• Home
  • Search
  • An Optimization-Based Approach to the Multiple Static Delivery Technique in Radiation Therapy
  • Cite Icon22
  • https://doi.org/10.1023/a:1022942825680Copy DOI Icon

An Optimization-Based Approach to the Multiple Static Delivery Technique in Radiation Therapy

Show More
  • Abstract
  • Literature Map
  • References
  • Citations
  • Similar Papers
Abstract

The paper considers the intensity modulated radiation therapy (inverse) treatment planning. An approach to determine the trajectories of the leaves of the multileaf collimator (MLC) in order to produce the prescribed intensity distribution is developed. The paper concentrates on the multiple static delivery technique. A mathematical model for calculating the intensity distribution with the help of locations of the leafheads of subsequent subfields is constructed. Furthermore, an optimization model in which the decision variables are the locations of leafheads is developed. The relevant constraints are considered as well. The optimization problem is a large dimensional constrained nonlinear global extremum problem. It is solved by the LGO (Lipschitz (Continuous) Global Optimizer) program system. Comparisons with other optimization method (Hooke–Jeeves iteration) are included. Numerical experiments are presented to confirm the functionality of the method.

Similar Papers
  • Research Article
  • Citations3

A multileaf collimator phantom for the quality assurance of radiation therapy planning systems and CT simulators

  • Nov 01, 2004
  • International Journal of Radiation OncologyBiologyPhysics
  • A Mcniven +2
  • Research Article
  • Citations15

Comparing dose in the build‐up region between compensator‐ and MLC‐based IMRT

  • Sep 01, 2012
  • Journal of Applied Clinical Medical Physics
  • Khosrow Javedan +4
  • Abstract
  • Citations1

Correlation of Integral Dose, White Blood Cell Counts, and Radiation Therapy Techniques for Head and Neck Cancer Patients Under Radiation Therapy

  • Sep 01, 2014
  • International Journal of Radiation Oncology*Biology*Physics
  • A Al-Basheer +8
  • PDF
  • Research Article
  • Citations9

Dosimetric evaluation study of IMRT and VMAT techniques for prostate cancer based on different multileaf collimator designs

  • Dec 28, 2022
  • Radiation and Environmental Biophysics
  • Mohamed M Fathy +3
  • Research Article
  • Citations46

Intensity modulated radiation therapy with multileaf collimators of different leaf widths: a comparison of achievable dose distributions

  • Apr 01, 2005
  • Radiotherapy and Oncology
  • Simeon Nill +3
  • Research Article
  • Citations13

Effect of MLC leaf width on treatment adaptation and accuracy for concurrent irradiation of prostate and pelvic lymph nodes

  • May 06, 2013
  • Medical Physics
  • Qingyang Shang +3
  • Discussion

Editorial Comment to Therapeutic outcomes of neoadjuvant and concurrent androgen-deprivation therapy and intensity-modulated radiation therapy with gold marker implantation for intermediate and high-risk prostate cancer.

  • Feb 17, 2015
  • International journal of urology : official journal of the Japanese Urological Association
  • Yasuo Yoshioka
  • Research Article
  • Citations120

On the sensitivity of patient‐specific IMRT QA to MLC positioning errors

  • Feb 05, 2009
  • Journal of Applied Clinical Medical Physics
  • Guanghua Yan +5
  • Research Article

Advantages and disadvantages of removed flattening filter Linac: A Monte Carlo study on full quantitative dosimetric data of 18 MV-Varian Linac

  • Dec 01, 2018
  • Iranian Journal of Medical Physics
  • Mansour Zabihzadeh +3
  • Research Article
  • Citations2

Trends in Radiation Dose and Technique For Anal Canal Squamous Cell Carcinoma.

  • Jun 01, 2019
  • American Journal of Clinical Oncology
  • Rodney E Wegner +8
  • Research Article
  • Citations1

Dosimetric effect of multi-leaf collimator transmission on intensity-modulated radiation therapy

  • Mar 15, 2013
  • Chinese Journal of Radiation Oncology
  • Ruijie Yang +3
  • Conference Article

Analysis of small beamlets for IMRT using radiochromic films

  • Jul 23, 2000
  • J.W Sohn +5
  • Research Article

SU-FF-T-249: Quality Assurance of Intensity Modulated Beam Using MatriXX

  • Jun 01, 2009
  • Medical Physics
  • A Tyagi +1
  • Research Article
  • Citations41

Comprehensive fluence model for absolute portal dose image prediction

  • Mar 26, 2009
  • Medical Physics
  • K Chytyk +1
  • Research Article

TU‐A‐AUD A‐01: LINAC and MLC QA for IMRT

  • Jun 01, 2008
  • Medical Physics
  • T Losasso +1
Cactus Communications logo

Copyright 2026 Cactus Communications. All rights reserved.