• Home
  • Search
  • Modulation transfer function evaluation of linear solid-state x-ray-sensitive detectors using edge techniques
  • Cite Icon11
  • https://doi.org/10.1364/ao.34.004937Copy DOI Icon

Modulation transfer function evaluation of linear solid-state x-ray-sensitive detectors using edge techniques

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The exact determination of the modulation transfer function (MTF) of a physical system is a persistent problem. We present a practical method of measuring numerically the MTF of linear solid-state x-ray-sensitive detectors. The method is based on the use of edge techniques and allows us to obtain the MTF of a linear detector from its edge-spread function (ESF). ESF measurement techniques are discussed in detail, and calculation of the corresponding MTF's are shown.

Similar Papers
  • Research Article
  • Citations3

Effects of processing steps with an edge image on determining the presampled modulation transfer function

  • Jul 01, 2012
  • Journal of the Korean Physical Society
  • Ye-Seul Kim +2
  • Conference Article
  • Citations10

Novel algorithm for measuring the MTF of a digital radiographic system with a CCD array detector

  • Apr 25, 2000
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Xinhua Cao +2
  • Conference Article
  • Citations5

A simple edge device method for determining the presampling modulation transfer function (MTF) of flat field digital detectors

  • Apr 20, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Beilei Wang +4
  • Conference Article

<title>Using a rotating test pattern for MTF measurement of staring array sensors</title>

  • Aug 05, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jonathan D Fanning +2
  • Conference Article
  • Citations7

A software tool for measurement of the modulation transfer function

  • Apr 20, 2005
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yen-Hong Kao +4
  • Research Article
  • Citations37

Accurate MTF measurement in digital radiography using noise response.

  • Jan 22, 2010
  • Medical Physics
  • Andrew Kuhls-Gilcrist +4
  • Book Chapter

Optical Systems With Circular Pupils

  • Aug 04, 2011
  • Virendra N Mahajan
  • Conference Article
  • Citations3

High-resolution satellite image recovery by modulation transfer function (MTF) compensation method using phase congruency estimation

  • Sep 24, 2013
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Xiaopeng Shao +4
  • Conference Article

MTF simulation of a-Se x-ray detector using ARTEMIS for breast imaging applications

  • Nov 01, 2018
  • Yu-Han Cheng +3
  • Conference Article
  • Citations18

Investigation of imaging performance of amorphous selenium flat-panel detectors for digital mammography

  • Jun 28, 2001
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Wei Zhao +3
  • PDF
  • Research Article
  • Citations46

An algorithm for automated modulation transfer function measurement using an edge of a PMMA phantom: Impact of field of view on spatial resolution of CT images

  • Oct 19, 2018
  • Journal of Applied Clinical Medical Physics
  • Choirul Anam +4
  • Conference Article
  • Citations3

Lunar-edge based on-orbit modulation transfer function (MTF) measurement

  • Oct 24, 2017
  • Ying Cheng +2
  • Research Article
  • Citations9

Optical transfer function analysis of circular-pupil wavefront coding systems with separable phase masks

  • Jun 01, 2012
  • Chinese Physics B
  • Ting-Yu Zhao +2
  • Conference Article

Study of correlation between MTF and extended source encircled energy through Monte-Carlo simulation and measured data

  • Aug 20, 2020
  • David P Biss +1
  • Abstract
  • Citations2

Detective quantum efficiency (DQE) of the Dexela 2923MAM detector according to IEC 62220-1-1:2015

  • Aug 26, 2016
  • Physica Medica
  • V Koukou +10
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.