• Home
  • Search
  • Off-line motion correction methods for multi-frame PET data
  • Open Access IconOpen Access
  • Cite Icon31
  • https://doi.org/10.1007/s00259-009-1193-yCopy DOI Icon

Off-line motion correction methods for multi-frame PET data

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

PurposePatient motion during PET acquisition may affect measured time-activity curves, thereby reducing accuracy of tracer kinetic analyses. The aim of the present study was to evaluate different off-line frame-by-frame methods to correct patient motion, which is of particular interest when no optical motion tracking system is available or when older data sets have to be reanalysed.MethodsFour different motion correction methods were evaluated. In the first method attenuation-corrected frames were realigned with the summed image of the first 3 min. The second method was identical, except that non-attenuation-corrected images were used. In the third and fourth methods non-attenuation-corrected images were realigned with standard and cupped transmission images, respectively. Two simulation studies were performed, based on [11C]flumazenil and (R)-[11C]PK11195 data sets, respectively. For both simulation studies different types (rotational, translational) and degrees of motion were added. Simulated PET scans were corrected for motion using all correction methods. The optimal method derived from these simulation studies was used to evaluate two (one with and one without visible movement) clinical data sets of [11C]flumazenil, (R)-[11C]PK11195 and [11C]PIB. For these clinical data sets, the volume of distribution (VT) was derived using Logan analysis and values were compared before and after motion correction.ResultsFor both [11C]flumazenil and (R)-[11C]PK11195 simulation studies, optimal results were obtained when realignment was based on non-attenuation-corrected images. For the clinical data sets motion disappeared visually after motion correction. Regional differences of up to 433% in VT before and after motion correction were found for scans with visible movement. On the other hand, when no visual motion was present in the original data set, overall differences in VT before and after motion correction were <1.5 ± 1.3%.ConclusionFrame-by-frame motion correction using non-attenuation-corrected images improves the accuracy of tracer kinetic analysis compared to non-motion-corrected data.Electronic supplementary materialThe online version of this article (doi:10.1007/s00259-009-1193-y) contains supplementary material, which is available to authorised users.

Similar Papers
  • PDF
  • Research Article
  • Citations17

Impact of respiratory motion correction on lesion visibility and quantification in thoracic PET/MR imaging.

  • Jun 04, 2020
  • PLOS ONE
  • Marcel Gratz +5
  • Research Article
  • Citations47

MR-assisted PET motion correction in simultaneous PET/MRI studies of dementia subjects.

  • Mar 08, 2018
  • Journal of Magnetic Resonance Imaging
  • Kevin T Chen +7
  • PDF
  • Research Article
  • Citations13

Comparison of two elastic motion correction approaches for whole-body PET/CT: motion deblurring vs gate-to-gate motion correction

  • Mar 30, 2020
  • EJNMMI Physics
  • Stefanie Pösse +6
  • Conference Article
  • Citations33

Accuracy of motion correction methods for PET brain imaging

  • Oct 16, 2004
  • R Fulton +8
  • Research Article
  • Citations42

Sinogram-based motion correction of PET images using optical motion tracking system and list-mode data acquisition

  • Jun 01, 2004
  • IEEE Transactions on Nuclear Science
  • Sang-Keun Woo +6
  • Dissertation

Motion correction of PET for improved image quality

  • Jan 17, 2020
  • The University of Queensland
  • Ashley Gavin Gillman
  • Research Article
  • Citations18

Spin saturation artifact correction using slice-to-volume registration motion estimates for fMRI time series

  • Jan 10, 2008
  • Medical Physics
  • Roshni Bhagalia +1
  • Conference Article

Deep Learning Denoising in Histo-Projection TOF Data Non-Rigid Motion Estimation and Correction

  • Oct 16, 2021
  • Eva E Panin +2
  • Research Article
  • Citations40

Non-rigid dual respiratory and cardiac motion correction methods after, during, and before image reconstruction for 4D cardiac PET

  • Dec 01, 2015
  • Physics in Medicine & Biology
  • Tao Feng +3
  • Conference Article

A new approach in patient motion correction for cardiac SPECT: A simulation study

  • Oct 01, 2009
  • T Hughes +2
  • Research Article
  • Citations74

Tracer kinetic model-driven registration for dynamic contrast-enhanced MRI time-series data.

  • Oct 29, 2007
  • Magnetic Resonance in Medicine
  • Giovanni A Buonaccorsi +10
  • Conference Article
  • Citations4

Compensation for head movement in 3D PET

  • Nov 04, 2001
  • R.R Fulton +3
  • Research Article
  • Citations8

Cancer Radiomic and Perfusion Imaging Automated Framework: Validation on Musculoskeletal Tumors.

  • Mar 01, 2024
  • JCO clinical cancer informatics
  • Elvis Duran Sierra +7
  • Research Article
  • Citations18

Hybrid PET-MRI Applications in Movement Disorders.

  • Nov 08, 2018
  • International review of neurobiology
  • Giacomo Tondo +5
  • PDF
  • Research Article
  • Citations4

Reidentification of Participants in Shared Clinical Data Sets: Experimental Study

  • Mar 15, 2024
  • JMIR AI
  • Daniela Wiepert +6
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.