Abstract

The subsynchronous resonance (SSR) phenomenon may occur when a steam turbine-generator is connected to a long transmission line with series compensation. The main purpose of this works is to verify the capability of the gate controlled series capacitor (GCSC) to mitigate SSR. For this study the GCSC was tested in conjunction with the first IEEE benchmark system. The actual possibility of controlling SSR was verified by digital simulation using the ATP/EMTP (alternative transients program/electromagnetic transients program). As a result it was shown that GCSC is a powerful device for controlled series compensation both for power flow control and SSR damping. It was shown also that in some case the GCSC can damp SSR even without a specific control. GCSC can also damp electromechanical power oscillations as shown in some simulations

Similar Papers
  • Conference Article
  • Citations11

Analysis of SSR Mitigation Using Gate Controlled Series Capacitors

  • Jun 16, 2005
  • F Jesus +3
  • Conference Article
  • Citations44

SSR analysis of a DFIG-based wind farm interfaced with a gate-controlled series capacitor

  • Mar 01, 2014
  • Hossein Ali Mohammadpour +2
  • PDF
  • Research Article
  • Citations3

Mitigation of SSR with STATCOM using Subsynchronous Damping Controller on Series-Compensated Transmission Line

  • Dec 15, 2016
  • Indian Journal of Science and Technology
  • Natasha Singla +2
  • Conference Article
  • Citations1

Effect of $\text{FOIDN}+\text{TID}$ Damping Controller based GCSC on Load Frequency Control

  • Dec 16, 2020
  • Sumana Das +2
  • Research Article
  • Citations16

Mitigation of SSR by Subsynchronous Current Injection with VSC HVDC

  • Dec 23, 2013
  • International Journal of Electrical Power & Energy Systems
  • M Janaki +3
  • PDF
  • Research Article
  • Citations10

Analysis and Mitigation of Subsynchronous Resonance in a Korean Power Network with the First TCSC Installation

  • Jul 24, 2019
  • Energies
  • Minh-Quan Tran +6
  • Conference Article
  • Citations3

Computational approach to optimal damping controller design for a GCSC

  • Jul 01, 2008
  • Swakshar Ray +2
  • Conference Article
  • Citations2

Remote signal STATCOM controller for mitigation of sub-synchronous resonance in series compensated type 3 wind farm

  • Aug 01, 2017
  • Gajanan V Gotmare +1
  • Conference Article
  • Citations1

Subsynchronous Resonance Mitigation in SMIB System Using GCSC and TCSC with Conventional and Fuzzy Logic Controllers

  • Jan 05, 2023
  • J Sreeranganayakulu +2
  • Research Article

On the possibility of SSR in longitudinal power systems

  • Dec 13, 1999
  • Electrical Engineering in Japan
  • Naoto Kakimoto +2
  • PDF
  • Research Article
  • Citations19

Subsynchronous Resonance and FACTS-Novel Control Strategy for Its Mitigation

  • Jul 14, 2019
  • Journal of Engineering
  • Doan Duc Tung +2
  • Research Article

Mitigating Subsynchronous Resonance in Doubly Fed Wind Turbine Induction Generator Using FACTS Devices: A Comparative Case Study

  • Dec 24, 2024
  • International Journal of Robotics and Control Systems
  • Bui Thi Hoa Phuong +3
  • Research Article
  • Citations37

Mitigation of Subsynchronous Resonance with Fractional-order PI based UPFC controller

  • Sep 17, 2016
  • Mechanical Systems and Signal Processing
  • D Koteswara Raju +3
  • Conference Article
  • Citations3

Review and Analysis of Techniques to Mitigate Sub Synchronous Resonance using FACTS Devices

  • May 05, 2022
  • G Ramya +4
  • Conference Article
  • Citations3

Impact of location and composition of dynamic load on the severity of SSR in meshed power systems

  • Jun 01, 2017
  • Papiya Dattaray +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.