• Home
  • Search
  • Quantitative image reconstruction for small-animal SPECT imaging including resolution recovery, scatter correction and attenuation correction.
  • https://doi.org/10.1016/j.ejmp.2026.105761Copy DOI Icon

Quantitative image reconstruction for small-animal SPECT imaging including resolution recovery, scatter correction and attenuation correction.

  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

High-resolution small-animal SPECT imaging plays a pivotal role in preclinical research by enabling quantitative visualization of radiopharmaceutical distribution in animal models. However, challenges, including physical degrading factors, such as photon attenuation, scattering, and limited spatial resolution hinder SPECT's quantitative accuracy. Advanced reconstruction algorithms are essential to mitigate these effects and enhance image fidelity. We developed a quantitative iterative reconstruction algorithm for the developed silicon photomultipliers (SiPMs)-based HiReSPECT II preclinical SPECT system, incorporating resolution recovery, attenuation correction, and scatter compensation. Resolution recovery was modelled using a distance-dependent Gaussian collimator-detector response (CDR). Attenuation correction was implemented via binary attenuation maps with photon path-length calculation using Siddon's ray-tracing method. Scatter correction was performed on list-mode data by estimating and subtracting scattered events using the Dual-Energy Window (DEW) technique. The reconstructed images were calibrated to absolute radiotracer concentration units. Quantitative imaging performance was validated using uniformity and NEMA NU 4-2008 image quality phantoms, followed by in vivo mouse imaging studies. The proposed algorithm significantly enhanced image quality and quantitative accuracy. Resolution recovery improved sharpness, while scatter and attenuation corrections minimized artifacts and ensured uniformity. Key metrics demonstrated substantial improvements in contrast, uniformity and resolution. Quantitative accuracy also significantly improved. Incorporating resolution recovery, scatter correction, and attenuation correction into preclinical SPECT image reconstruction is critical for achieving high quantitative accuracy. The integration of these techniques in systems, such as HiReSPECT II, establishes a new benchmark for preclinical imaging, facilitating radiotracer development and advancing translational research.

Similar Papers
  • Research Article
  • Citations10

Impact of scatter and attenuation corrections for iodine-131 two-dimensional quantitative imaging in patients.

  • Apr 01, 2003
  • Cancer Biotherapy and Radiopharmaceuticals
  • Grégory Delpon +3
  • Research Article
  • Citations35

Scatter correction improves concordance in SPECT MPI with a dedicated cardiac SPECT solid-state camera

  • Apr 01, 2015
  • Journal of Nuclear Cardiology
  • Amir Pourmoghaddas +3
  • PDF
  • Research Article
  • Citations7

DAcquisition setting optimization and quantitative imaging for 124I studies with the Inveon microPET-CT system

  • Jan 01, 2012
  • EJNMMI Research
  • Nadège Anizan +4
  • Research Article
  • Citations3

Does applying resolution recovery to normal databases confer an advantage over conventional 3D-stereotactic surface projection techniques?

  • Feb 04, 2017
  • Radiological physics and technology
  • Nobuhiro Yada +9
  • Conference Article

Effects of collimator dependency and correction methods on I-123 SPECT images using x-ray-based attenuation map

  • Mar 02, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yu-Wen Yang +4
  • Research Article

Deep learning-guided attenuation and scatter correction of 99mTc-MAA SPECT images: towards quantitative analysis in 90Y-SIRT.

  • Jan 05, 2026
  • Annals of nuclear medicine
  • Zahra Mansouri +6
  • PDF
  • Research Article

Evaluation of Single-Photon Emission Computed Tomography Myocardial Perfusion Detection Capability through Physical Descriptors

  • Jun 18, 2024
  • Applied Sciences
  • Dea Dundara Debeljuh +4
  • Research Article

Optimization of the Attenuation Coefficient for Chang Attenuation Correction in 123I Brain Perfusion SPECT.

  • Feb 07, 2023
  • Journal of nuclear medicine technology
  • Taisuke Murata +8
  • Research Article
  • Citations8

Effect of Prefiltering Cutoff Frequency and Scatter and Attenuation Corrections During Normal Database Creation for Statistical Imaging Analysis of the Brain

  • Jul 27, 2011
  • Journal of Nuclear Medicine Technology
  • H Onishi +4
  • Research Article
  • Citations50

Improved quantification in single-pinhole and multiple-pinhole SPECT using micro-CT information

  • Feb 14, 2009
  • European Journal of Nuclear Medicine and Molecular Imaging
  • Christian Vanhove +3
  • Research Article
  • Citations23

Evaluation of scatter compensation strategies and their impact on human detection performance Tc-99m myocardial perfusion imaging

  • Oct 01, 2003
  • IEEE Transactions on Nuclear Science
  • M.V Narayanan +8
  • Research Article
  • Citations60

Hybrid scatter correction applied to quantitative holmium-166 SPECT

  • Sep 08, 2006
  • Physics in Medicine & Biology
  • Tim C De Wit +6
  • Research Article
  • Citations8

Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction

  • Mar 01, 2012
  • Nuclear Medicine Communications
  • Faraz Kalantari +2
  • Research Article
  • Citations16

Scatter Characterization and Correction for Simultaneous Multiple Small-Animal PET Imaging

  • Aug 29, 2013
  • Molecular Imaging and Biology
  • Rameshwar Prasad +1
  • PDF
  • Research Article
  • Citations20

Effects of voxel size and iterative reconstruction parameters on the spatial resolution of 99mTc SPECT/CT

  • Sep 01, 2011
  • Journal of applied clinical medical physics / American College of Medical Physics
  • S Cheenu Kappadath
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.