• Home
  • Search
  • SU-E-I-91: Development of a Compact Radiographic Simulator Using Microsoft Kinect.
  • Cite Icon1
  • https://doi.org/10.1118/1.4734808Copy DOI Icon

SU-E-I-91: Development of a Compact Radiographic Simulator Using Microsoft Kinect.

Show More
  • Abstract
  • Literature Map
  • Citations
  • Similar Papers
Abstract

Radiographic simulator system is useful for learning radiographic techniques and confirmation of positioning before x-ray irradiation. Conventional x-ray simulators have drawbacks in cost and size, and are only applicable to situations in which position of the object does not change. Therefore, we have developed a new radiographic simulator system using an infrared-ray based three-dimensional shape measurement device (Microsoft Kinect). We made a computer program using OpenCV and OpenNI for processing of depth image data obtained from Kinect, and calculated the exact distance from Kinect to the object by calibration. Theobject was measured from various directions, and positional relationship between the x-ray tube and the object was obtained. X-ray projection images were calculated by projecting x-rays onto the mathematical three-dimensional CT data of a head phantom with almost the same size. The object was rotated from 0 degree (standard position) through 90 degrees in increments of 10 degrees, and the accuracy of the measured rotation angle values was evaluated. In order to improve the computational time, the projection image size was changed (512*512, 256*256, and 128*128). The x-ray simulation images corresponding to the radiographic images produced by using the x-ray tube were obtained. The three-dimensional position of the object was measured with good precision from 0 to 50 degrees, but above 50 degrees, measured position error increased with the increase of the rotation angle. The computational time and image size were 30, 12, and 7 seconds for 512*512, 256*256, and 128*128, respectively. We could measure the three-dimensional position of the object using properly calibrated Kinect sensor, and obtained projection images at relatively high-speed using the three-dimensional CTdata. It was suggested that this system can be used for obtaining simulated projection x-ray images before x-ray exposure by attaching this device onto an x-ray tube.

Similar Papers
  • Research Article
  • Citations44

A method for volumetric imaging in radiotherapy using single x-ray projection.

  • May 01, 2015
  • Medical Physics
  • Yuan Xu +7
  • Research Article
  • Citations31

Robust automatic rigid registration of MRI and X‐ray using external fiducial markers for XFM‐guided interventional procedures

  • Dec 16, 2010
  • Medical Physics
  • Ashvin K George +3
  • Research Article
  • Citations1

Image up-sampling method for dual-radiation nondestructive cargo inspection system

  • Jun 17, 2024
  • Nuclear Inst. and Methods in Physics Research, A
  • Hwanhui Jo +2
  • Research Article
  • Citations24

Markerless real-time 3-D target region tracking by motion backprojection from projection images

  • Nov 01, 2005
  • IEEE Transactions on Medical Imaging
  • T Rohlfing +4
  • Research Article
  • Citations7

Modeling of small carbon fiber-reinforced polymers for X-ray imaging simulation

  • Sep 07, 2014
  • Journal of Composite Materials
  • K Bliznakova +5
  • Research Article
  • Citations13

Novel-view X-ray projection synthesis through geometry-integrated deep learning.

  • Apr 01, 2022
  • Medical image analysis
  • Liyue Shen +4
  • Research Article
  • Citations86

Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter \u2013 Part I: Core algorithms and validation

  • Apr 06, 2018
  • Medical physics
  • Alexander Maslowski +5
  • Abstract

I227] Physics, technology and QC of breast tomosynthesis

  • Aug 01, 2018
  • Physica Medica
  • Anders Tingberg
  • Research Article
  • Citations1

A 3D Kinematic Measurement of Knee Prosthesis Using X-ray Projection Images (Experimental Verification of the Algorithm Using CCD Images)

  • Jan 01, 2003
  • TRANSACTIONS OF THE JAPAN SOCIETY OF MECHANICAL ENGINEERS Series C
  • Yuki Tomonaga +2
  • Research Article
  • Citations3

Registration of on-board X-ray images with 4DCT: A proposed method of phase and setup verification for gated radiotherapy

  • Oct 02, 2009
  • Physica Medica
  • Qianyi Xu +6
  • Research Article
  • Citations2

Color impact on security screening

  • Oct 01, 2010
  • IEEE Aerospace and Electronic Systems Magazine
  • Claudia C Von Bastian +2
  • Research Article
  • Citations26

A comparative study of a dual‐energy‐like imaging technique based on counting‐integrating readout

  • Nov 10, 2011
  • Medical Physics
  • Ewald Roessl +3
  • Research Article

Assessment of compliance levels of effective doses in pediatric CT

  • Dec 01, 2018
  • Iranian Journal of Medical Physics
  • Dheyauldeen Shabeeb +1
  • Research Article
  • Citations15

A projection image database to investigate factors affecting image quality in weight-based dosing: application to pediatric renal SPECT

  • Jul 01, 2018
  • Physics in Medicine & Biology
  • Ye Li +10
  • Research Article
  • Citations3

Radiation safety protocol in dentistry: A neglected practice

  • Jan 01, 2018
  • Journal of Orofacial Sciences
  • Anu Premkumar +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.