• Home
  • Search
  • Accuracy of motion correction methods for PET brain imaging
  • Cite Icon33
  • https://doi.org/10.1109/nssmic.2004.1466823Copy DOI Icon

Accuracy of motion correction methods for PET brain imaging

  • Oct 16, 2004
  • R Fulton +8 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Recently published methods for motion correction in neurological PET include the multiple acquisition frame (MAF) and LOR rebinning methods. The aim of the present work was to compare the accuracy of reconstructions obtained with these methods when multiple, arbitrary movements were applied to a Hoffman brain phantom during 3D list mode acquisition. A reflective target attached to the phantom enabled a Polaris optical motion tracking system to monitor the phantom position and orientation in the scanner coordinate frame. The motion information was used in the motion correction algorithms. The MAF method was applied to the list-mode data after sorting them into a series of dynamic frames, while the LOR rebinning method was applied directly to the list-mode data. A proportion of the list mode events had to be discarded during rebinning because the application of the corrective spatial transformation removed them from the 3D projection space. A correction for these 'lost' events was implemented as a global post-reconstruction scale factor, based on the overall fraction of lost events. Reconstructions from both motion correction methods were compared with a motion-free reference scan of the same phantom. Motion correction produced a marked improvement in image clarity and reduced errors with respect to the reference scan. LOR rebinning with global loss correction was found to be more accurate than the MAF method

Similar Papers
  • Conference Article
  • Citations4

Compensation for head movement in 3D PET

  • Nov 04, 2001
  • R.R Fulton +3
  • Dissertation

Motion correction of PET for improved image quality

  • Jan 17, 2020
  • The University of Queensland
  • Ashley Gavin Gillman
  • Research Article
  • Citations31

Off-line motion correction methods for multi-frame PET data

  • Jan 01, 2009
  • European Journal of Nuclear Medicine and Molecular Imaging
  • Jurgen E M Mourik +4
  • Research Article
  • Citations47

MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects.

  • Mar 08, 2018
  • Journal of Magnetic Resonance Imaging
  • Kevin T Chen +7
  • PDF
  • Research Article
  • Citations13

Comparison of two elastic motion correction approaches for whole-body PET/CT: motion deblurring vs gate-to-gate motion correction

  • Mar 30, 2020
  • EJNMMI Physics
  • Stefanie Pösse +6
  • PDF
  • Research Article
  • Citations36

Automatic Inter-Frame Patient Motion Correction for Dynamic Cardiac PET Using Deep Learning

  • Nov 30, 2021
  • IEEE Transactions on Medical Imaging
  • Luyao Shi +6
  • Research Article
  • Citations18

Spin saturation artifact correction using slice-to-volume registration motion estimates for fMRI time series

  • Jan 10, 2008
  • Medical Physics
  • Roshni Bhagalia +1
  • Research Article
  • Citations16

False fMRI activation after motion correction

  • Jun 05, 2017
  • Human brain mapping
  • Renat Yakupov +3
  • Conference Article
  • Citations13

Accuracy of head motion compensation for the HRRT: Comparison of methods

  • Oct 01, 2009
  • Xiao Jin +4
  • Research Article
  • Citations41

Accelerated acquisition of tagged MRI for cardiac motion correction in simultaneous PET-MR: phantom and patient studies.

  • Jan 30, 2015
  • Medical Physics
  • Chuan Huang +6
  • Research Article
  • Citations3

Motion detection and correction for carotid MRI using a markerless optical system

  • Sep 30, 2022
  • Magnetic Resonance Imaging
  • Jin Liu +9
  • PDF
  • Research Article
  • Citations17

Impact of respiratory motion correction on lesion visibility and quantification in thoracic PET/MR imaging.

  • Jun 04, 2020
  • PLOS ONE
  • Marcel Gratz +5
  • Research Article
  • Citations5

Retrospective Brain Motion Correction in Glutamate Chemical Exchange Saturation Transfer (GluCEST) MRI

  • Apr 15, 2019
  • Molecular Imaging and Biology
  • Dong-Hoon Lee +7
  • Research Article
  • Citations4

Automatic vs manual coronary CT angiography reconstruction for whole-heart coverage CT scanner: a comparison study in general patient population.

  • Jan 18, 2022
  • Journal of X-Ray Science and Technology
  • Cheng Yan +8
  • PDF
  • Research Article
  • Citations16

A Modular Implementation to Handle and Benchmark Drift Correction for High-Density Extracellular Recordings

  • Feb 01, 2024
  • eNeuro
  • Samuel Garcia +5
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.