• Home
  • Search
  • Two Development Concepts of Non-Invasive Oximeters
  • https://doi.org/10.37665/meunrmm99172Copy DOI Icon

Two Development Concepts of Non-Invasive Oximeters

Show More
  • Abstract
  • Literature Map
  • Similar Papers
Abstract

ABSTRACT This paper presents the procedure of designing and implementing a non-invasive, reflective pulse oximeter. Pulse oximeters are measuring the oxygen saturation of blood painlessly, continuously, without destroying the living tissues. They are based on spectroscopic principles, the light sources are usually LEDs, and the photodetector is usually a silicon photodiode. After developing a basic pulse oximeter device, our further research will fork into two threads. The proposed two new devices are unique from many aspects compared to marketed devices. In case of the first thread the connection between the sensor head and the data acquisition unit is wireless and the sensor head is miniaturized, battery powered and body attachable. The data acquisition unit can process the data of more sensor heads placed on the body at the same time. It could help to solve the problem of movement artefacts, which is the greatest problem of today's oximeters. The aim of the other thread is to develop a robust, reflective, inexpensive pulse oximeter. The procedure of the measurement will be simple, it can be used by unskilled people too. The device has on board memory to store and carry the measured values to a doctor by means of a portable flash memory card. This will be a homecare device, which can win the price war in the market. The development of the basic pulse oximeter device is presented in this paper until the almost ready state. For basic research purposes six different reflective measuring heads were developed to study the influences of parameters to the measurement, such as distance between light sources and photodetector, and number of photodetectors. Basic studies for miniaturization and wireless connection are done yet. The concept of the homecare device (e.g. the physical structure, measuring head design, etc.) is wrought now.

Similar Papers
  • Conference Article
  • Citations8

Design Considerations of Small Size Reflective Type Pulse Oximeter Heads in Special Applications

  • Sep 01, 2006
  • Hunor Santha +2
  • Research Article
  • Citations8

Robust Modelling of Reflectance Pulse Oximetry for SpO2 Estimation.

  • Jul 01, 2020
  • Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
  • Sricharan Vijayarangan +4
  • Research Article
  • Citations4

Does the Estimation of Light Attenuation in Tissue Increase the Accuracy of Reflectance Pulse Oximetry at Low Oxygen SaturationsIn Vivo?

  • Sep 01, 2009
  • IEEE Transactions on Biomedical Engineering
  • H Kisch-Wedel +4
  • Research Article
  • Citations28

Performance evaluation of a wrist-worn reflectance pulse oximeter during sleep

  • Jul 09, 2022
  • Sleep Health
  • Hyunjun Jung +6
  • Research Article

Critical discrepancies in oximetry among patients with Raynaud's phenomenon.

  • Oct 12, 2025
  • Clinical rheumatology
  • Roberto Ramos +8
  • Conference Article
  • Citations17

A Reflectance Pulse Oximeter Design Using the MSP430F149

  • May 01, 2007
  • Guowei Di +2
  • Conference Article
  • Citations1

Optical noninvasive calculation of hemoglobin components concentrations and fractional oxygen saturation using a ring-scattering pulse oximeter

  • Jun 18, 2004
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Omar Abdallah +2
  • Research Article
  • Citations11

Measurement of Pulse rate and SPo2 using Pulse Oximeter developed using LabVIEW

  • Jan 01, 2013
  • IOSR Journal of Electrical and Electronics Engineering
  • T.Bheema Lingaiah
  • Research Article
  • Citations60

Ground-Based Sensing System for Cotton Nitrogen Status Determination

  • Jan 01, 2006
  • Transactions of the ASABE
  • R Sui +1
  • Book Chapter

Integrated-Optic Displacement Sensor Using a Pair of Grating Couplers

  • Jan 01, 1995
  • Shogo Ura +2
  • Conference Article

Tunable fiber confocal sensor with LED

  • Jul 17, 2015
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Chun-Jen Weng +5
  • Conference Article
  • Citations5

Liquid sensor based on optical surface plasmon resonance in a dielectric waveguide

  • May 08, 2018
  • Thamer Tabbakh +1
  • Conference Article
  • Citations7

Compact and robust open-loop fiber-optic gyroscope for applications in harsh environments

  • Aug 19, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Behzad M Moslehi +6
  • Conference Article
  • Citations3

A high speed, portable, multi-function, weigh-in-motion (WIM) sensing system and a high performance optical fiber Bragg grating (FBG) demodulator

  • Mar 25, 2010
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Hongtao Zhang +5
  • Research Article
  • Citations23

Impact of hypoxemia on the performance of cerebral oximeter in volunteer subjects.

  • Jul 01, 2000
  • Journal of Neurosurgical Anesthesiology
  • Nitin Shah +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.