• Home
  • Search
  • Optimization of implantable collamer lens sizing based on swept-source anterior segment optical coherence tomography.
  • Cite Icon92
  • https://doi.org/10.1097/j.jcrs.0000000000000134Copy DOI Icon

Optimization of implantable collamer lens sizing based on swept-source anterior segment optical coherence tomography.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

To optimize the implantable collamer lens (ICL) sizing method using anterior segment optical coherence tomography (AS-OCT). Nagoya Eye Clinic, Nagoya, Japan. Interventional case series. A stepwise multiple regression analysis was performed using the optimal ICL size as a dependent variable and preoperative AS-OCT parameters as explanatory variables for 81 eyes of 41 patients, and the NK-formula version 2 (NK-formula V2) was obtained. Thereafter, 68 eyes of 42 patients were implanted with the ICLs selected as closest to the optimal ICL size calculated by the NK-formula V2. At 3 months postoperatively, the achieved vault was measured by AS-OCT to evaluate the optimization of the sizing method. The anterior chamber width (ACW) and crystalline lens rise were selected as significant parameters for the regression model (R = 0.61, P < .001), as with the previous NK-formula. Of the 68 eyes, 36 patients/62 eyes (91.2%), 5 patients/5 eyes (7.3%), and 1 patient/1 eye (1.5%) were in the moderate, high, and low vault categories, respectively. In the 68 eyes, the vault showed no correlation with the optimal ICL size (R = 0.0185, P = .269), whereas the vault showed a negative correlation with the optimal ICL size in both the 12.6 mm ICL subgroup (R = -0.409, P = .0088) and the 13.2 mm ICL subgroup (R = -0.818, P = .0013). This optimization approach showed excellent ability to select an appropriate ICL to be implanted regardless of the value of other ocular parameters and age, except ACW.

Similar Papers
  • PDF
  • Research Article
  • Citations21

Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula.

  • Apr 27, 2023
  • Frontiers in Medicine
  • Hao Wu +5
  • Research Article

Implantable collamer lens sizing optimization based on the anterion AS-OCT biometric parameters.

  • Mar 10, 2025
  • Eye (London, England)
  • Ramin Salouti +6
  • Research Article

Direct measurement of the ciliary sulcus diameter using optical coherence tomography: Inter‐rater variability

  • Jan 01, 2024
  • Acta Ophthalmologica
  • Timo Eppig +7
  • Research Article
  • Citations1

Anterior segment optical coherence tomography in black‐on‐clear polypseudophakia

  • Feb 25, 2013
  • Acta Ophthalmologica
  • Imran H Yusuf +2
  • Research Article
  • Citations3

The Distribution of Crystalline Lens Rise in High Myopia Population and Its Influence on Vault After Implanting Intraocular Collamer Lens.

  • Feb 06, 2024
  • Ophthalmology and therapy
  • Ziyu Zhou +6
  • Research Article
  • Citations1

Detection of the anterior segment biological parameters of primary angle closure glaucoma and the normal eyes by optical coherence tomography

  • Feb 10, 2019
  • Chinese Journal of Experimental Ophthalmology
  • Songbo Pei +4
  • Research Article
  • Citations1

A quantitative assessment of the vault optimization along with the ocular bio-parameters and Implantable Collamer Lens sizing nomograms.

  • Jun 04, 2025
  • Journal of cataract and refractive surgery
  • Lan Bifei +5
  • Research Article
  • Citations51

Repeatability and reproducibility of anterior ocular biometric measurements with 2-dimensional and 3-dimensional optical coherence tomography

  • Oct 26, 2010
  • Journal of Cataract and Refractive Surgery
  • Shinichi Fukuda +3
  • Research Article
  • Citations16

Swept-source anterior segment optical coherence tomography in late-onset capsular block syndrome: High-resolution imaging and morphometric modifications after posterior capsulotomy

  • Sep 07, 2013
  • Journal of Cataract and Refractive Surgery
  • Alberto Neri +5
  • Research Article
  • Citations5

Direct Measurement of the Ciliary Sulcus Diameter Using Optical Coherence Tomography-Inter-Rater Variability.

  • Oct 29, 2024
  • Sensors (Basel, Switzerland)
  • Timo Eppig +7
  • Research Article

Quantitative in vivo assessment of intraocular lens calcification: correlation between OCT opacity and straylight measurement.

  • Apr 17, 2025
  • Journal of cataract and refractive surgery
  • Lars H B Mackenbrock +5
  • Research Article
  • Citations8

Anterior segment OCT application in quantifying posterior capsule opacification severity with varied intraocular lens designs.

  • Sep 18, 2021
  • International Journal of Ophthalmology
  • Sha-Sha Yu +3
  • Research Article
  • Citations15

Anterior segment optical coherence tomography of intraocular lens opacification

  • Jun 01, 2018
  • Indian Journal of Ophthalmology
  • Neha Goel +3
  • Research Article
  • Citations22

Tomography-Based Customized IOL Calculation Model

  • May 18, 2011
  • Current Eye Research
  • Zhongxia Zhu +4
  • Research Article
  • Citations1

Establishment of a new vault prediction formula after implantable collamer lens implantation based on factor analysis of multi-modal ophthalmic parameters of anterior and posterior chamber.

  • Aug 09, 2024
  • Clinical & experimental ophthalmology
  • Yijia Xu +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.