• Home
  • Search
  • Markerless real-time 3-D target region tracking by motion backprojection from projection images
  • Cite Icon24
  • https://doi.org/10.1109/tmi.2005.857651Copy DOI Icon

Markerless real-time 3-D target region tracking by motion backprojection from projection images

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Accurate and fast localization of a predefined target region inside the patient is an important component of many image-guided therapy procedures. This problem is commonly solved by registration of intraoperative 2-D projection images to 3-D preoperative images. If the patient is not fixed during the intervention, the 2-D image acquisition is repeated several times during the procedure, and the registration problem can be cast instead as a 3-D tracking problem. To solve the 3-D problem, we propose in this paper to apply 2-D region tracking to first recover the components of the transformation that are in-plane to the projections. The 2-D motion estimates of all projections are backprojected into 3-D space, where they are then combined into a consistent estimate of the 3-D motion. We compare this method to intensity-based 2-D to 3-D registration and a combination of 2-D motion backprojection followed by a 2-D to 3-D registration stage. Using clinical data with a fiducial marker-based gold-standard transformation, we show that our method is capable of accurately tracking vertebral targets in 3-D from 2-D motion measured in X-ray projection images. Using a standard tracking algorithm (hyperplane tracking), tracking is achieved at video frame rates but fails relatively often (32% of all frames tracked with target registration error (TRE) better than 1.2 mm, 82% of all frames tracked with TRE better than 2.4 mm). With intensity-based 2-D to 2-D image registration using normalized mutual information (NMI) and pattern intensity (PI), accuracy and robustness are substantially improved. NMI tracked 82% of all frames in our data with TRE better than 1.2 mm and 96% of all frames with TRE better than 2.4 mm. This comes at the cost of a reduced frame rate, 1.7 s average processing time per frame and projection device. Results using PI were slightly more accurate, but required on average 5.4 s time per frame. These results are still substantially faster than 2-D to 3-D registration. We conclude that motion backprojection from 2-D motion tracking is an accurate and efficient method for tracking 3-D target motion, but tracking 2-D motion accurately and robustly remains a challenge.

Similar Papers
  • Conference Article
  • Citations6

Evaluation of motion compensation approaches for soft tissue navigation

  • Mar 06, 2008
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jochen Krücker +6
  • PDF
  • Research Article
  • Citations7

Probe versus microscope: a comparison of different methods for image-to-patient registration

  • Jan 01, 2018
  • International Journal of Computer Assisted Radiology and Surgery
  • Martina Perwög +5
  • Research Article
  • Citations31

Robust automatic rigid registration of MRI and X‐ray using external fiducial markers for XFM‐guided interventional procedures

  • Dec 16, 2010
  • Medical Physics
  • Ashvin K George +3
  • Conference Article
  • Citations3

Joint estimation of subject motion and tracer kinetic parameters of dynamic PET data in an EM framework

  • Feb 23, 2012
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Jieqing Jiao +4
  • PDF
  • Research Article
  • Citations28

PCANet-Based Structural Representation for Nonrigid Multimodal Medical Image Registration.

  • May 08, 2018
  • Sensors
  • Xingxing Zhu +4
  • PDF
  • Research Article
  • Citations14

Calibrating 3D Scanner in the Coordinate System of Optical Tracker for Image-To-Patient Registration

  • May 14, 2021
  • Frontiers in Neurorobotics
  • Wenjie Li +7
  • Research Article

A label-aware diffusion model for weakly supervised deformable registration of multimodal MRI-TRUS in prostate cancer.

  • Nov 06, 2025
  • International journal of computer assisted radiology and surgery
  • Zhirong Yao +2
  • Research Article
  • Citations22

Simultaneous 3D-2D image registration and C-arm calibration: Application to endovascular image-guided interventions.

  • Oct 14, 2015
  • Medical physics
  • Uroš Mitrović +3
  • Research Article
  • Citations2

A Multistage Registration Method Using Texture Features

  • Jan 29, 2009
  • Journal of Digital Imaging
  • Andreja Jarc +2
  • Research Article

MP58-06 EVALUATION OF A TOUCH-BASED IMAGE GUIDANCE SYSTEM FOR ROBOTIC PARTIAL NEPHRECTOMY

  • Apr 01, 2023
  • Journal of Urology
  • Shaan Setia +5
  • Book Chapter

Automation of the preoperative image processing steps for ultrasound based navigation

  • Jan 01, 2009
  • Claudia Dekomien +1
  • Conference Article
  • Citations16

Deformable registration for intra-operative cone-beam CT guidance of head and neck surgery

  • Aug 01, 2008
  • Sajendra Nithiananthan +3
  • Research Article
  • Citations1

Image up-sampling method for dual-radiation nondestructive cargo inspection system

  • Jun 17, 2024
  • Nuclear Inst. and Methods in Physics Research, A
  • Hwanhui Jo +2
  • Research Article
  • Citations1

SU-E-I-91: Development of a Compact Radiographic Simulator Using Microsoft Kinect.

  • Jun 01, 2012
  • Medical physics
  • M Ono +7
  • Book Chapter
  • Citations18

Efficient 3D-3D Vascular Registration Based on Multiple Orthogonal 2D Projections

  • Jan 01, 2003
  • Ho-Ming Chan +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.