• Home
  • Search
  • Optimization-based adaptive optics for optical coherence tomography
  • https://doi.org/10.4233/uuid:f6059ab2-adb2-4647-81be-09847fa9bd9fCopy DOI Icon

Optimization-based adaptive optics for optical coherence tomography

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

Optical coherence tomography (OCT) is a technique for non-invasive imaging based on low coherence interferometry. Its main application is found in ophthalmology, where it is used for 3D in vivo imaging of the cornea and the retina. OCT has evolved over the past decade as one of the most important ancillary tests in ophthalmic practice, providing great diagnostic value for disease screening and monitoring. In retinal OCT imaging, the lateral resolution is not determined by the pupil size, but instead it is limited by optical wavefront aberrations of the cornea and lens. These aberrations reduce the OCT image resolution and lower the signal to noise ratio. To obtain high quality OCT images the optical aberrations can be removed using adaptive optics (AO).<br/><br/>In general, AO consists of an adaptive optical element and a wavefront sensor. The adaptive element, such as a deformable mirror, is used to reshape the wavefront and remove the undesired aberrations. The wavefront sensor measures the aberrations by reconstructing the phase of the wavefront, which is used to determine the correction on the wavefront applied by the deformable mirror. However, the use of a wavefront sensor has some disadvantages. It requires light being directed out of the imaging path onto the wavefront sensor. This leads to a loss of signal in the imaging path and can result in non-common optical path errors in the aberrations estimation procedure. Additionally, the use of a deformable mirror and a wavefront sensor leads to a bulky and expensive OCT setup.<br/><br/>The work presented in this thesis has the goal of reducing the cost and bulkiness of an AO-OCT system. First, we investigate the influence of optical wavefront aberrations to the OCT signal strength. The establishment of the relation between aberrations and the OCT signal strength is key to estimating and correcting the aberrations based on single OCT scans. By using Fresnel optical wave propagation and determining the fiber coupling efficiency, we find that the OCT transfer function, i.e. the function that expresses the relation between the aberrations and OCT signal strength, is quasi-convex. We determine both analytically and experimentally the transfer function for both reflective and scattering media, such as a mirror and Scotch tape sample. Additionally, if the OCT system and its optical properties are well-known we demonstrate a method to correct a defocus aberration in one step. <br/><br/>Second, we use the OCT transfer function to develop and determine an efficient wavefront sensorless (WFSL) AO optimization procedure. WFSL-AO methods aim to correct the aberrations without using a wavefront sensor, but instead base the determination of the wavefront on the imaging signal itself. This eliminates the use of the wavefront sensor, its extra cost and its disadvantages from an AO-OCT setup. To keep up with the OCT imaging rate, which is of the order of several tens of kHz, the algorithm has to be computationally efficient. Furthermore, there are no analytic derivatives available for the optimization and the OCT signal is very noisy. Finally, the derivative-free optimization algorithm also has to be able to determine the aberrations accurately when dealing with a minimum number of noisy measurements. We developed the Data-based Online Nonlinear extremum-seeker (DONE) algorithm. Every iteration, the DONE algorithm updates a surrogate function, which is based on random Fourier expansions (RFE) of the OCT transfer function, with a new OCT signal measurement. The optimum of the RFE surrogate function is then found with a well-known (quasi-Newton) optimization method. We demonstrate the effectiveness of the DONE algorithm compared to other optimization algorithms for WFSL-AO on biological and non-biological samples. We conclude that DONE has a smaller convergence error, while maintaining similar or faster convergence speeds compared to the other algorithms. <br/><br/>Third, we demonstrate a fully functional WFSL-AO OCT setup for retinal imaging. We use a state-of-the-art deformable lens with 18 actuators, rather than a deformable mirror, which leads to a smaller and more integrated WFSL-AO setup. The WFSL-AO OCT setup is successfully used for in vivo retinal OCT imaging and demonstrates that the DONE algorithm can remove the ocular wavefront aberrations with the deformable lens during in vivo OCT imaging. By developing a new algorithm and exploring the options for adaptive components, we have succeeded in retinal WFSL-AO OCT.<br/><br/>In a broader perspective, we show that the DONE algorithm is suitable for other applications than WFSL-AO OCT. We demonstrate that the DONE derivative-free optimization algorithm is robust towards noisy measurements for applications in robotics, microscopy and optical beam forming networks.

Similar Papers
  • PDF
  • Research Article
  • Citations4

The Role of Optical Coherence Tomography Signal Strength in the Diagnosis and Follow-up of Patients with Posterior Capsular Opacification Treated with Nd:YAG Laser Capsulotomy

  • Jan 01, 2020
  • Turkish Journal of Ophthalmology
  • Mustafa Vatansever +5
  • Research Article
  • Citations2

Linear multifractional stable motion for modeling of fluid-filled regions in retinal optical coherence tomography images

  • Jan 24, 2024
  • Chaos, Solitons & Fractals
  • Mahnoosh Tajmirriahi +1
  • PDF
  • Research Article
  • Citations6

Birefringence-derived scleral artifacts in optical coherence tomography images of eyes with pathologic myopia

  • Nov 16, 2022
  • Scientific Reports
  • Masahiro Miura +8
  • Research Article
  • Citations125

Signal Quality Assessment of Retinal Optical Coherence Tomography Images

  • Apr 24, 2012
  • Investigative Opthalmology & Visual Science
  • Yijun Huang +7
  • Research Article
  • Citations236

Attention to Lesion: Lesion-Aware Convolutional Neural Network for Retinal Optical Coherence Tomography Image Classification.

  • Feb 08, 2019
  • IEEE Transactions on Medical Imaging
  • Leyuan Fang +5
  • Research Article
  • Citations4

A Device-Independent, Shape Preserving Retinal Optical Coherence Tomography Image Alignment Method Applying TV-Unet for RPE Layer Detection

  • Jan 01, 2022
  • IEEE Transactions on Instrumentation and Measurement
  • Narges Saeedizadeh +8
  • Research Article
  • Citations25

Automatic classification of retinal three-dimensional optical coherence tomography images using principal component analysis network with composite kernels.

  • Nov 29, 2017
  • Journal of Biomedical Optics
  • Leyuan Fang +1
  • Research Article
  • Citations313

Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects.

  • Dec 01, 2002
  • Diabetes Care
  • Kirill V Larin +3
  • Research Article
  • Citations49

Optical Coherence Tomography

  • Oct 22, 2012
  • Circulation
  • James M Mccabe +1
  • Conference Article
  • Citations27

Quality Improvement of Retinal Optical Coherence Tomography

  • May 21, 2021
  • A Rajani +3
  • Research Article

Macrophage content detection in an experimental rabbit model of atherosclerotic plaque by optical coherence tomography

  • Feb 01, 2015
  • Chinese journal of cardiovascular diseases
  • Xiying Yu +4
  • Research Article
  • Citations20

Automatic Classification of Volumetric Optical Coherence Tomography Images via Recurrent Neural Network

  • Jul 06, 2020
  • Sensing and Imaging
  • Chong Wang +3
  • Conference Article
  • Citations2

Layer Structures Localization in Optical Coherence Tomography Images

  • Oct 01, 2006
  • 2006 International Symposium on Biophotonics, Nanophotonics and Metamaterials
  • Yi Zhu +5
  • Research Article
  • Citations13

Deep Learning–Based Clustering of OCT Images for Biomarker Discovery in Age-Related Macular Degeneration (PINNACLE Study Report 4)

  • May 31, 2024
  • Ophthalmology Science
  • Robbie Holland +11
  • Book Chapter

Detection of DME in OCT Images Based on Histogram Descriptor

  • Jan 01, 2022
  • Puspita Dash +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.