- Supplementary Content
- 10.1016/s0097-5990(16)30562-0
Abstracts
- Nov 01, 1992
- QRB - Quality Review Bulletin
Abstracts
The effective design and control of a capillary electrophoresis (CE) microchip requires a thorough understanding of the electrokinetic transport phenomena associated with its microfluidic injection system. The present study utilizes a numerical simulation approach to investigate these electrokinetic transport processes and to study the control parameters of the injection process. Injection systems with a variety of different configurations are designed and tested, including the cross-form, T-form, double-T-form, variable-volume focused flow cross-form, and variable-volume triple-T-form configuration. Each injection system cycles through a predetermined series of steps in which the magnitudes and distributions of the applied electric field are precisely manipulated in order to effectuate a virtual valve. This study investigates the sample leakage effect associated with each of the injection configurations and applies the double-L, pullback, and focusing injection techniques to minimize the sample leakage effect. The injection methods presented in this paper have the exciting potential for use in high-quality, high-throughput chemical analysis applications and throughout the micro-total-analysis systems field.
Abstracts
Abstracts
Procedure 48 Separation and amperometric detection of hydrogen peroxide and l-ascorbic acid using capillary electrophoresis microchips
Procedure 48 Separation and amperometric detection of hydrogen peroxide and l-ascorbic acid using capillary electrophoresis microchips
Read moreHigh-voltage capacitively coupled contactless conductivity detection for conventional and microchip capillary electrophoresis
This thesis focuses on the optimisation of capacitively coupled contactless conductivity detection for capillary and microchip electrophoresis and its applications in analytical chemistry. First, the effect of high excitation voltages and operation frequencies on the capacitively coupled contactless conductivity detector cell for conventional capillary electrophoresis is evaluated. The detector electrodes comprised two steel tubes cut from hypodermic needles, through which the capillaries were inserted. It is demonstrated that increasing excitation voltages from 25 V pp, to 250 Vpp improves the detection limits by a factor of 10. The high actuator voltage approach was also investigated for contactless conductivity detection on a glass-microchip device with ancm long channel. The detector electrodes formed part of the microchip and were placed on the microchip directly above the microchannel. In a separate project the simplification of on-microchip contactless conductivity detection was accomplished. This was achieved by integrating the detector electrodes on to a chip-holder specifically designed for this purpose. Thus the electrodes were a part of the holder, an improvement of the previous arrangement whereby the detector electrodes were situated on the microdevice. Finally the applications and advantages of the optimised high-voltage capacitively coupled contactless conductivity detection for inorganic and organic analysis were demonstrated. The separation and detection of 14 metal ions was accomplished in less than six minutes. The compatibility of this detector with non-UV transparent, polymer capillaries has been demonstrated. The detection of native amino acids has been evaluated. Part of the work was dedicated to the on-chip analysis of various classes of organic ions. The two immunoproteins human immunoglobulin M (IgM) and immunoglobulin G (IgG), were analysed in their unlabelled state on both capillary and lab-on-chip platforms. All species involved in an immunological interaction between IgM and IgG could be detected. A method for the analysis of selected basic pharmaceutical drug substances was developed. Detection limits comparable to those supplied by direct UV detection were obtained. Main component assays of selected pharmaceutical preparations have been demonstrated.
Read moreDirect measurement of lithium in whole blood using microchip capillary electrophoresis with integrated conductivity detection.
The direct measurement of lithium in whole blood is described. Using microchip capillary electrophoresis (CE) with defined sample loading and applying the principles of column coupling, alkali metals were determined in a drop of whole blood. Blood collected from a finger stick was mixed with anticoagulant and transferred onto the chip without extraction or removal of components. The electrokinetic transport of red blood cells inside the channels was studied to find sample loading conditions suitable for the analysis of lithium without injecting cells into the separation channel. Both bare glass chips and chips coated with polyacrylamide were used showing the behavior of the cells under different electroosmotic flow conditions. In serum a detection limit for lithium of 0.4 mmol/L was reached. Proteins quickly contaminated untreated chip surfaces but devices with coating gave reproducible electropherograms. In addition, potassium and sodium were also detected in the same separation run. To our knowledge, this is the first device to directly measure ions in whole blood with the use of capillary zone electrophoresis on a microchip.
Read moreExperimental and Numerical Analysis of High-Resolution Injection Technique for Capillary Electrophoresis Microchip
This study presents an experimental and numerical investigation on the use of high-resolution injection techniques to deliver sample plugs within a capillary electrophoresis (CE) microchip. The CE microfluidic device was integrated into a U-shaped injection system and an expansion chamber located at the inlet of the separation channel, which can miniize the sample leakage effect and deliver a high-quality sample plug into the separation channel so that the detection performance of the device is enhanced. The proposed 45° U-shaped injection system was investigated using a sample of Rhodamine B dye. Meanwhile, the analysis of the current CE microfluidic chip was studied by considering the separation of Hae III digested ϕx-174 DNA samples. The experimental and numerical results indicate that the included 45° U-shaped injector completely eliminates the sample leakage and an expansion separation channel with an expansion ratio of 2.5 delivers a sample plug with a perfect detection shape and highest concentration intensity, hence enabling an optimal injection and separation performance.
Read moreMeasuring Electroosmotic Flow in Microchips and Capillaries
Electrophoretic migration and electroosmotic flow (EOF) combine to determine the migration rate of charged compounds in capillary electrophoresis (CE) and microchip capillary electrophoresis (MCE). Uncontrolled and unmeasured changes in EOF will lead to irreproducible peak migration times and poor peak quantitation. The two most common methods for measuring EOF for CE and MCE are detailed. Experimental results for application of the neutral marker method and the current monitoring method to EC are presented, and related calculations of EOF rates and electroosmotic mobility are described. The strengths and shortcomings of these two EOF measurement techniques are discussed. Additional approaches for studying and measuring EOF and for improving the reproducibility of migration times for CE and MCE are summarized.
Read moreNumerical analysis of an electrokinetic double‐focusing injection technique for microchip CE
The injection techniques in electrophoresis microchips play an important role in the sample-handling process, whose characteristics determine the separation performance achieved, and the shape of a sample plug delivered into the separation channel has a great impact on the high-quality separation performance as well. This paper describes a numerical investigation of different electrokinetic injection techniques to deliver a sample plug within electrophoresis microchips. A novel double-focusing injection system is designed and fabricated, which involves four accessory arm channels in which symmetrical focusing potentials are loaded to form a unique parallel electric field distribution in the intersection of injection channel and separation channel. The parallel electric field effectuates virtual walls to confine the spreading of a sample plug at the intersection and prevents sample leakage into separation channel during the dispensing step. The key features of this technique over other injection techniques are the abilities to generate regular and nondistorted shape of sample plugs and deliver the variable-volume sample plugs by electrokinetic focusing. The detection peak in the proposed injection system is uniform regardless of the position of the detection probe in the separation channel, and the peak resolution is greatly enhanced. Finally, the double-focusing injection technique shows the flexibility in detection position and ensures improved signal sensitivity with good peak resolution due to the delivered high-quality sample plug.
Read moreRecent capillary electrophoresis applications for upstream and downstream biopharmaceutical process monitoring
The biopharmaceutical market is one of the fastest growing biotechnology markets. In order to ensure affordable and reliable therapeutics, the biopharmaceutical process has to be closely monitored. Capillary electrophoresis (CE) has proven to be a valuable technique for the analysis of product concentration, critical quality attributes, product and process-related impurities, and nutrients and metabolites in the cell culture medium. Capillary zone electrophoresis, capillary gel electrophoresis, and capillary isoelectric focusing are extensively used for product concentration, and size or charge heterogeneity determination. CE has a number of benefits for the analysis of upstream and downstream process-intermediates, including the ability to handle highly complex matrices found in process-intermediates, high resolving power, little sample preparation requirements, rapid analysis, and low solvent and sample consumption. The small sample volumes (nL range) are especially beneficial for microbioreactor analysis or clone selection experiments. The simple setup and the possibility for miniaturisation and automation using microchip CE provides great opportunities for on-site, real-time monitoring of the process. This review discusses CE applications in upstream and downstream processing of the last decade.
Read moreNative fluorescence detection of flavin derivatives by microchip capillary electrophoresis with laser-induced fluorescence intensified charge-coupled device detection
Native fluorescence detection of flavin derivatives by microchip capillary electrophoresis with laser-induced fluorescence intensified charge-coupled device detection
Read moreHigh‐voltage power supplies to capillary and microchip electrophoresis
Over the past years, the development of capillary electrophoresis (CE) and microchip electrophoresis (ME) systems has grown due to instrumental simplicity and wide application. In both CE and ME, the application of a high voltage (HV) is a crucial step in the electrokinetic (EK) injection and separation processes. Particularly on ME devices, EK injection is often performed with three different modes: gated, pinched, and unpinched. In all these cases, different potential values may be applied to one or multiple channels to control the injection of small sample volumes as well as the separation process. For this reason, the construction of reliable HV power supplies (HVPS) is required. This review covers the advances of the development of commercial and laboratory-built HVPS for CE and ME. Moreover, it intends to be a guide for new developers of electrophoresis instrumentation.
Read moreMicrochip capillary electrophoresis-mass spectrometry for high-throughput simultaneous analysis of B-complex vitamins.
Microchip capillary electrophoresis-mass spectrometry for high-throughput simultaneous analysis of B-complex vitamins.
Microchip capillary electrophoresis with laser-induced fluorescence combined with one-step duplex reverse-transcription polymerase chain reaction for the rapid detection of Enterovirus 71 and Coxsackievirus A16 in throat swab specimens.
Enterovirus 71 and Coxsackievirus A16 are the main pathogens causing hand-foot-mouth disease. In this paper, microchip capillary electrophoresis with laser-induced fluorescence combined with one-step duplex reverse transcript-polymerase chain reaction has been developed for the detection of Enterovirus 71 and Coxsackievirus A16 in throat swab specimens. The specific reverse transcription-polymerase chain reaction amplicons labeled with SYBR Orange were separated by microchip capillary electrophoresis and detected by laser induced fluorescence detector within 7 min. The intraday and interday relative standard deviation of migration time for DNA Marker was in the range of 1.36-2.94 and 2.78-3.96%, respectively. The detection limits were as low as 2.06 × 10(3) copies/mL for Enterovirus 71 and 5 × 10(3) copies/mL for Coxsackievirus A16. No cross-reactivity was observed with rotavirus, astrovirus, norovirus, and adenovirus, which showed good specificity of the method. This assay was validated using 100 throat swab specimens that were detected by real-time reverse-transcript polymerase chain reaction in parallel and the two methods produced the same results. This study provided a rapid, sensitive and specific method for the detection of Enterovirus 71 and Coxsackievirus A16, which make a contribution to significant time and cost saving for the identification and treatment of patients.
Read moreDetermination of neurotransmitters in PC 12 cells by microchip electrophoresis with fluorescence detection
A sensitive fluorescence detection system with an Hg-lamp as the excitation source and a photon counter as the detector for microchip CE (MCE) has been developed. O-Phthaldialdehyde (OPA, lambda(ex) = 340 nm) was employed to label the catecholamine neurotransmitters such as dopamine (DA), norepinephrine (NE), and amino acid neurotransmitters including alanine (Ala), taurine (Tau), glycine (Gly), glutamic acid (Glu), and aspartic acid (Asp). The separation of seven derivatized neurotransmitters was successfully performed in MCE and the detection limits (S/N = 3) for DA, NE, Ala, Tau, Gly, Glu, and Asp were 0.85, 0.49, 0.23, 0.15, 0.13, 0.18, and 0.29 fmol, respectively. The system was then successfully applied for separation and determination of neurotransmitters in rat pheochromocytoma (PC 12) cells, and the average amounts of analyte per cell from a cell population were 2.5 fmol for DA, 3.3 fmol for Ala, 8.2 fmol for Tau, 4.0 fmol for Gly, and 1.9 fmol for Glu, respectively. By single-cell injection mode, electrophoresis separation and quantitative measurement of Glu in individual PC 12 cells was obtained. The average value of Glu per cell from single PC 12 cells analysis was found to be 3.5 +/- 3.1 fmol.
Read moreCapillary electrophoresis microchip detecting system based on embedded optical fiber
<sup></sup>Microchip capillary electrophoresis(CE) has been recognized as a powerful tool for biochemical analyses due to its smaller size, faster separation and lower sample requirement. According to the principle of laser-induced fluorescence, the detecting system of CE microchip embedded optical fiber is discussed in this paper as well as its small volume and simple detection optical circuit. The system was composed with semiconductor laser (532nm), high voltage control system, photon counter, PC and CE chip embedded optical fibers. With the constructed detection system, different samples and different concentrations were detected, including Rhodamine B, Rhodamine 6G, and mingling solution of Rhodamine B and Rhodamine 6G. The lowest detected concentration is 1×10<sup>-6</sup>mol/L for Rhodamine B, and 1×10<sup>-5</sup>mol/L for Rhodamine 6G, respectively. The separation of the mingling solution of Rhodamine B and Rhodamine 6G was completed, whose concentration were both about 1×10<sup>-4</sup>mol/L. The results show that the constructed detection system possesses some advantages, such as compact structure, higher sensitivity and repetition, which are beneficial to the development of microminiaturization and integration of micro CE chip.
Read moreExperimental Investigation of High-Resolution Injection Technique in Microfluidic Chips
This paper presents an experimental investigation on the use of high-resolution injection techniques to deliver sample plugs within electrophoresis microchips. Two novel injection microfluidic chips are proposed, which employ conventional cross-shaped and U-shaped injection system combined with an expander to deliver high-quality sample plugs for detection in separation channel. The valving characteristics on microfluidic devices are controlled through appropriate manipulations of the electric potential strengths during the sample injection and separation steps. These novel injection techniques developed in this study has an exciting potential for use in high-quality, high-throughput chemical analysis applications and in many other applications throughout the field of micro-total-analysis systems.
Read more