• Home
  • Search
  • Studies and Validation of a CMS Drift Tube Trigger Algorithm for HL-LHC
  • https://doi.org/10.1109/nss/mic42101.2019.9059661Copy DOI Icon

Studies and Validation of a CMS Drift Tube Trigger Algorithm for HL-LHC

  • Oct 1, 2019
  • C.a Carrillo
Show More
  • Abstract
  • Literature Map
  • References
  • Similar Papers
Abstract

The electronics of the CMS (Compact Muon Solenoid) DT (Drift Tubes) chambers will need to be replaced for the HL-LHC (High Luminosity Large Hadron Collider) operation due to the increase of occupancy and trigger rates in the detector, which cannot be sustained by the present system. A new system is being designed that will forward asynchronously the totality of the chamber signals to the control room, at full resolution. A new back-end system will be in charge of building the trigger primitives of each chamber out of this asynchronous information, aiming at achieving resolutions comparable to the ones that the offline High Level Trigger can obtain nowadays. In this way, the new system will provide better functionality with respect to the present system, allowing to improve the resilience to potential aging situations. An algorithm, called the Analytical Method (AM), has been designed for this new backed system following a simplified, hardware-oriented procedure optimizing the FPGA resources. The performance of this algorithm has been validated through different methods: from a software emulation approach to hardware implementation tests. The performance obtained is very good, with optimal timing and position resolutions, close to the ultimate performance of the DT chamber system. One important validation step has included the implementation of this algorithm in a prototype chain of the HLLHC electronics, which has been operated with real DT chambers under cosmic data taking campaigns. The new trigger primitive generation has been implemented in spare uTCA boards from the present DT system which host Xilinx Virtex 7 FPGAs. The performance of this prototyping/algorithm has been verified and will be presented in this contribution.

Similar Papers
  • Research Article

Upgrade of the CMS Drift Tube system for the High Luminosity LHC

  • Jan 01, 2026
  • Journal of Instrumentation
  • Leonardo Lunerti
  • Research Article

Background in the CMS drift tubes: measurements with LHC collision data and implications for detector longevity at HL-LHC

  • Sep 01, 2022
  • Journal of Instrumentation
  • L Borgonovi
  • Research Article
  • Citations1

Trigger primitive generation algorithm in the CMS barrel muon chambers during HL-LHC

  • Dec 01, 2021
  • Journal of Instrumentation
  • N Trevisani
  • Research Article

Performance tests of the drift tube Muon chambers for the CMS experiment at the LHC

  • Sep 01, 2003
  • Nuclear Physics B - Proceedings Supplements
  • F.R Cavallo
  • Research Article
  • Citations2

Upgrade of the CMS Drift Tube electronics for the High Luminosity LHC

  • Jan 01, 2025
  • Journal of Instrumentation
  • C.F Bedoya
  • Conference Article

Performance of a first-level muon trigger with high momentum resolution based on the ATLAS MDT chambers for HL-LHC

  • Oct 01, 2015
  • P Gadow +5
  • Conference Article

The CMS Muon detectors

  • Jan 01, 2007
  • M.C Fouz
  • Conference Article

The Phase-II upgrade of the ATLAS Muon Spectrometer

  • Sep 30, 2020
  • Antonio Policicchio
  • Research Article
  • Citations7

Radiation testing of electronics for the CMS endcap muon system

  • Sep 17, 2012
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • B Bylsma +16
  • Research Article
  • Citations3

Performance of Michigan sMDT prototype chambers for the HL-LHC ATLAS muon detector upgrade

  • Nov 01, 2021
  • Journal of Instrumentation
  • K Nelson +3
  • Single Book

From Detector Development to New Physics Searches: CMS HGCAL Validation and Search for Top-Philic Resonances Using Variable-Radius Jet Tagging

  • Feb 12, 2026
  • DESY Publication Database (PUBDB) (Deutsches Elektronen-Synchrotron)
  • G Milella
  • Research Article
  • Citations4

Precision Timing in the CMS MTD Barrel Timing Layer With Crystal Bars and SiPMs

  • Jul 14, 2020
  • IEEE Transactions on Nuclear Science
  • Francesco Santanastasio
  • Research Article
  • Citations3

Process quality control strategy for the Phase-2 Upgrade of the CMS Outer Tracker and High Granularity Calorimeter

  • Aug 21, 2020
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
  • V Hinger
  • PDF
  • Research Article

Trigger Rate Monitoring Tools at CMS

  • Jan 01, 2019
  • EPJ Web of Conferences
  • Andrew Wightman +3
  • Conference Article
  • Citations1

Operation and performance of the CMS Level-1 Calorimeter Trigger upgrade

  • Oct 01, 2015
  • P Klabbers
Cactus Communications logo