• Home
  • Search
  • Compensation for head movement in 3D PET
  • Cite Icon4
  • https://doi.org/10.1109/nssmic.2001.1009219Copy DOI Icon

Compensation for head movement in 3D PET

  • Nov 4, 2001
  • R.r Fulton +3 more
Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Motion correction of neurological 3D PET data by the multiple acquisition frame (MAF) method presents some challenges that do not apply to the same extent in 2D. One of the most significant is that 3D PET scans have a much higher scatter component, and the inclusion of valid correction for scatter is essential for accurate quantification. This paper describes a technique for motion correction of PET data acquired in 3D that uses information provided by an optical motion tracking system, and includes corrections for temporal variations in attenuation and scatter. The technique is demonstrated in 3D dynamic and list mode scans of a Hoffman 3D brain phantom performed on a Siemens/CTI ECAT EXACT HR+ scanner in which multiple arbitrary movements were applied to the phantom during data acquisition. The MAF method cannot correct for motion that occurs during the acquisition of an individual frame. The feasibility of avoiding this limitation by acquiring the data in list mode, and re-framing into a dynamic scan in which a new frame is commenced whenever significant motion occurs was investigated. Both approaches provided a major reduction in motion distortion when compared to a conventional reconstruction without motion correction. It appears that effective motion compensation is achievable in 3D neurological PET.

Similar Papers
  • Conference Article

Motion correction of PET data with a joint registration functional for multi-modal data

  • Dec 01, 2012
  • Michael Fieseler +3
  • PDF
  • Research Article
  • Citations17

Impact of respiratory motion correction on lesion visibility and quantification in thoracic PET/MR imaging.

  • Jun 04, 2020
  • PLOS ONE
  • Marcel Gratz +5
  • Conference Article
  • Citations33

Accuracy of motion correction methods for PET brain imaging

  • Oct 16, 2004
  • R Fulton +8
  • Conference Article

A comparison of CT-based attenuation correction strategies for PET data of moving structures

  • Oct 01, 2008
  • Christian Richter +5
  • Conference Article
  • Citations2

Performance of list-mode data acquisition with ECAT EXACT HR positron emission scanner

  • Nov 10, 2002
  • H Watabe +6
  • Research Article
  • Citations1

Validation of regional myocardial blood flow quantification using three-dimensional PET with rubidium-82: repeatability and comparison with two-dimensional PET data acquisition.

  • May 25, 2020
  • Nuclear medicine communications
  • Osamu Manabe +7
  • Conference Article
  • Citations4

Development and evaluation of data-driven respiratory gating methods with simulated list-mode PET data

  • Oct 01, 2015
  • Jizhe Wang +2
  • Research Article
  • Citations1

SU‐GG‐J‐142: Investigation of MIP PET in Motion‐Encompassing Methods to Account for Respiratory Motion in Radiotherapy

  • Jun 01, 2010
  • Medical Physics
  • C Liu +5
  • Research Article
  • Citations42

Sinogram-based motion correction of PET images using optical motion tracking system and list-mode data acquisition

  • Jun 01, 2004
  • IEEE Transactions on Nuclear Science
  • Sang-Keun Woo +6
  • Research Article
  • Citations31

Off-line motion correction methods for multi-frame PET data

  • Jan 01, 2009
  • European Journal of Nuclear Medicine and Molecular Imaging
  • Jurgen E M Mourik +4
  • Conference Article
  • Citations7

Respiratory Motion Correction in 4D PET/CT: Comparison of Implementation Methodologies for Incorporation of Elastic Transformations in the Reconstruction System Matrix

  • Jan 01, 2006
  • F Lamare +7
  • Conference Article
  • Citations4

A fast 3D reconstruction algorithm for inverse-geometry CT based on an exact PET rebinning algorithm

  • Mar 08, 2007
  • Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
  • Samuel R Mazin +1
  • Research Article
  • Citations163

Fast reconstruction of 3D PET data with accurate statistical modeling

  • Jun 01, 1998
  • IEEE Transactions on Nuclear Science
  • C Comtat +4
  • Conference Article
  • Citations10

Image-space 3D scatter correction following list mode acquisition with a large-area positron camera

  • Nov 08, 1998
  • R.J Ott +3
  • Conference Article
  • Citations4

Towards personalized injected patient doses for cardiac perfusion SPECT imaging: A retrospective study

  • Oct 01, 2016
  • P. Hendrik Pretorius +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.