• Home
  • Search
  • Accuracy of head motion compensation for the HRRT: Comparison of methods
  • Open Access IconOpen Access
  • Cite Icon13
  • https://doi.org/10.1109/nssmic.2009.5401706Copy DOI Icon

Accuracy of head motion compensation for the HRRT: Comparison of methods

  • Oct 1, 2009
  • Xiao Jin +4 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Motion correction in PET has become more important as system resolution has improved. The purpose of this study was to evaluate the accuracy of three motion compensation methods, event-by-event motion compensation with list-mode reconstruction (MOLAR), frame-based motion correction, and post-reconstruction image registration. Motion compensated image reconstructions were carried out with simulated HRRT data, using a range of motion information based on human motion data. ROI analyses in high contrast regions were performed to evaluate the accuracy of all the motion compensation methods, with particular attention to within-frame motion.Our study showed that MOLAR with list-mode based motion correction using accurate motion data can reliably correct for all reasonable head motions. Over all motions, the average ROI count was within 0.1±4.2% and 0.7±0.9% of the reference, no-motion value for two different ROIs. The location of the ROI centroid was found to be within 0.7±0.3mm of that of the reference image for the raphe nucleus. Frame-based motion compensation and post-reconstruction image registration were able to correct for small (<5mm), but the ROI intensity begins to deteriorate for medium motions (5-10mm), especially for small brain structures such as the raphe nucleus. For large (>10mm) motions, the average centroid locations of the raphe nucleus ROI had an offset error of 1.5±1.8mm and 1.8±1.8mm for each of the frame-based methods. For each frame-based method, the decrease in the average ROI intensity was 16.9±4.3% and 20.2±9.9% respectively for the raphe nucleus, and was 5.5±2.2% and 7.4±0.2% for putamen. Based on these data, we conclude that event-by-event based motion correction works accurately for all reasonable motions, whereas frame-based motion correction is accurate only when the within-frame motion is less than 10mm.

Similar Papers
  • Dissertation

Motion correction of PET for improved image quality

  • Jan 17, 2020
  • The University of Queensland
  • Ashley Gavin Gillman
  • Research Article
  • Citations51

Cardiac motion correction based on partial angle reconstructed images in x‐ray CT

  • May 01, 2015
  • Medical Physics
  • Seungeon Kim +2
  • Research Article
  • Citations55

Reconstruction-Incorporated Respiratory Motion Correction in Clinical Simultaneous PET/MR Imaging for Oncology Applications.

  • Apr 23, 2015
  • Journal of Nuclear Medicine
  • Hadi Fayad +3
  • Research Article
  • Citations31

Quantitative assessment of tumor angiogenesis using real-time motion-compensated contrast-enhanced ultrasound imaging

  • Apr 26, 2012
  • Angiogenesis
  • Marybeth A Pysz +4
  • Research Article
  • Citations41

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.

  • Jan 30, 2015
  • Medical Physics
  • Chuan Huang +6
  • Research Article
  • Citations39

The effect of regularization in motion compensated PET image reconstruction: a realistic numerical 4D simulation study

  • Feb 26, 2013
  • Physics in Medicine and Biology
  • C Tsoumpas +6
  • Conference Article
  • Citations7

A motion compensation technique using sliced blocks and its application to hybrid video coding

  • Jun 24, 2005
  • Satoshi Kondo +1
  • Conference Article
  • Citations3

Wavelet-domain shift invariant motion estimation and compensation

  • Oct 20, 2004
  • Weiting Cai +1
  • Conference Article

Improvement of digital image motion compensation by fuzzy inference

  • Jun 01, 2011
  • Sheng-Che Hsu
  • Research Article
  • Citations17

A fine image motion compensation method for the panoramic TDI CCD camera in remote sensing applications

  • Mar 20, 2013
  • Optics Communications
  • Dejiang Wang +4
  • Conference Article
  • Citations4

Evaluation of two PET motion correction techniques for simultaneous real-time PET-MR acquisitions using an MR-derived motion model

  • Oct 01, 2012
  • Charalampos Tsoumpas +3
  • Research Article
  • Citations3

Motion compensation for aortic valves using partial angle CT reconstructions.

  • Feb 11, 2022
  • Medical Physics
  • Sergej Lebedev +4
  • Research Article
  • Citations11

Motion correction of multi-contrast images applied to T1 and T2 quantification in cardiac MRI

  • Mar 22, 2014
  • Magnetic Resonance Materials in Physics, Biology and Medicine
  • Anne Menini +5
  • Book Chapter

Video Coding

  • Jan 01, 2004
  • Jens-Rainer Ohm
  • Conference Article
  • Citations33

Accuracy of motion correction methods for PET brain imaging

  • Oct 16, 2004
  • R Fulton +8
Cactus Communications logo