• Home
  • Search
  • The effect of regularization in motion compensated PET image reconstruction: a realistic numerical 4D simulation study
  • Cite Icon39
  • https://doi.org/10.1088/0031-9155/58/6/1759Copy DOI Icon

The effect of regularization in motion compensated PET image reconstruction: a realistic numerical 4D simulation study

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

Following continuous improvement in PET spatial resolution, respiratory motion correction has become an important task. Two of the most common approaches that utilize all detected PET events to motion-correct PET data are the reconstruct-transform-average method (RTA) and motion-compensated image reconstruction (MCIR). In RTA, separate images are reconstructed for each respiratory frame, subsequently transformed to one reference frame and finally averaged to produce a motion-corrected image. In MCIR, the projection data from all frames are reconstructed by including motion information in the system matrix so that a motion-corrected image is reconstructed directly. Previous theoretical analyses have explained why MCIR is expected to outperform RTA. It has been suggested that MCIR creates less noise than RTA because the images for each separate respiratory frame will be severely affected by noise. However, recent investigations have shown that in the unregularized case RTA images can have fewer noise artefacts, while MCIR images are more quantitatively accurate but have the common salt-and-pepper noise. In this paper, we perform a realistic numerical 4D simulation study to compare the advantages gained by including regularization within reconstruction for RTA and MCIR, in particular using the median-root-prior incorporated in the ordered subsets maximum a posteriori one-step-late algorithm. In this investigation we have demonstrated that MCIR with proper regularization parameters reconstructs lesions with less bias and root mean square error and similar CNR and standard deviation to regularized RTA. This finding is reproducible for a variety of noise levels (25, 50, 100 million counts), lesion sizes (8 mm, 14 mm diameter) and iterations. Nevertheless, regularized RTA can also be a practical solution for motion compensation as a proper level of regularization reduces both bias and mean square error.

Similar Papers
  • Conference Article
  • Citations4

Evaluation of two PET motion correction techniques for simultaneous real-time PET-MR acquisitions using an MR-derived motion model

  • Oct 01, 2012
  • Charalampos Tsoumpas +3
  • Research Article
  • Citations51

Cardiac motion correction based on partial angle reconstructed images in x‐ray CT

  • May 01, 2015
  • Medical Physics
  • Seungeon Kim +2
  • Research Article
  • Citations13

Respiratory- and cardiac motion-corrected simultaneous whole-heart PET and dual phase coronary MR angiography.

  • Oct 15, 2018
  • Magnetic resonance in medicine
  • Camila Munoz +5
  • Research Article

Deep learning based motion correction in ultrasound microvessel imaging approach improves thyroid nodule classification

  • May 30, 2025
  • Scientific Reports
  • Manali Saini +3
  • PDF
  • Research Article
  • Citations17

Impact of respiratory motion correction on lesion visibility and quantification in thoracic PET/MR imaging.

  • Jun 04, 2020
  • PLOS ONE
  • Marcel Gratz +5
  • Research Article
  • Citations3

Quantitative Evaluation of PET Respiratory Motion Correction Using MR Derived Simulated Data

  • Dec 01, 2015
  • IEEE Transactions on Nuclear Science
  • Irene Polycarpou +3
  • PDF
  • Research Article
  • Citations16

Downscaling and validating SMAP soil moisture using a machine learning algorithm over the Awash River basin, Ethiopia.

  • Jan 13, 2023
  • PLOS ONE
  • Shimelis Sishah +4
  • Conference Article
  • Citations13

Accuracy of head motion compensation for the HRRT: Comparison of methods

  • Oct 01, 2009
  • Xiao Jin +4
  • Research Article
  • Citations41

Non-Rigid Event-by-Event Continuous Respiratory Motion Compensated List-Mode Reconstruction for PET.

  • Oct 10, 2017
  • IEEE Transactions on Medical Imaging
  • Chung Chan +6
  • Conference Article

Coupled motion and activity estimation from PET and MR data with motion model-based parameter reduction

  • Oct 01, 2015
  • Daniel R Balfour +4
  • Research Article

TH-E-110-08: Free Breathing Hepatic CT Perfusion with Automatic a Posteriori Motion Correction

  • Jun 01, 2011
  • Medical Physics
  • N Jensen +7
  • Research Article
  • Citations3

Motion detection and correction for carotid MRI using a markerless optical system

  • Sep 30, 2022
  • Magnetic Resonance Imaging
  • Jin Liu +9
  • PDF
  • Research Article
  • Citations5

Improved [18F]FDG PET/CT Diagnostic Accuracy for Infective Endocarditis Using Conventional Cardiac Gating or Combined Cardiac and Respiratory Motion Correction (CardioFreezeTM)

  • Oct 07, 2023
  • Diagnostics
  • D Ten Hove +4
  • Research Article
  • Citations9

Cardiac motion correction with a deep learning network for perfusion defect assessment in single-photon emission computed tomography myocardial perfusion imaging

  • Nov 02, 2024
  • Journal of Nuclear Cardiology
  • Xirang Zhang +4
  • Research Article
  • Citations45

Pilot tone-based motion correction for prospective respiratory compensated cardiac cine MRI.

  • Nov 23, 2020
  • Magnetic Resonance in Medicine
  • Juliane Ludwig +4
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.