• Home
  • Search
  • Physics-informed model-based generative neural network for synthesizing scanner- and algorithm-specific low-dose CT exams.
  • https://doi.org/10.1002/mp.17680Copy DOI Icon

Physics-informed model-based generative neural network for synthesizing scanner- and algorithm-specific low-dose CT exams.

Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

Accurate low-dose CT simulation is required to efficiently assess reconstruction and dose reduction techniques. Projection domain noise insertion requires proprietary information from manufacturers. Analytic image domain noise insertion methods are successful for linear reconstruction algorithms, however extending them to non-linear algorithms remains challenging. Emerging, deep-learning-based image domain noise insertion methods have potential, but few approaches have explicitly incorporated physics information and a texture-synthesis model to guide the generation of locally and globally correlated noise texture. We proposed a physics-informed model-based generative neural network for simulating scanner- and algorithm-specific low-dose CT exams (PALETTE). It is expected to provide an alternative to projection domain noise insertion methods in the absence of manufacturers' proprietary information and tools. PALETTE integrated a physics-based noise prior generation process, a Noise2Noisier sub-network, and a noise texture synthesis sub-network. The Noise2Noisier sub-network provided a bias prior, which, combined with the noise prior, served as the inputs to noise texture synthesis sub-network. Explicit regularizations in spatial and frequency domains were developed to account for noise spatial correlation and frequency characteristics. For proof-of-concept, PALETTE was trained and validated for a commercial iterative reconstruction algorithm (SAFIRE, Siemens Healthineers), using the paired routine and 25% dose images from CT phantoms (lateral size 30-40 cm; three training and four testing phantoms) and open-access patient cases (10 training and 20 testing cases). In phantom validation, noise power spectra (NPS) were compared in water background and tissue-mimicking inserts, using peak frequency and mean-absolute-error (MAE). In patient case evaluation, visual inspection and quantitative assessment were conducted on axial, coronal, and sagittal planes. Local and global noise texture were visually inspected in low-dose CT images and the difference images between routine and low dose. Noise levels in liver and fat were measured. Local and global 2D Fourier magnitude spectra of the difference images and the corresponding radial mean profiles were used to assess similarity in noise frequency components within tissues and entire field-of-view, using spectral correlation mapper (SCM) and spectral angle mapper (SAM). Several baseline neural network models (e.g., GAN) were included in the evaluation. Statistical significance was tested using a t-test for related samples. PALETTE-derived NPS showed accurate noise peak frequency (PALETTE/reference: water 1.40/1.40 lp/cm; inserts 1.7/1.7lp/cm) and small MAE (≤0.65 HU2cm2). PALETTE created anatomy-dependent noise texture, showing realistic local and global granularity and streaks. No statistically significant difference was observed in noise levels (p > 0.05). Noise range was comparable across 3D image volume (PALETTE / reference):liver - [18.0, 53.4] / [19.3, 50.0] HU; fat - [11.7, 42.4] / [12.1, 41.3] HU. Percent absolute difference of local noise was small (mean ± standard deviation): liver 4.1%±3.1%, fat 4.6%±3.1%. Noise frequency distribution was close to the reference (mean per case): SCM ≥ 0.92, SAM ≤ 0.22. Additionally, PALETTE outperformed all baseline models in visual inspection and quantitative comparison. PALETTE can provide high-quality image domain noise insertion for simulating accurate low-dose CT images created with a commercial non-linear reconstruction algorithm.

Similar Papers
  • Conference Article
  • Citations1

A method to generate patient CT noise for deep learning network training

  • Apr 01, 2024
  • Minah Han +1
  • Research Article
  • Citations4

Deep learning-based low-dose CT simulator for non-linear reconstruction methods.

  • Jun 06, 2024
  • Medical physics
  • Sjoerd A M Tunissen +5
  • Research Article
  • Citations1081

Generative Adversarial Networks for Noise Reduction in Low-Dose CT.

  • May 26, 2017
  • IEEE Transactions on Medical Imaging
  • Jelmer M Wolterink +3
  • Conference Article
  • Citations27

Automated coronary artery calcification detection on low-dose chest CT images

  • Mar 20, 2014
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yiting Xie +4
  • Research Article
  • Citations2

Weakly supervised low-dose computed tomography denoising based on generative adversarial networks.

  • Aug 01, 2024
  • Quantitative imaging in medicine and surgery
  • Peixi Liao +7
  • Research Article
  • Citations36

Low-Dose Lung CT Image Restoration Using Adaptive Prior Features From Full-Dose Training Database

  • Sep 27, 2017
  • IEEE Transactions on Medical Imaging
  • Yuanke Zhang +4
  • Research Article
  • Citations17

Assessment of prior image induced nonlocal means regularization for low-dose CT reconstruction: change in anatomy

  • Sep 01, 2017
  • Medical physics
  • Hao Zhang +4
  • PDF
  • Supplementary Content
  • Citations18

Low-Dose Chest CT Protocols for Imaging COVID-19 Pneumonia: Technique Parameters and Radiation Dose

  • Apr 12, 2023
  • Life
  • Ibrahim I Suliman +4
  • Research Article
  • Citations41

StatNet: Statistical Image Restoration for Low-Dose CT using Deep Learning

  • May 28, 2020
  • IEEE Journal of Selected Topics in Signal Processing
  • Kihwan Choi +2
  • Conference Article
  • Citations13

Self Supervised Low Dose Computed Tomography Image Denoising Using Invertible Network Exploiting Inter Slice Congruence

  • Jan 01, 2023
  • Sutanu Bera +1
  • Research Article
  • Citations11

A computer simulation method for low-dose CT images by use of real high-dose images: a phantom study.

  • Aug 20, 2015
  • Radiological physics and technology
  • Tomomi Takenaga +5
  • Research Article
  • Citations25

Evaluation of fully automated commercial software for Agatston calcium scoring on non-ECG-gated low-dose chest CT with different slice thickness.

  • Sep 24, 2022
  • European Radiology
  • Hyun Woo Kang +10
  • Research Article
  • Citations17

Low-dose x-ray CT simulation from an available higher-dose scan

  • Jul 03, 2020
  • Physics in Medicine & Biology
  • Masoud Elhamiasl +1
  • Research Article

Deep learning-based image analysis of pretreatment FDG-PET/CT predicts CAR-T cell treatment outcome at month-12 for patients with Relapsed/Refractory large B-cell lymphomas

  • Nov 03, 2025
  • Blood
  • Stephen Schuster +7
  • Research Article
  • Citations2

Technical performance of dual-contrast-agent K-edge imaging with four energy thresholds on a commercial photon counting detector CT.

  • Oct 01, 2025
  • Medical physics
  • Kevin J Treb +8
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.