Performance Evaluation Of A New Dedicated Mammography System

  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

The performance characteristics of a new dedicated mammography unit (a Mammo Diagnost U-M, Philips Medical Systems, Inc., Shelton, Conn.) are presented. The unit has capabilities for contact imaging with or without a grid and magnification imaging without a grid, using a molybdenum target and either of two different beam filtrations (molybdenum or aluminum). Characteristics evaluated include the performance of the beam restriction system, accuracy of technique parameter selector indication of kilovoltage, tube current and exposure time, focal spot size, exposure output and beam quality characteristics as a function of kilovoltage and filtration, compression device attenuation and automatic exposure control system performance. The resultant data have been used to calculate breast entrance exposure and average glandular dose for each imaging modality and to compare the different imaging modalities in terms of equivalent bandwidth, fe, using established models for the modulation transfer functions of the focal spot and image receptor. Modifications to the system to enhance clinical utility and to allow for routine calculations of patient exposure are also described.

Similar Papers
  • Research Article
  • Citations2

An alignment test jig for measuring the effective focal-spot size of mammographic X-ray tubes

  • May 01, 1989
  • The British Journal of Radiology
  • M L Ramsdale +2
  • Research Article
  • Citations66

Generation and analysis of clinically relevant breast imaging x-ray spectra

  • May 04, 2017
  • Medical physics
  • Andrew M Hernandez +3
  • Research Article
  • Citations6

A comparison of US- versus MR-based 3-D Prostate Shapes Using Radial Basis Function Interpolation and Statistical Shape Models.

  • May 19, 2014
  • IEEE journal of biomedical and health informatics
  • Ran Tao +3
  • Research Article
  • Citations18

Establishment of Microbeam Radiation Therapy at a Small-Animal Irradiator

  • Oct 07, 2020
  • International Journal of Radiation Oncology*Biology*Physics
  • Franziska Treibel +7
  • Research Article
  • Citations30

Method for measuring the focal spot size of an x‐ray tube using a coded aperture mask and a digital detector

  • Mar 23, 2011
  • Medical Physics
  • Paolo Russo +1
  • PDF
  • Research Article
  • Citations5

Single-pulse characterization of the focal spot size of X-ray free-electron lasers using coherent diffraction imaging

  • Mar 22, 2023
  • Journal of Synchrotron Radiation
  • Zichen Gao +12
  • Research Article
  • Citations34

Observations on magnification radiography. Visualization of small blood vessels and determination of focal spot size.

  • Mar 01, 1969
  • Radiology
  • Paul J Friedman +1
  • Research Article
  • Citations2

Line focal X-ray source imaging

  • Jan 01, 2016
  • Acta Physica Sinica
  • Liu Xin +2
  • Research Article
  • Citations5

A Monte Carlo study of the influence of focal spot size, intensity distribution, breast thickness and magnification on spatial resolution of an a-Se digital mammography system using the generalized MTF

  • Sep 05, 2013
  • Physica Medica
  • T Sakellaris +3
  • Research Article
  • Citations27

The effect of x‐ray beam quality and geometry on radiation utilization efficiency in multidetector CT imaging

  • Mar 20, 2009
  • Medical Physics
  • Kostas Perisinakis +2
  • Conference Article

Novel beam analysis applications and hardware

  • Jan 01, 2009
  • Thomas R Kugler
  • Research Article
  • Citations2

On the origin of MTF reduction in grating-based x-ray differential phase contrast CT imaging.

  • Dec 20, 2024
  • Medical physics
  • Yuhang Tan +5
  • Research Article
  • Citations14

Slit camera focal spot measurement errors in mammography

  • Nov 01, 1995
  • Medical Physics
  • S Tang +2
  • Research Article
  • Citations29

High power, high uniformity strip electron gun design, simulation and performance

  • Jan 01, 2001
  • Review of Scientific Instruments
  • K B Thakur +3
  • Research Article
  • Citations13

Radiographic detail and variation of the nominal focal spot size: the "focal effect".

  • Jul 01, 1992
  • Radiographics : a review publication of the Radiological Society of North America, Inc
  • M C Katz +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.