Abstract

Previous methods for optimizing the scan times for PET transmission and emission scans under a total scan time constraint were based on linear non-statistical methods and used noise equivalent counts (NEC) criteria. The scan times determined by NEC analysis may be suboptimal when nonlinear statistical image reconstruction methods are used. For statistical image reconstruction, the predicted variance in selected regions of interest is an appropriate alternative to NEC analysis. The authors propose a new method for optimizing the relative scan times (fractions) based on analytical approximations to the covariance of images reconstructed by both conventional and penalized-likelihood methods. The authors perform simulations to compare predicted standard deviations with empirical ones. Results show that for statistical transmission image reconstruction, the optimal fraction of the scan time devoted to transmission scanning is shorter than for conventional transmission smoothing.

Similar Papers
  • Research Article
  • Citations31

Quantifying the Importance of the Statistical Assumption in Statistical X-ray CT Image Reconstruction

  • Aug 30, 2013
  • IEEE Transactions on Medical Imaging
  • Jingyan Xu +1
  • Research Article
  • Citations38

Statistical image reconstruction from limited projection data with intensity priors

  • Mar 20, 2012
  • Physics in Medicine and Biology
  • Essam A Rashed +1
  • Research Article
  • Citations17

Reduced anatomical clutter in digital breast tomosynthesis with statistical iterative reconstruction

  • Apr 01, 2018
  • Medical physics
  • John W Garrett +3
  • Research Article
  • Citations65

Regularization strategies in statistical image reconstruction of low-dose X-ray CT: A review

  • Sep 10, 2018
  • Medical physics
  • Hao Zhang +4
  • Research Article
  • Citations1

Patient-Specific Minimum-Dose Imaging Protocols for Statistical Image Reconstruction in C-arm Cone-Beam CT Using Correlated Noise Injection.

  • Mar 19, 2014
  • Proceedings of SPIE--the International Society for Optical Engineering
  • A S Wang +5
  • Conference Article

Optimal coincidence time window for ECAT exact HR plus

  • Nov 09, 1997
  • Yuan-Chuan Tai +2
  • Research Article
  • Citations731

Statistical image reconstruction for polyenergetic X-ray computed tomography.

  • Jan 01, 2002
  • IEEE Transactions on Medical Imaging
  • I.A Elbakri +1
  • Research Article
  • Citations56

Noise‐resolution tradeoffs in x‐ray CT imaging: A comparison of penalized alternating minimization and filtered backprojection algorithms

  • Feb 22, 2011
  • Medical Physics
  • Joshua D Evans +4
  • Research Article
  • Citations34

Effective count rates for PET scanners with reduced and extended axial field of view

  • May 25, 2011
  • Physics in Medicine & Biology
  • L R Macdonald +5
  • Research Article

TU‐D‐207A‐00: Quantitative Assessment of CT Systems with Iterative Image Reconstruction Algorithms

  • Jun 01, 2016
  • Medical Physics
  • Guang‐Hong Chen +1
  • Research Article
  • Citations17

Assessment of prior image induced nonlocal means regularization for low-dose CT reconstruction: change in anatomy

  • Sep 01, 2017
  • Medical physics
  • Hao Zhang +4
  • Conference Article

A unified approach to statistical image reconstruction using dual ascent optimization

  • Oct 16, 2004
  • Meihua Li +1
  • Research Article
  • Citations62

Soft-tissue imaging with C-arm cone-beam CT using statistical reconstruction

  • Feb 07, 2014
  • Physics in Medicine and Biology
  • Adam S Wang +7
  • Research Article
  • Citations47

Study of PET scanner designs using clinical metrics to optimize the scanner axial FOV and crystal thickness

  • May 17, 2013
  • Physics in Medicine and Biology
  • S Surti +2
  • Book Chapter
  • Citations23

Large-Scale Non-Linear 3D Reconstruction Algorithms for Electrical Impedance Tomography of the Human Head

  • Jan 01, 2007
  • Lior Horesh +3
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.