in one-eye trials using multiple intraocular pressure measurements

  • Sep 01, 2011
  • Japanese Journal of Ophthalmology
  • Yuka Wakabayashi +2
  • Research Article
  • Citations44

The effect of corneal thickness and corneal curvature on pneumatonometer measurements

  • Jan 01, 2002
  • Current Eye Research
  • Andrew J Morgan +3
  • Research Article
  • Citations1

Effect of corneal cross linkage (CXL) on intraocular pressure (IOP) measurements in keratoconus patients

  • May 13, 2022
  • Advances in Ophthalmology & Visual System
  • Nusrat Waheed +6
  • Dissertation

Development of an inductive sensing contact lens sensor with environmental reference for continuous intraocular pressure monitoring

  • Jan 01, 2019
  • Christopher Ching Hymn Lee
  • Research Article
  • Citations8

Assessing Agreement and Variability Among Alternative Devices for Intraocular Pressure Measurement: A Comparative Study.

  • Nov 01, 2023
  • Clinical Ophthalmology
  • Chen-Wei Lin +4
  • Research Article
  • Citations11

The Effect of Periocular Negative Pressure Application on Intraocular and Retrobulbar Pressure in Human Cadaver Eyes

  • Dec 15, 2021
  • Ophthalmology and Therapy
  • Brian Shafer +4
  • Research Article

Comparison of Intraocular Pressure Measurement by Goldmann Applanation Tonometer and Air Puff Tonometer in Silicone Filled Eyes.

  • Aug 23, 2020
  • Benha Medical Journal
  • Ashraf El Shayeb +2
  • Research Article

Comparation between Keeler and ORA IOP measurements

  • Aug 06, 2012
  • Acta Ophthalmologica
  • C Lopez De La Fuente +4
  • Research Article
  • Citations17

Comparison of Diurnal Intraocular Pressure Control by Latanoprost versus Travoprost

  • Jan 01, 2006
  • Clinical Drug Investigation
  • Philippe Denis +3
  • Research Article
  • Citations5

Use of machine learning to predict the risk of early morningintraocular pressure peaks in glaucoma patients and suspects

  • Jan 01, 2021
  • Arquivos Brasileiros de Oftalmologia
  • Camilo Brandão-De-Resende +6
  • Research Article
  • Citations29

Effect of Riboflavin-UVA–Induced Collagen Cross-linking on Intraocular Pressure Measurement

  • Dec 01, 2007
  • Investigative Opthalmology & Visual Science
  • Timo Romppainen +5
  • Research Article
  • Citations34

Intraocular pressure control after clear corneal phacoemulsification in eyes with previous trabeculectomy: a controlled study

  • Jul 26, 2005
  • Acta Ophthalmologica Scandinavica
  • Asli Inal +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.