Single‐scan patient‐specific scatter correction in computed tomography using peripheral detection of scatter and compressed sensing scatter retrieval

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

X-ray scatter results in a significant degradation of image quality in computed tomography (CT), representing a major limitation in cone-beam CT (CBCT) and large field-of-view diagnostic scanners. In this work, a novel scatter estimation and correction technique is proposed that utilizes peripheral detection of scatter during the patient scan to simultaneously acquire image and patient-specific scatter information in a single scan, and in conjunction with a proposed compressed sensing scatter recovery technique to reconstruct and correct for the patient-specific scatter in the projection space. The method consists of the detection of patient scatter at the edges of the field of view (FOV) followed by measurement based compressed sensing recovery of the scatter through-out the projection space. In the prototype implementation, the kV x-ray source of the Varian TrueBeam OBI system was blocked at the edges of the projection FOV, and the image detector in the corresponding blocked region was used for scatter detection. The design enables image data acquisition of the projection data on the unblocked central region of and scatter data at the blocked boundary regions. For the initial scatter estimation on the central FOV, a prior consisting of a hybrid scatter model that combines the scatter interpolation method and scatter convolution model is estimated using the acquired scatter distribution on boundary region. With the hybrid scatter estimation model, compressed sensing optimization is performed to generate the scatter map by penalizing the L1 norm of the discrete cosine transform of scatter signal. The estimated scatter is subtracted from the projection data by soft-tuning, and the scatter-corrected CBCT volume is obtained by the conventional Feldkamp-Davis-Kress algorithm. Experimental studies using image quality and anthropomorphic phantoms on a Varian TrueBeam system were carried out to evaluate the performance of the proposed scheme. The scatter shading artifacts were markedly suppressed in the reconstructed images using the proposed method. On the Catphan©504 phantom, the proposed method reduced the error of CT number to 13 Hounsfield units, 10% of that without scatter correction, and increased the image contrast by a factor of 2 in high-contrast regions. On the anthropomorphic phantom, the spatial nonuniformity decreased from 10.8% to 6.8% after correction. A novel scatter correction method, enabling unobstructed acquisition of the high frequency image data and concurrent detection of the patient-specific low frequency scatter data at the edges of the FOV, is proposed and validated in this work. Relative to blocker based techniques, rather than obstructing the central portion of the FOV which degrades and limits the image reconstruction, compressed sensing is used to solve for the scatter from detection of scatter at the periphery of the FOV, enabling for the highest quality reconstruction in the central region and robust patient-specific scatter correction.

Similar Papers
  • Research Article
  • Citations10

A correlated sampling-based Monte Carlo simulation for fast CBCT iterative scatter correction.

  • Nov 25, 2022
  • Medical Physics
  • Peishan Qin +9
  • Conference Article
  • Citations2

Rapid optimization of SPECT scatter correction using model LROC observers

  • Jan 01, 2007
  • S Kulkarni +3
  • Research Article
  • Citations12

Scatter correction method for cone-beam CT based on interlacing-slit scan

  • Jul 16, 2014
  • Chinese Physics B
  • Kui-Dong Huang +4
  • Research Article
  • Citations9

Algorithmic scatter correction in dual-energy digital mammography

  • Oct 25, 2013
  • Medical Physics
  • Xi Chen +5
  • Research Article
  • Citations1

TU‐D‐I‐611‐06: A Direct, Empirical Method for X‐Ray Scatter Correction in Digital Radiography and Cone‐Beam CT

  • May 26, 2005
  • Medical Physics
  • J Siewerdsen +6
  • Research Article
  • Citations106

Scatter correction for full‐fan volumetric CT using a stationary beam blocker in a single full scan

  • Oct 20, 2011
  • Medical Physics
  • Tianye Niu +1
  • Research Article
  • Citations3

A comparative investigation of scatter correction in 3D PET

  • Sep 23, 2011
  • Journal of Physics: Conference Series
  • I Polycarpou +2
  • Research Article
  • Citations3

WE-G-134-03: A Moving Blocker System for Cone-Beam Computed Tomography Scatter Correction

  • Jun 01, 2013
  • Medical Physics
  • L Ouyang +3
  • Research Article
  • Citations2

Study of multispectral frame-by-frame convolution scatter correction in high resolution PET

  • Dec 01, 1997
  • IEEE Transactions on Nuclear Science
  • R Yao +2
  • Research Article
  • Citations1

Validierung einer Streukorrekturmethode zur IMRT-Verifikation mit Hilfe eines Portal-Imaging-Systems

  • Jan 01, 2004
  • Zeitschrift fuer Medizinische Physik
  • Ina Kyas +4
  • Research Article

Validation of a TOPAS cone beam computed tomography (CBCT) Monte Carlo model towards personalised CBCT dosimetry in interventional radiology (IR).

  • Jan 01, 2026
  • Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
  • Nina Mcwilliams +3
  • Research Article
  • Citations5

A weighted rebinned backprojection-filtration algorithm from partially beam-blocked data for a single-scan cone-beam CT with hybrid type scatter correction.

  • Jan 25, 2019
  • Medical physics
  • Jonghwan Min +6
  • Conference Article

Robust Estimation of Scatter and Primary Signals using Multi-View Information for Moving BlockerBased Cone-Beam Computed Tomography

  • Oct 01, 2017
  • Cong Zhao +4
  • Research Article
  • Citations1

Scatter correction for clinical cone beam CT breast imaging based on breast phantom studies

  • Feb 01, 2011
  • Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics
  • Weixing Cai +2
  • Conference Article
  • Citations1

A penalized weighted least-squares image reconstruction based on scatter correction methods for X-ray CT

  • Jul 11, 2013
  • Long Qing Chen +2
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.