• Home
  • Search
  • A correlated sampling-based Monte Carlo simulation for fast CBCT iterative scatter correction.
  • Cite Icon10
  • https://doi.org/10.1002/mp.16073Copy DOI Icon

A correlated sampling-based Monte Carlo simulation for fast CBCT iterative scatter correction.

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

In recent years, cone-beam computed tomography (CBCT) has played an important role in medical imaging. However, the applications of CBCT are limited due to the severe scatter contamination. Conventional Monte Carlo (MC) simulation can provide accurate scatter estimation for scatter correction, but the expensive computational cost has always been the bottleneck of MC method in clinical application. In this work, an MC simulation method combined with a variance reduction technique called correlated sampling is proposed for fast iterative scatter correction. Correlated sampling exploits correlation between similar simulation systems to reduce the variance of interest quantities. Specifically, conventional MC simulation is first performed on the scatter-contaminated CBCT to generate the initial scatter signal. In the subsequent correction iterations, scatter estimation is then updated by applying correlated MC sampling to the latest corrected CBCT images by reusing the random number sequences of the task-related photons in conventional MC. Afterward, the corrected projections obtained by subtracting the scatter estimation from raw projections are utilized for FDK reconstruction. These steps are repeated until an adequate scatter correction is obtained. The performance of the proposed framework is evaluated by the accuracy of the scatter estimation, the quality of corrected CBCT images and efficiency. Overall, the difference in mean absolute percentage error between scatter estimation with and without correlated sampling is 0.25% for full-fan case and 0.34% for half-fan case, respectively. In simulation studies, scatter artifacts are substantially eliminated, where the mean absolute error value is reduced from 15 to 2HU in full-fan case and from 53 to 13HU in half-fan case. Scatter-to-primary ratio is reduced to 0.02 for full-fan and 0.04 for half-fan, respectively. In phantom study, the contrast-to-noise ratio (CNR) is increased by a factor of 1.63, and the contrast is increased by a factor of 1.77. As for clinical studies, the CNR is improved by 11% and 14% for half-fan and full-fan, respectively. The contrast after correction is increased by 19% for half-fan and 44% for full-fan. Furthermore, root mean square error is also effectively reduced, especially from 78 to 4HU for full-fan. Experimental results demonstrate that the figure of merit is improved between 23 and 43 folds when using correlated sampling. The proposed method takes less than 25s for the whole iterative scatter correction process. The proposed correlated sampling-based MC simulation method can achieve fast and accurate scatter correction for CBCT, making it suitable for real-time clinical use.

Similar Papers
  • Research Article
  • Citations80

A model-based scatter artifacts correction for cone beam CT.

  • Mar 18, 2016
  • Medical Physics
  • Wei Zhao +4
  • PDF
  • Research Article
  • Citations1

Scatter Correction for Industrial Cone-Beam Computed Tomography (CBCT) Using VSHARP, a fast GPU-Based Linear Boltzmann Transport Equation Solver

  • Mar 01, 2019
  • e-Journal of Nondestructive Testing
  • Amy Shiroma +12
  • Research Article
  • Citations1

TU‐D‐I‐611‐06: A Direct, Empirical Method for X‐Ray Scatter Correction in Digital Radiography and Cone‐Beam CT

  • May 26, 2005
  • Medical Physics
  • J Siewerdsen +6
  • Research Article
  • Citations1

WE‐AB‐207A‐07: A Planning CT‐Guided Scatter Artifact Correction Method for CBCT Images

  • Jun 01, 2016
  • Medical Physics
  • X Yang +5
  • Research Article
  • Citations5

UBES: Unified scatter correction using ultrafast Boltzmann equation solver for conebeam CT

  • Feb 05, 2024
  • Computers in Biology and Medicine
  • Tianye Niu +10
  • Conference Article
  • Citations18

Scatter correction for kilovoltage cone-beam computed tomography (CBCT) images using Monte Carlo simulations

  • Mar 02, 2006
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • G Jarry +4
  • Research Article
  • Citations191

Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations

  • Oct 24, 2006
  • Medical Physics
  • Geneviève Jarry +5
  • Research Article
  • Citations15

Single‐scan patient‐specific scatter correction in computed tomography using peripheral detection of scatter and compressed sensing scatter retrieval

  • Dec 26, 2012
  • Medical Physics
  • Bowen Meng +3
  • Research Article
  • Citations119

Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

  • Apr 25, 2013
  • Medical Physics
  • A Sisniega +6
  • Research Article

Validation of a TOPAS cone beam computed tomography (CBCT) Monte Carlo model towards personalised CBCT dosimetry in interventional radiology (IR).

  • Jan 01, 2026
  • Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)
  • Nina Mcwilliams +3
  • Conference Article
  • Citations6

Dose and scatter characteristics of a novel cone beam CT system for musculoskeletal extremities

  • Feb 23, 2012
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • W Zbijewski +9
  • Research Article

MO-D-BRC-06: A Multi-Exposure Approach to Improve Image Quality for Linac-Based Cone Beam Computed Tomography (CBCT)

  • Jun 01, 2011
  • Medical Physics
  • J Jin +5
  • Research Article
  • Citations17

Cone-beam imaging with tilted rotation axis: Method and performance evaluation.

  • May 22, 2020
  • Medical Physics
  • Chumin Zhao +6
  • Research Article
  • Citations77

An efficient and exact stochastic simulation method to analyze rare events in biochemical systems

  • Oct 22, 2008
  • The Journal of Chemical Physics
  • Hiroyuki Kuwahara +1
  • Research Article
  • Citations27

Density of Configurational States from First‐Principles Calculations: The Phase Diagram of Al–Na Surface Alloys

  • Sep 05, 2005
  • ChemPhysChem
  • Mikael Borg +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.