• Home
  • Search
  • Tomography-Based Customized IOL Calculation Model
  • Cite Icon22
  • https://doi.org/10.3109/02713683.2011.566978Copy DOI Icon

Tomography-Based Customized IOL Calculation Model

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Purpose: To provide a mathematical calculation scheme for customized intraocular lens (IOL) design based on high resolution anterior segment optical coherence tomography (AS-OCT) of anterior eye segment and axial length data.Material and Methods: We use the corneal and anterior segment data from the high resolution AS-OCT and the axial length data from the IOLMaster to create a pseudophakic eye model. An inverse calculation algorithm for the IOL back surface optimization is introduced. We employ free form surface representation (bi-cubic spline) for the corneal and IOL surface. The merit of this strategy is demonstrated by comparing with a standard spherical model and quadratic function. Four models are calculated: (1) quadratic cornea + quadratic IOL; (2) spline cornea + quadratic IOL; (3) spline cornea + spline IOL; and (4) spherical cornea + spherical IOL. The IOL optimization process for the pseudophakic eye is performed by numerical ray-tracing method within a 6-mm zone. The spot diagram on the fovea (forward ray-tracing) and wavefront at the spectacle plane (backward ray-tracing) are compared for different models respectively.Results: The models with quadratic (1) or spline (3) surface representation showed superior image performance than the spherical model 4. The residual wavefront errors (peak to valley) of models 1, 2, and 3 are below one micron scale. Model 4 showed max wavefront error of about 15 µm peak to valley. However, the combination of quadratic best fit IOL with the free form cornea (model 2) showed one magnitude smaller wavefront error than the spherical representation of both surfaces (model 3). This results from higher order terms in cornea height profile.Conclusions: A four-surface eye model using a numerical ray-tracing method is proposed for customized IOL calculation. High resolution OCT data can be used as a sufficient base for a customized IOL characterization.

Similar Papers
  • Research Article
  • Citations12

Ocular wavefront analysis and contrast sensitivity in eyes implanted with AcrySof IQ or AcrySof Natural intraocular lenses

  • Oct 20, 2009
  • Acta Ophthalmologica
  • Tamer Takmaz +3
  • Research Article
  • Citations1

Anterior segment optical coherence tomography in black‐on‐clear polypseudophakia

  • Feb 25, 2013
  • Acta Ophthalmologica
  • Imran H Yusuf +2
  • Research Article
  • Citations30

Customized aspheric intraocular lenses calculated with real ray tracing

  • Oct 28, 2009
  • Journal of Cataract and Refractive Surgery
  • Jens Einighammer +4
  • Research Article
  • Citations208

Optical Quality and Depth-of-field of Eyes Implanted With Spherical and Aspheric Intraocular Lenses

  • May 01, 2005
  • Journal of Refractive Surgery
  • Susana Marcos +2
  • Research Article
  • Citations16

Swept-source anterior segment optical coherence tomography in late-onset capsular block syndrome: High-resolution imaging and morphometric modifications after posterior capsulotomy

  • Sep 07, 2013
  • Journal of Cataract and Refractive Surgery
  • Alberto Neri +5
  • Research Article
  • Citations16

Optical Quality Comparison between Spherical and Aspheric Toric Intraocular Lenses

  • Sep 01, 2014
  • European Journal of Ophthalmology
  • Cari Pérez-Vives +4
  • Research Article

Optical performance of rotation and decentration of Toric intraocular lens implant in Hwey-Lan Liou model eye

  • Nov 10, 2017
  • Chinese Journal of Experimental Ophthalmology
  • Qiannan Chai +6
  • Research Article
  • Citations8

Anterior segment OCT application in quantifying posterior capsule opacification severity with varied intraocular lens designs.

  • Sep 18, 2021
  • International Journal of Ophthalmology
  • Sha-Sha Yu +3
  • Research Article
  • Citations8

Fellow-eye comparison of 2 aspheric microincision intraocular lenses and effect of asphericity on visual performance

  • Feb 18, 2012
  • Journal of Cataract and Refractive Surgery
  • Mayank A Nanavaty +2
  • Conference Article

Development of fibrin-free intraocular lens with photochemical surface modification

  • Jul 13, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yuji Sato +7
  • Research Article
  • Citations22

Occlusion of AquaPORT Flow in a Case of Toxic Anterior Segment Syndrome Following Implantable Collamer Lens Surgery Causing Severe Pupillary Block.

  • Dec 01, 2020
  • Journal of Refractive Surgery
  • Michael Mimouni +2
  • Research Article
  • Citations5

Comparison of Optical Performances in Eyes Implanted With Aspheric and Spherical Intraocular Lenses After Cataract Surgery

  • Jan 01, 2010
  • Journal of the Korean Ophthalmological Society
  • Jin Ho Jeong +3
  • Research Article
  • Citations18

Anterior Segment Optical Coherence Tomography Findings of Acute Hydrops in a Patient with Keratoconus

  • Mar 09, 2010
  • Ophthalmic Surgery, Lasers and Imaging Retina
  • Beril R Kucumen +3
  • Research Article

The Optical Performance Parameters for Rotation and Decentration of the Aspherical Biconvex Toric Intraocular Lens

  • Jan 25, 2018
  • Chinese Journal of Optometry & Ophthalmology
  • Bin Zhang +6
  • Research Article
  • Citations92

Optimization of implantable collamer lens sizing based on swept-source anterior segment optical coherence tomography.

  • May 01, 2020
  • Journal of Cataract and Refractive Surgery
  • Tomoaki Nakamura +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.