- Book Chapter
11
- 10.1016/b978-044450810-2/50006-3
Chapter 4 - Multiple Effect Evaporation
- Jan 01, 2002
- Fundamentals of Salt Water Desalination
- Hisham El-Dessouky + 1 more +1
Chapter 4 - Multiple Effect Evaporation
Multiple-effect evaporation desalination systems. thermal analysis
Chapter 4 - Multiple Effect Evaporation
Chapter 4 - Multiple Effect Evaporation
Visual basic computer package for thermal and membrane desalination processes
Visual basic computer package for thermal and membrane desalination processes
Simulation with Aspen Plus and Performance Analysis of LT-MED Seawater Desalination System
With Aspen Plus, three simulation models for Low-Temperature Multi-Effect Distillation (LT-MED) seawater desalination system are established in this work, which includes the parallel flow, forward flow and backward flow processes. Performance analysis including the motive steam flow, Gained Output Ratio (GOR) and heat transfer area are conducted as a function of the process type, number of effects, heating steam temperature and the effect NO. for Thermal Vapor Compression (TVC) ejection. Results indicate that the established simulation models are accurate and reliable; the process type, the number of effects and the effect NO. for TVC ejection have a great impact on the performance, while the effect of heating steam temperature on the performance is relatively weaker.
Read moreSteady-state analysis of multi-stage flash desalination process
Steady-state analysis of multi-stage flash desalination process
Thermoeconomic Analysis of a Solar MVC Desalination System
Globally, about 10% of the world population does not have access to enough fresh water. In many hot-and-dry coastal regions and islands, the desalination of seawater might be the only practical option to have a fresh water supply. Therefore, low-cost desalination system is critical for freshwater demands. To address this issue, a desalination system consisting of solar photovoltaic (PV) and mechanical vapor compression subsystem is proposed in this study. The entire desalination system was modeled and designed to produce 10,000 m3 of fresh water per day at the coast of San Francisco, California. Key components such as water vapor compressor, solar PV panel, and three-stream heat recovery unit were designed, and their performances were analyzed. The effects of design variables and operating conditions on the system performance were investigated through a parametric study. Finally, an economic analysis was conducted and compared with current desalination technologies. The analysis results show that the specific power consumption of desalination system can reach 14.4 kWh/m3 when the evaporation temperature is 70°C. It is found that the evaporating temperature has a great influence on the heat pump system efficiency and evaporator design. The levelized cost of the proposed system is $0.76 per m3 of fresh water which is lower than current grid-powered vapor compression desalination system and other thermal desalination systems. The proposed solar PV driven desalination improves thermoeconomics of desalination system by applying low-lift operating condition to the vapor compression cycle so that it can contribute to solving the fresh water supply challenges.
Read moreSeawater feed reverse osmosis preheating appraisal, Part II: system performance
The present work evaluates the seawater feed Reverse Osmosis (RO) preheating system process. In this respect, the basic transport equations, which describe the system elements, are used for determining the performance of the process operating parameters and for assessing the feed preheating process. A seawater membrane, FTSW30HR-380, was used to perform this study. In Part I of the work, the leading element, which governs the whole system, was studied. Also, the limitations of the leading element operating parameters were determined. In the recent work, a computer program is developed using the RO-governing process equations to obtain the system design and projection for the seawater feed preheating assessment, which enabled the determination of the whole system by solving the system elements, one by one. Also, an evaluation of the power needed for freshwater production. The RO system feed preheating is studied for feed temperatures ranging from 15°C to 45°C. The study shows that the permeate salt concentration increases as the feed temperature increases and the system salt rejection decreases. The present study concluded that the permeate productivity decreases with the increase in the feed temperature. Results also show that the product's specific power consumption is dependent on the number of elements used, and energy recovery. In the case of the maximum available number of elements, it is found that the feed temperature increases as the specific power consumption increases, with or without brine pressure energy recovery. However, in the case of a constant number of elements, seven elements, the specific power consumption decreases as the feed temperature increases.
Read moreCalculation and Analysis of the Relationship Between the Efficiency and Position of Electric Arcs and Power Consumption in Electric Arc Furnaces (EAF) of Smaller and Larger Capacity. Part 2. Calculation and Analysis of the Relationship Between Position of Arcs, Walls and Power Consumption
The arc efficiency and specific power consumption were calculated and analyzed for the small (1.5 to 20 tons) and large (100 to 120 tons) capacity electric arc furnaces. In the small-capacity furnaces, the increased specific power consumption for melting the furnace charge (475 to 500 kW · h/t) is associated with low arc efficiency (0.55 to 0.57). In the large-capacity furnaces, the arc efficiency is 0.78 to 0.8 and specific power consumption is 360 to 375 kW · h/t.
Read moreAccounting of energy consumption of passenger electric locomotives in locomotive operational depots
Energy efficiency of transportation process is constantly in the center of attention of specialists and managers of Russian Railways. Some of the new electric locomotives purchased under the investment project have shown unsatisfactory results on electric power consumption. According to the management of the JSC “Russian Railways”, electric locomotives EP20, designed for two types of current, have the highest specific energy consumption. These are modern electric locomotives with powerful asynchronous traction motors. Electric locomotives typically operate in passenger traffic. The purpose of the research was to analyze the accounting of energy consumption of passenger electric locomotives in the locomotive operating depots. The article provides results of a comparative statistical analysis of primary materials on the energy consumption of passenger electric locomotives EP20 and other series of electric locomotives such as EP2K DC and EP1M AC. According to the primary materials from the locomotive operational depots, it was found that passenger electric locomotives with trains of double-decker passenger cars have the highest specific energy consumption. Comparison of specific electric power consumption by electric locomotives with single-type passenger cars showed that with DC electric traction, the consumption level of the EP20 significantly exceeds the consumption of the electric locomotives EP2K; with an AC electric traction, the flow rate of the EP20 is almost equal to the specific electric power consumption of the EP1M electric locomotives. A comparative analysis of the load of EP20 electric locomotives during the maintenance of passenger trains allocated for it in the Moscow — Adler section showed that the electric locomotive was underloaded, which causes a decrease in its efficiency and, as a result, over-consumption of electricity. The use of high-power brake resistors will lead to energy consumption, which must be taken into account in the life cycle cost of EP20 electric locomotives.
Read moreMulti objective optimization of the MED-TVC system with exergetic and heat transfer analysis
The mathematical model to predict the performance and the exergetic efficiency in a multi-effect desalination system with thermal vapor compression (MED-TVC system) has been presented. The energy and the concentration conservation law were developed for each effect, considering the boiling point elevation and the various thermodynamic losses by developing the mathematical models. These analyses led to the determination of the thermodynamic properties at different points and to the gain output ratio (GOR) values. Then, a heat transfer equation was developed in each effect and the required heat transfer areas were determined. Finally, irreversibility analysis was performed, from which the exergy destruction (considering chemical and physical exergy) and the exergetic efficiency were calculated. To obtain the optimum point of a system, multi-objective optimization was used. Determination of the best trade-off between GOR and heat transfer area was the final goal of this optimization. The optimum design led to a selected system with the lowest heat transfer area (and related cost) and the highest GOR.
Read moreOptimization of Low-Grade Solar Thermal Desalination Powerplant
An optimized design for a solar-powered desalination plant is proposed in this study, motivated by the increasing demand for freshwater. The main objective of this paper is to investigate the viability of a Mechanical Vapor Compression (MVC) desalination system powered by a Regenerative Organic Rankine Cycle utilizing a low-grade solar thermal energy system within 200°C –400°C. The success criteria of the desalination plant are based on the recovery ratio, flow rate, and specific power consumption. The test matrix includes feed concentrations of up to 35 ppt and boiler temperatures ranging from 200 °C to 400 °C, typical of Low-grade solar collectors. Comparative analysis of power output for different cycles has been presented, and the results indicate that for heat sources below 400°C, the application of regenerative ORC is recommended. The results show that the Regenerative Rankine cycle can achieve a thermal efficiency of up to 33%. The study examined both compression and vacuum modes of the MVC desalination plant. It was found that MVC could achieve lower specific power consumption (kWh/m3) when the cycle was operated under vacuum conditions.
Read moreThe Grain Cleaning Production Lines’ Energysaving Operation Modes of Electromechanical Systems
The research was aimed at reducing the power consumption for grain cleaning by using energy-saving modes in the electromechanical systems of grain cleaning units. Specific consumption of active energy per production unit was adopted as a criterion for assessing energy-saving operation modes. The applied method of mathematical experiment planning (MEP) reduced the number of experiments to a minimum to obtain a reliable mathematical model of the research object. To determine the optimal specific power consumption, a theoretical method was developed to rebuild the mathematical model. Thus, the minimum specific power consumption of grain cleaning production lines was obtained, which allowed developing science-based rates of power usage that allow energy savings up to 8-10%.
Read moreStudy of gas-liquid mass transfer in bubble and spray column adding solid media
Gas absorption is a separation process that transfers substances from gas phase to liquid phases due to the different concentrations. The operation can be applied in many treatments or purifying processes e.g. CO2 absorption from biogas or volatile organic compounds (VOCs) recovery from petroleum emission air. The conventional unit operation using for the gas absorption process are bubble column and spray column. Although there are several literatures reporting the efficiency of spray columns and bubble columns, those were done separately. Therefore, this research projected to investigate both hydrodynamics and mass transfer in both spray and bubble columns and comparing their specific power consumptions in order to develop the selection a guideline for industrial usages. The results indicated that the bubble column had larger specific interfacial area than the spray column when using at small gas loading rate. At this range of operation, the bubble column yielded higher overall mass transfer coefficient with the same specific power consumption. However, when operating at high gas loading rate, the spray column was the one better than the bubble column since the bubble column consumed larger power consumption as the pressure drop of the bubble column was mostly due to the gas flow.
 
 In addition, this research also studied the effect of solid phase on the hydrodynamics and mass transfer in the bubble column and spray column. By using the colorimetric method of red bottle experiment, it was found that the bubble-particles collision diminished the mass transfer of bubbles because the collision slowed down the bubbles especially for the small bubbles due to the fact that the small bubble simply lost their velocities from the collision. However, there was an advantage of introducing the particles since solid particles could obstruct the rising bubble and reduced its rising velocity. Consequently, the contact time between gas and liquid is increased and resulted in higher gas hold up and specific interfacial area. Therefore, with the appropriate conditions for which solid promoted specific interfacial area higher than diminished the mass transfer coefficient, the higher mass transfer rate was achieved. For the experimental setup using in this research, the enhance of mass transfer rate was occurred when the movable ring-shaped particles were introduced into the column that had large orifice sizes of gas sparger.
 
 In addition, this thesis also developed a colorimetric method to determine the overall mass transfer coefficient of oxygen without using other equipment rather than measuring the time which color of the solution changed from colorless to saturated red. This technique is very useful in the aspect of education since it does not require another equipment for measurement rather than visually observation. Nevertheless, the performance of optical fiber probes for hydrodynamics determination of droplets were also investigated.
Read moreInfluence of capacity, distance from arcs to walls on the efficiency of arcs and electricity consumption in arc steel-making furnaces
The influence of the distance from the arc to the walls in the entire range of arc steel-making furnaces with a capacity from 0.5 to 120 tons on the efficiency of arcs and specific power consumption in the furnaces was investigated. In low-tonnage arc steel-making furnaces, the arcs are close to the walls and the efficiency of the arcs is small and amounts to 30-35%, and the specific power consumption for melting is 650 kWh/t. In heavy-duty steel-arc furnaces, the arcs are located far from the walls, the efficiency of the arcs is 46-49% in the absence of a slag layer, and the specific energy consumption for melting is 375-385 kWh/t.
Read moreEnergy saving and production increase of mixed refrigerant natural gas liquefaction plants by taking advantage of natural cold sources in winter
Energy saving and production increase of mixed refrigerant natural gas liquefaction plants by taking advantage of natural cold sources in winter
Read moreDevelopment and performance test of a miniature movable mixed-refrigerant liquid nitrogen generator
Development and performance test of a miniature movable mixed-refrigerant liquid nitrogen generator