Reduced anatomical clutter in digital breast tomosynthesis with statistical iterative reconstruction

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Purpose:Digital breast tomosynthesis (DBT) has been shown to somewhat alleviate the breast tissue overlapping issues of two-dimensional (2D) mammography. However, the improvement in current DBT systems over mammography is still limited. Statistical image reconstruction (SIR) methods have the potential to reduce through-plane artifacts in DBT, and thus may be used to further reduce anatomical clutter. The purpose of this work was to study the impact of SIR on anatomical clutter in the reconstructed DBT image volumes.Methods:An SIR with a slice-wise total variation (TV) regularizer was implemented to reconstruct DBT images which were compared with the clinical reconstruction method (filtered backprojection). The artifact spread function (ASF) was measured to quantify the reduction of the through-plane artifacts level in phantom studies and microcalcifications in clinical cases. The anatomical clutter was quantified by the anatomical noise power spectrum with a power law fitting model: NPSa(f) = αf–β. The β values were measured from the reconstructed image slices when the two reconstruction methods were applied to a cohort of clinical breast exams (N = 101) acquired using Hologic Selenia Dimensions DBT systems.Results:The full width half maximum (FWHM) of the measured ASF was reduced from 8.7 ± 0.1 mm for clinical reconstruction to 6.5 ± 0.1 mm for SIR which yields a 25% reduction in FWHM in phantom studies and the same amount of ASF reduction was also found in clinical measurements from microcalcifications. The measured β values for the two reconstruction methods were 3.17 ± 0.36 and 2.14 ± 0.39 for the clinical reconstruction method and the SIR method, respectively. This difference was statistically significant (P ≪ 0.001). The dependence of β on slice location using either method was negligible.Conclusions:Statistical image reconstruction enabled a significant reduction of both the through-plane artifacts level and anatomical clutter in the DBT reconstructions. The β value was found to be β≈2.14 with the SIR method. This value stays in the middle between the β≈1.8 for cone beam CT and β≈3.2 for mammography. In contrast, the measured β value in the clinical reconstructions (β≈3.17) remains close to that of mammography.

Similar Papers
  • Research Article
  • Citations65

Regularization strategies in statistical image reconstruction of low-dose X-ray CT: A review

  • Sep 10, 2018
  • Medical physics
  • Hao Zhang +4
  • Conference Article
  • Citations1

Bayesian reconstruction for digital breast tomosynthesis using a non-local Gaussian Markov random field a priori model

  • Mar 01, 2019
  • Medical Imaging 2019: Physics of Medical Imaging
  • Denis Salvadeo +3
  • Book Chapter
  • Citations8

Chapter 40 - GPU Acceleration of Iterative Digital Breast Tomosynthesis

  • Jan 01, 2011
  • GPU Computing Gems Emerald Edition
  • Dana Schaa +7
  • Research Article
  • Citations31

Quantifying the Importance of the Statistical Assumption in Statistical X-ray CT Image Reconstruction

  • Aug 30, 2013
  • IEEE Transactions on Medical Imaging
  • Jingyan Xu +1
  • Conference Article
  • Citations3

Study of image quality in digital breast tomosynthesis by subpixel reconstruction

  • Mar 19, 2013
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Yao Lu +4
  • Conference Article
  • Citations6

Scan time optimization for post-injection PET scans

  • Nov 08, 1998
  • H Erdogan +1
  • Research Article
  • Citations38

Statistical image reconstruction from limited projection data with intensity priors

  • Mar 20, 2012
  • Physics in Medicine and Biology
  • Essam A Rashed +1
  • Research Article

MO-DE-209-01: Primer On Tomosynthesis

  • Jun 01, 2016
  • Medical Physics
  • A Maidment
  • Research Article
  • Citations3

An adaptive multiscale anisotropic diffusion regularized image reconstruction method for digital breast tomosynthesis.

  • Oct 29, 2018
  • Australasian Physical & Engineering Sciences in Medicine
  • Yangchuan Liu +4
  • Research Article
  • Citations1

Patient-Specific Minimum-Dose Imaging Protocols for Statistical Image Reconstruction in C-arm Cone-Beam CT Using Correlated Noise Injection.

  • Mar 19, 2014
  • Proceedings of SPIE--the International Society for Optical Engineering
  • A S Wang +5
  • PDF
  • Research Article
  • Citations13

Evaluation of a Generative Adversarial Network to Improve Image Quality and Reduce Radiation-Dose during Digital Breast Tomosynthesis

  • Feb 14, 2022
  • Diagnostics
  • Tsutomu Gomi +3
  • Research Article
  • Citations731

Statistical image reconstruction for polyenergetic X-ray computed tomography.

  • Jan 01, 2002
  • IEEE Transactions on Medical Imaging
  • I.A Elbakri +1
  • Abstract

75. Image quality and dose measurements in digital breast tomosynthesis

  • Dec 01, 2018
  • Physica Medica
  • O Ortenzia +4
  • Research Article

Image reconstruction for digital breast tomosynthesis (DBT) by using projection-angle-dependent filter functions

  • Sep 01, 2014
  • Journal of the Korean Physical Society
  • Yeonok Park +8
  • Conference Article
  • Citations1

Dose reduction in breast imaging: A phantom study

  • Mar 01, 2015
  • Surangkana Kantharak +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.